  • Page 1 4 ANALOG OUTPUTS MODULE S4AO USERS MANUAL...
  • Page 3: Table Of Contents

    6. SERIAL INTERFACES ............31 6.1 rs-485intErfaCEs – list of paraMEtErs .......31 6.2 usb intErfaCE – list of paraMEtErs ........32 6.3 Map of s4ao MoDulE rEgistErs..........32 7. BEFORE DECLARING A DAMAGE ........... 50 8. SOFTWARE UPDATE ............51 9. TECHNICAL DATA ............53...
  • Page 5: Application

    The module setting can be done through USB or one of the RS-485 interface using the available for free eCon program. The S4AO module performs the following functions: • analog output (current and / or voltage, according to the or- dering code), • 2 independent interfaces RS-485 Modbus.
  • Page 6: Module Set

    Figure 1: View of the S4AO module 2. MODULE SET Complete set of the meter includes: • S4AO ........... 1 pc • user’s manual ......1 pc • guarantee card ......1 pc...
  • Page 7: Basic Requirements, Operational Safety

    3. BASIC REQUIREMENTS, OPERATIONAL SAFETY The symbols in the manual mean: • Warning! Warning of potentially hazardous situations. Especially important to be aware of before connecting the device. Failure to follow the direc- tions marked by this symbol could result in serious injuries of the personnel and damage of the device.
  • Page 8: Installation

    RS-485 communications. 4. INSTALLATION 4.1. Mounting The S4AO module can be installed in modular distribu- tion devices on the 35 mm rail bracket. The module enclosure is made of plastic and its dimensions are 53 x 110 x 60.5 mm.
  • Page 9 Figure 2: Module dimensions...
  • Page 10: External Connection Diagrams

    4.2. External Connection Diagrams The module connections are shown in Figure 3. The polarization of the power supply is not needed when the module is supplied by a d.c. voltage. Figure 3: Electrical connections of the S4AO module.
  • Page 11 2 set of 1 voltage + 1 current outputs version Legend: POWER RS-485 RS-485 SUPPLY PORT 1 PORT 2 300 V isolation AO 1 AO 3 AO 2 AO 4 50 V isolation Figure 4: Isolation scheme of the S4AO module.
  • Page 12: Lateral Bus

    Table 1: LED description Description ON / ERROR - Light continuously in green: normal operation, (green / red) - Blink alternatively in green / red: short-circuit detected on one or several voltage outputs. - Light continuously in red: power supply unplug- ged (self-powered by USB) or error, - Blink in red: calibration error Rx 1 (green)
  • Page 13: Operation

    (Table 4: 4000 Modbus registers) and the device must be powered. 5.2. Slave operations In order to use the S4AO module as a Slave device on a RS-485 interface, it has to be configured as follow: • RS-485 port 1 mode (register 4010). (or RS-485 port 2 mode (register 4017)) set to ‚0’...
  • Page 14: Master Operations

    5.3. Master operations In order to use the S4AO module as a Slave device on a RS-485 interface, it has to be configured as follow: • RS-485 port 1 mode (register 4010). (or RS-485 port 1 mode.(register 4017)) set to ‚1’ (Master), set transmission...
  • Page 15: Cooperation With Other Devices (Lateral Bus)

    5.4. Cooperation with other devices (lateral bus) Once the traps opened (see chapter 4.3. Lateral bus on page 7), the S4AO can be connected to to others LUMEL devices which are also equipped by a lateral bus. All devices can be RS-485 and the Master is connected at an extremity, or one device is set as RS-485 Master and monitors others devices.
  • Page 16: Counters

    5.5 Counters In all version, each output is monitored by 2 counters: one which is incremented on each second if the output value is below a defined level (4104, 4106, 4108 and 4110), and a second which is incremented on each second if the output value is upper a defined level(4105, 4107, 4109 and 4111).
  • Page 17 high value counter low value counter Figure 7: High / low value timers thresholds...
  • Page 18: Individual Characteristic

    It is used for imaging the measurements coming from third Slave device to a standard value which can be ge- nerated by the S4AO module. The conversion is done by an approximation of a straight line passing through the characteri- stic parameters points.
  • Page 19: Short Circuits

