MANUFACTURER'S GUARANTEE
The manufacturer's guarantee operates for TEN YEARS following the date of purchase.
In the unlikely event of SCALEWATCHER™ becoming unserviceable, i.e. the green
light fails to illuminate, send the unit back for replacement, quoting date of purchase and
serial number. This guarantee does not extend to any other electrical or water appliance
or device that may be in use by the user of SCALEWATCHER™ and we accept no
liability for the malfunction of any device other than SCALEWATCHER™, which has,
either directly or indirectly been sold to the user. SCALEWATCHER™ does not a ect
the potability or the natural mineral content of the water, as there is nothing in contact
with the water. Therefore, we accept no responsibility for water quality.
These guarantees shall only remain valid provided that the product is used for the
precise purpose that it was designed and manufactured and provided that it is installed
and in strict accordance with the appropriate instructions.

WARNINGS

Do not immerse in water.
Removing the back plate will void the Warranty and Performance Guarantee.
SCALEWATCHER™ treated water reverts to its original state after 48 hours. This means that
the water sitting in your water heater for several days will tend to behave as untreated water
causing those nasty hard water stains. After the existing water has been replaced by freshly
treated water, the anti-scaling effects of SCALEWATCHER™ will be noticeable again. If you
plan to keep taking frequent long periods of absence, not using your hot water, we recommend
installing a supplemental treatment unit on the outlet of the water heater.
Do not dismantle your existing water softener before you are fully satisfied.

Technical specifications

Supply voltage: 110 – 240 VAC + 10 %, 50/60 Hz
Energy consumption Less than 8 Watt/hour
Power supply External Adaptor, UL/CSA approved
Application Voltage 12 VDC
Coil cable 18AWG stranded, White
Maximum Coil Temperature 200 °F
Capable of driving 2 coils double stacked
Output Reading Bar graph
Enclosure material ABS, Grey
Maximum enclosure temperature 166 °F
Minimum enclosure temperature 40 °F
Protection rate Nema 2
Dimension unpacked (LxWxH) 9.5"x6"x1.5"
Dimension packed (LxWxH): 14"x7"x3"
Weight packed Maximum 3.3 lbs