Alde Heating System - Nucamp T@B 320 Manual

Table of Contents

Advertisement

the car. Running on DC will run down the battery
quickly.
Dry Camping
While dry camping, instead of using DC mode, you
can also use the refrigerator as a cooler. Using ice
or frozen cold packs.
Purging Air from The Lines
If the refrigerator has not been used for a long
period or if the propane tanks have just been
refilled, air may be trapped in the supply lines.
Purge the air from the lines by pressing the
ON/OFF button to OFF and then back to ON 3-4
times. If repeated attempts fail to start the propane
operation, check to make sure the propane tanks are
not empty and that all manual shutoff valves in the
lines are open. When refueling, or parked near
gasoline pumps, shut off all propane appliances.
Failure to heed this warning could cause a fire or
explosion, resulting in death or severe personal
injury as well as damage to the camper and/or
surrounding area.
NOTE: Keep the vent underneath the refrigerator
unobstructed.

Alde Heating System

Operating the Alde Heater
The Alde heater comes
with its own owner's
manual. Please read its
instructions on how to
operate the heater.
Please NOTE: If you have properly drained the
Alde heater from any RV winterizing fluids you are
safe use the Alde heater for winter camping while
the system has been winterized and you will not
damage the Alde heater or any of its components.
The proper winterization for the Alde heater so that
is it safe to use is "if you did not use RV anti-freeze
to winterize the camper but instead used air to blow
out the system", then there is nothing you need to
do to use the Alde heater for heat. If you did use RV
anti-freeze to winterize you will need to open the
Alde relieve valve to drain the anti-freeze out from
the tank.
Alde Controllers
The Alde system will be operated either by a Digital
Touch Screen Panel or a 214 Manual Controller. If
you have the digital touch screen panel you can find
the operating instructions on page 9 to 15 in the
Alde Operator's Manual that comes with the Alde
system.
Digital Control
To light the Alde system on
propane, press the Propane icon
"On", on the thermostat. The On
icon is activated and changes
color to green. As seen in the
photo.
To switch off gas operation,
press "Off" icon.
If the gas failure code appears, make sure the gas is
connected and turned on. If this is the first time you
are lighting the Alde since connecting the propane
tank, then the gas might not be at the Alde system
yet as it takes a few minutes for it to flow through
the regulator and to the appliances. If the gas failure
code does appear, turn off the Alde for a few
seconds then turn it back on.
Manual Control
If you have the
manual control
thermostat, the boiler
is controlled by the
slider switches on the
control panel. The desired temperature in the trailer
is set and controlled by the control panel's
thermostat.
Functions on the control panel:
a) Electrical cartridge OFF.
b) Electrical cartridge ON at 1050 Watts
power.
c) Electrical cartridge ON at 2100 Watts
power.
d) Electrical cartridge ON at 3150 Watts power
(If the boiler is equipped with this power
level).
e) LP gas burner OFF.
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents