Functional Description; Specifications - Milwaukee REDSTICK MLDIG14 Operator's Manual

Digital level with pinpoint measurement technology
Hide thumbs Also See for REDSTICK MLDIG14:
Table of Contents

Advertisement

Available languages

Available languages

1
2
12
11
13
1. Removable End Cap
2. Hanghole*
3. Main Display
4. Top Read Display
5. Control Panel
6. Up Arrow
7. Menu/Select Button
*Not featured on MLDIG14

SPECIFICATIONS

Cat. No. ................................MLDIG14, MLDIG24,
Electronic Module Accuracy .. ± 0.03° at 0° and 90°
Recommended Ambient
Operating Temperature ....................14°F to 122°F
Storage Temperature Range ............. -4°F to 158°F
Charging Temperature Range ...........32°F to 140°F
Operating Life ...................................up to 10 hours
Ingress Protection............................................ IP65
Battery Cat. No. ...................................48-11-2130
Volts ................................................................ 4 DC
Operating Temperature
Battery and Charger .......................40°F to 104°F
Battery and Tool .............................. -4°F to 140°F
Power Supply Cat. No. .......................48-59-1202

FUNCTIONAL DESCRIPTION

3
14
15
MLDIG48, MLDIG72
± 0.1° between 0° and 90°
(4°C to 40°C)
(-20°C to 60°C)
4
5
6
7
8
To reduce the risk of fire, personal
WARNING
injury, and product damage due to
a short circuit, never immerse your tool, battery
pack or charger in fluid or allow a fluid to flow
inside them. Corrosive or conductive fluids, such
as seawater, certain industrial chemicals, and
bleach or bleach containing products, etc., can
cause a short circuit.
Maintenance and Storage
Do not expose your battery or cordless tools to water
or rain, or allow them to get wet. This could damage
the tool and battery. Do not use oil or solvents to
clean or lubricate your battery. The plastic casing
will become brittle and crack, causing a risk of injury.
Store batteries at room temperature away from mois-
ture. Do not store in damp locations where corrosion
of terminals may occur. As with other battery types,
permanent capacity loss can result if the pack is
stored for long periods of time at high temperatures
(over 120° F). MILWAUKEE Li-Ion batteries maintain
their charge during storage longer than other battery
types. After about a year of storage, charge the bat-
tery as normal.
3
9
10
8. Down Arrow
9. Power Button
10. PIN Button
11. Wall Plug
12. USB Cable
13. Wall Grip
14. USB Port
15. Battery Door
BATTERY

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Redstick mldig24Redstick mldig48Redstick mldig72

Table of Contents