Astronomical/annual time switch

Advertisement

9
Control input with delaytime
The control signal affects only channel 1 and overrides all program settings for this channel (OR function). Channel 1 remains switched on as
along as the control signal is present.
When the control signal is switched off, the output of channel 1 switches off after the defined delaytime, unless one of the programs for this
channel specifies otherwise.
Setting the delaytime
Changing the lithium battery module
Important note:
If the battery is replaced with the supply voltage connected, all stored program data are retained. If the battery is replaced
with the supply voltage disconnected, the date and time must be set again. Notes for disposal of the lithium battery:
Dispose of the exhausted battery in accordance with your local regulations. Make sure the battery is fully discharged before disposal.
If the function CYCLE is selected under SETUP, channel 1 is switched on and off cyclically.
Control input
Switched output
0 ... 23h 59min 59s
Delaytime
0 ... 23h 59min 59s