Pressure Limit Control (Pn 58409) - Regulator Removal And Installation - Condec UVC1000 Operation And Maintenance Manual

Table top & rack-mountable pneumatic vacuum generator / pressure controller
Table of Contents

Advertisement

UVC1000 Cover Installation:
1. Vent input line pressure.
2. Pull out the PRESSURE LIMIT CONTROL knob, until you hear a click. Close regulator, rotate knob
counter-clockwise, until it stops. Push knob inward.
3. Replace and align cover.
4. Install and tighten the six screws (PN 14839) that secure the cover to the enclosure.
5. Replace input hose, if not previously attached.
UVC1010 Cover Removal:
1. Vent input line pressure and remove input and port hoses.
2. Pull out the PRESSURE LIMIT CONTROL knob, until you hear a click. To close regulator, rotate knob
counter-clockwise, until it stops. Push knob inward.
3. Loosen and remove the two screws (PN 14839) on front of panel (1) and on rear of unit (1). These secure
the cover to the enclosure.
4. Lift and remove the cover.
UVC1010 Cover Installation:
1. Vent input line pressure.
2. Pull out the PRESSURE LIMIT CONTROL knob, until you hear a click. Close regulator, rotate knob
counter-clockwise, until it stops. Push knob inward.
3. Replace and align cover.
4. Install and tighten the two screws (PN 14839) that secure the cover to the enclosure.
5. Replace input hose, if not previously attached.
3.2.3

Pressure Limit Control (PN 58409) - Regulator Removal and Installation

Tools required:
7/16" open end wrench
hex wrench (.186")
channel locks
A/R 1/4" wide Teflon tape, (PN 60575)
Removal:
1. Remove cover from its enclosure as described in Section 3.2.2 on page 4, and place on a bench top.
2. Note the orientation and remove the tubing sections that connect to the regulator inlet and outlet fittings.
3. Loosen and remove regulator mounting nut from the front of panel, by using channel locks.
NOTE:
Be careful not to scratch front of panel.
4. Note the orientation, then remove the regulator by sliding out from the panel rear.
5. Note the orientation of the inlet and outlet fittings in the regulator. Remove the fittings and any remnants
of Teflon tape from the pipe threads.
Installation:
1. Wrap two layers of Teflon tape on the pipe threads of each fitting and install into the inlet and outlet of
the regulator and ensure that each is oriented properly.
2. Insert the new regulator into the panel through rear of panel and rotate to proper position. Thread and
tighten the mounting nut onto the regulator body from the panel front.
3. Attach the tubing sections to the inlet and outlet fittings.
4. Test UVC1000/UVC1010 as described in Section 3.2.1 on page 4.
Maintenance
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uvc1010

Table of Contents