    4158 registers. It is disabled when a ‚0’ is set. When enabled, a timer is reset after updating (by an external Modbus Master or when S4AO is set as RS-485 Master). When the counter rea- ches the set timeout, it switches automatically the output to its...
  • Page 20 4112 to 4115 registers. When S4AO is set to Modbus Master, it is important to set the timeout according to the number of channel to control and to the scan parameters (registers 4013 and 4014 for Port 1, registers 4020 and 4021 for Port 2).
  • Page 21 channel 1 channel 1 channel 4 channel 3 channel 3 channel 2 channel 4 channel 2 channel 1 channel 1 receive send send send receive receive receive send send receive RS-485 RS-485 RS-485 RS-485 RS-485 RS-485 RS-485 RS-485 RS-485 RS-485 request reply request...
  • Page 22 320000 Transmission time [ms] = (baudrate [bps]) response timeout [ms] = Slave [ms] + Transmission time [ms] timeout Amalog output Timeout Number of channels to scan (Number of tolerated unreply +1) (scanning period + response timeout + transmission time) Always round your results to the upper value. For example, if you calculate a value equal to 811 ms, enter “9”...
  • Page 23: Device Configuration Using E-Con Program

    Figure 12: e-Con program window The e-Con program designed for configuration of the S4AO module is available at the manufacturer’s website (www.lumel.com.pl) for free. The module should be connected to a PC via USB cable or one of the RS-485 interface. When the e-Con program starts, select the port on which the device is installed in the area “Communication”, set the transmission...
  • Page 24 Saving the configuration to a file about the Reading the configuration from module Saving the configuration to a meter Reading the configuration from a mete Figure 13: Read, write and export settings connect / disconnect Figure 14: Establishing connection to S4AO module...
  • Page 25: Configuration Parameters

    5.9.1 Configuration parameters After establishing a connection, there are configuration parameters of the module on the right side of the program window. Table 2: eCon configuration parameters Parameter name Parameter description Range of Manu- parameter facturer change setting External RS-485 tab Mode Choice of the external Slave/Master...
  • Page 26 Internal RS-485 tab Mode Choice of the internal Slave / Master Slave RS-485 (Port 1) operation mode: Slave or Master Transmission Choice of the internal RS- mode 485 (Port 1) transmission mode Baud rate Choice of the baud rate of 1 200 9 600 the internal RS-485 (Port...
  • Page 27 Low value timer When the analog output 0.00 – 24.00 0.00 threshold is lower that this value, mA (current) the corresponding counter is incremented on each 0.00 – 12.00 V second. (voltage) High value timer When the analog output 0.00 – 24.00 0.00 –...
  • Page 28 Modbus function Master mode only. Set the 3...4 Modbus function to use to read the Slave device. Data type Master mode only. Set the char 8 char 8 type of data to read on the uchar 8 short 16 Slave. ushort 16 long 32 ulong 32...
  • Page 29: Status Value

    Device status This tab is used to show on one window the parameters of the S4AO. Status values This window show the current voltage / current value at the outputs, the value read by RS-485 Master (if enabled) and allow also to update manually each output.
  • Page 30: Configured Values

    5.9.3 Configured values Figure 16: eCon: configured values...
  • Page 31: Serial Interfaces

    6. SERIAL INTERFACES 6.1. RS-485 Interfaces – list of parameters Both RS-485 interfaces (Port 1 and Port 2) are intended for the configuration and the operations of the module. • identifier 215 (0xD7) • device address 1...247 • baud rate 1,2, 2,4, 4,8, 9,6, 19,2, 38,4, 57,6, 115,2 kbit/s • transmission mode...
  • Page 32: Usb Interface - List Of Parameters

