Fujitsu Lifestyle Series Operating Manual page 15

Wall mounted type
Table of Contents

Advertisement

■ State of indicator lamps
: The instruction is relating to the wireless LAN control
(optional).
Lighting pattern:
Off,
On,
State
Causes and solutions
Automatic defrosting operation
⇒ Please wait until finishing the defrosting
(maximum of 15 minutes).
Filter indicator
⇒ Clean the air filter and reset the filter
sign.
(3 times)
Demand response operation
(Twice)
Error code display
⇒ Consult authorized service personnel.
(Fast)
Timer setting error because of Auto restart
⇒ Reset the clock and timer settings.
Test run operation (for authorized
personnel only)
⇒ Press
The power to the wireless router is
not on.
⇒ Check that the power to the wireless
router is on.
(Slow)
There is a possibility that the W-LAN
adapter is not properly connected to
the wireless router.
⇒ Disconnect the power supply to the air
conditioner (via breaker or plug), and
then re-connect.
The software of the W-LAN adapter
is being updated.
During the air conditioner registration
(pairing of W-LAN adapter)
Restricted function
■ Manual Auto operation and Filter indicator
reset
You can operate the air conditioner with
indoor unit.
Status
Length of pressing down Mode or operation
In operation More than 3 seconds
Stopping
2 seconds or less
More than 3 seconds and
less than 10 seconds
More than 10 seconds
(Only for servicing.*)
*:To stop the forced cooling, press this button or
controller.
Blinking,
Any state
to quit the test run.
on the
Stop
Filter indicator reset
Auto
Forced cooling
on the remote
See
page
10
10
7
-
10
3
-
11
-
12
11
En-14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Astg24kmtcAstg18kmtcHalcyon asug09-12lmas

Table of Contents