Kohler 15CCO Service Manual page 84

Commercial & recreational mobile generator sets
Table of Contents

Advertisement

WARNING
Sulfuric acid in batteries.
Can cause severe injury or death.
Wear
protective
clothing.
Battery acid may cause
blindness and burn skin.
Battery electrolyte is a diluted sulfuric acid. Battery acid
can cause severe injury or death. Battery acid can cause
blindness and burn skin. Always wear splashproof safety
goggles, rubber gloves, and boots when servicing the battery.
Do not open a sealed battery or mutilate the battery case. If
battery acid splashes in the eyes or on the skin, immediately
flush the affected area for 15 minutes with large quantities of
clean water. Seek immediate medical aid in the case of eye
contact. Never add acid to a battery after placing the battery in
service, as this may result in hazardous spattering of battery
acid.
Battery gases. Explosion can cause severe injury or
death. Battery gases can cause an explosion. Do not smoke
or permit flames or sparks to occur near a battery at any time,
particularly when it is charging. Do not dispose of a battery in a
fire.
To prevent burns and sparks that could cause an
explosion, avoid touching the battery terminals with tools or
other metal objects. Remove all jewelry before servicing the
equipment. Discharge static electricity from your body before
touching batteries by first touching a grounded metal surface
away from the battery. To avoid sparks, do not disturb the
battery charger connections while the battery is charging.
Always turn the battery charger off before disconnecting the
battery connections. Ventilate the compartments containing
batteries to prevent accumulation of explosive gases.
1. Disconnect wiring harness plug from connector on
voltage regulator. See Figure 7-1. Also disconnect
plug P7.
7-2 Component Testing and Adjustment
goggles
and
PowerBoostä III E
Single-Phase Generator
LED 1
LED 3
PowerBoostä V
Three-Phase Generator
1. Connector
Figure 7-1. Voltage Regulator
2. Connect an ammeter and a DC power supply
12-volt automotive battery to the positive (+) and
negative (-) brushes or exciter leads. Include a
10-amp fuse to protect the circuit in case of a
shorted rotor. Refer to Figure 7-2. Note and record
the ammeter reading.
1
1-850
1
LED 2
8
7
6
5
4
3
2
1
1-850
TP-5606 6/02