    Broadcast address: 253 6.3 Map of S4AO module registers In the S4AO module, data are placed in 16 and 32-bit registers. Process variables and module parameters are placed in the address area of registers in a way depended on the variable...
  • Page 33 significant to the most significant bit (b0-b15). The 32-bit regi- sters contain float numbers compliant with IEEE-754 standard. Range of the registers is shown in Table 3. The 16-bit registers are shown in Table 4 and Table 5. The 2x16-bits registers with their 32-bit equivalent registers are shown in Table 6.
  • Page 34 Table 4: 4000 Modbus registers Read/ Register Range Description Default address Write 4000 0xD7 Device identifier 0xD7 4001 1...3 Output signals: 1: 4 current, 2: 4 voltage, 3: 2 set of 1 voltage + 1 current 4002 Software version 4003 Bootloader version 4004 Serial number (MSB)
  • Page 35 4013 1...50 Port 1 Modbus Master RS-485. Przekroczenie limitu czasu urzą- dzeń Slave (ms*100) 4014 Port 1 Modbus Master RS-485: 1...30000 Okres skanowania urządzeń Slave (ms*100) 4015 1...247 Port 1 adres Modbus Slave RS-485 4016 0...1 Port 1 aktualizacja parametrów RS-485 4017 0...1...
  • Page 36 Table 5: 4100 Modbus registers Read/ Register Range Description Default address Write 4100 Analog Output 1 value *100 4101 Analog Output 2 value *100 4102 Analog Output 3 value *100 4103 Analog Output 4 value *100 4104 Analog Output 1 low value *100: threshold to start the AO1 low value timer (6080/6082) 4105...
  • Page 37 4112 Analog output 1: Output value in case of timeout. If S4AO is Master, AO1 will take this value after value specified in AO1_timeout without slave communication. If S4AO is Slave, AO1 will take this value after a specified time without write.
  • Page 38 4119 -32768 Analog output 1, expected value … for individual characteristic, point 32767 1 (x 100) 4120 -32768 Analog output 2, input of indivi- … dual characteristic of value read 32767 through RS-485, point 0 4121 -32768 Analog output 2, expected value …...
  • Page 39 4131 -32768 Wyjście analogowe 4, wartość … oczekiwana charakterystyki indy- 32767 widualnej, punkt 1 (x 100) 4132 0...2 Analog output 1 mode. 0: No Master control 1: read out through Port 1 RS-485 2: read out through Port 2 RS-485 4133 0...2 Analog output 2 mode.
  • Page 40 4141 0...12 Analog output 1, Modbus Master: Slave data type. 0: char 8 1: uchar 8 2: short 16 3: ushort 16 4: long 32 5: ulong 32 6: float 32 7: float 2x16 8: swapped float 2x16 9: long 2x16 10: swapped long 2x16 11: ulong 2x16 12: u swapped long 2x16...
  • Page 41 4147 0...12 Analog output 2, Modbus Master: Slave data type. 0: char 8 1: uchar 8 2: short 16 3: ushort 16 4: long 32 5: ulong 32 6: float 32 7: float 2x16 8: swapped float 2x16 9: long 2x16 10: swapped long 2x16 11: ulong 2x16 12: u swapped long 2x16...
  • Page 42 4153 0...12 Analog output 3, Modbus Master: Slave data type. 0: char 8 1: uchar 8 2: short 16 3: ushort 16 4: long 32 5: ulong 32 6: float 32 7: float 2x16 8: swapped float 2x16 9: long 2x16 10: swapped long 2x16 11: ulong 2x16 12: u swapped long 2x16...
  • Page 43 4160 Short circuit detected on analog outputs 1 and / or 2 *** 4161 Short circuit detected on analog outputs 3 and / or 4 *** 4162 Analog output 1: reset the low value timer 4163 Analog output 1: reset the high value timer 4164 Analog output 2: reset the low...
  • Page 44 Table 6: Floats Modbus registers Description Unit 6000/7000 7600 Analog output 1 Master mode. Read value from external device 6002/7002 7601 Analog output 2 Master mode. Read value from external device 6004/7004 7602 Analog output 3 Master mode. Read value from external device 6006/7006 7603 Analog output 4 Master mode.
  • Page 45 6032/7032 7616 Analog output 1: Output value in V / mA * case of timeout. If S4AO is Master, AO1 will take this value after va- lue specified in 4112 without slave communication. If S4AO is Slave, AO1 will take this value if the ana- log output 1 is not update after this timeout.
  • Page 46 6038/7038 7619 Analog output 4: Output value in V / mA * case of timeout. If S4AO is Master, AO4 will take this value after va- lue specified in 4115 without slave communication. If S4AO is Slave, AO4 will take this value if the ana- log output 1 is not update after this timeout.
  • Page 47 6062/7062 7631 Analog output 3, expected value for individual characteristic, point 1 6064/7064 7632 Analog output 4, input of indivi- dual characteristic of value read through RS-485, point 0 6066/7066 7633 Analog output 4, expected value for individual characteristic, point 0 6068/7068 7634 Analog output 4, input of indivi-...
  • Page 48 6084/7084 7642 Analog output 1: time during which s * 1 000 000 the analog output issued a signal upper than specified in the 4105 register (value incremented after 6086/7286overflows) 6086/7086 7643 Analog output 1: time during which the analog output issued a signal upper than specified in the 4105 register (value up to 999 999) 6088/7088...
  • Page 49 6100/7100 7650 Analog output 3: time during which s * 1 000 000 the analog output issued a signal upper than specified in the 4109 register (value incremented after 6102/7102 overflows) 6102/7102 7651 Analog output 3: time during which the analog output issued a signal upper than specified in the 4109 register (value up to 1 000 000) 6104/7104...
  • Page 50: Before Declaring A Damage

    7. BEFORE DECLARING A DAMAGE The following table must be checked in case of incorrect symptoms: Table 7: Error description Symptom Procedure Remarks The ON / ERROR led is Check the connection of not lightning the power supply cable The ON / ERROR led Check the connection of The module can be is continuously red...
  • Page 51: Software Update

    8. SOFTWARE UPDATE The features implemented in the S4AO module enable to upgra- de its software using a PC with e-Con software installed. Free e-Con software and the update files are available at the website www.lumel.com.pl. Updating is done via the external RS-485 in- terface, so the module must be powered.
  • Page 52 […] button. If the correct file is selected, the LU program will display a message File opened. Press Send button. The LU program shows a progress bar and the S4AO will blink with green diode during the software update. The module restarts, restores the manufacturer settings and goes to normal operation after the upgrade process is successfully completed.
  • Page 53: Technical Data

    9. TECHNICAL DATA Output values ranges: Current output programmable: current (maximal range) 0...20...24 mA or 3.75...4...20...24 mA load resistance: 0...500 Ω disposable voltage: 15 V basic error: 0.2 % of range resolution: 0.05 % of range Voltage output programmable: voltage (maximal range) 0...10...12 V load resistance: > 500 Ω disposable voltage: 15 V basic error: 0.2 % of range resolution: 0.1 % of range...
  • Page 54 USB for configuration: 1.1 / 2.0; address: all; mode: all; baud rate: all; maximal USB wire length: 3m broadcasting address: 253 transmission mode: Modbus RTU max time to start response: 400 ms (read) 1 000 ms (write) Counters resolution: ± 1s on each launch Pulses which hold less than 1 s can be uncounted Test voltages:...
  • Page 55 Protection grade IP: from frontal side IP 50 from terminals IP 00 Power input in the supply circuit: ≤ 7 VA Weight < 0.2 kg Overall dimensions 53 x 110 x 60 mm Rated operating conditions: - supply voltage 85...253 V a.c. 40..400 Hz; 90...300 V d.c. 20...40 V a.c. 40..400 Hz; 20...60 V d.c. - ambient temperature -10 ...
  • Page 56: Ordering Code

    10. ORDERING CODE Table 8: Ordering code X XX X 2 analog outputs module S4AO - Outputs: 4 current outputs, 0/4...20 mA 4 voltage outputs, 0...10 V 2 sets of 1 voltage + 1 current output: 0...10 V and 0/4...20mA acc.to customer’s requirements*...
  • Page 57 00 - standard version E - English version, 0 - without extra quality requirements. AVAILABLE ACCESSORIES: Accessories: For the S4AO module, you can order: • lateral bus inter-module connector; Order code -069-00-00150, • lateral bus to cable connector; Order code 24-171-01-00017,...
  • Page 58 • USB CABLE A/miniUSB-B - 1m BLACK; Order code24-171-01-00016...
  • Page 60 LUMEL S.A. ul. Słubicka 1, 65-127 Zielona Góra, POLAND tel.: +48 68 45 75 100, fax +48 68 45 75 508 www.lumel.com.pl, e-mail: lumel@lumel.com.pl Export department: tel.: (+48 68) 45 75 139, 45 75 233, 45 75 321, 45 75 386 fax.: (+48 68) 32 54 091...