Installation and operating instruction
Read carefully before installation, commissioning and operation

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Eco Logic and is the answer not in the manual?

Questions and answers

Summary of Contents for BADU Eco Logic

  • Page 1 Poolregelung BADU Eco Logic ® Installation and operating instruction Read carefully before installation, commissioning and operation...
  • Page 2: Table Of Contents

    Malfunctions with error messages 2.3. Z.2. Replacing the fuse 2.4. Graphic overview Z.3. Maintenance 2.5. Message log 2.6. Reset/clear Connection example for BADU Eco pumps 28 Display mode 3.1. Schematic 3.2. Overview 3.3. Alternating 3.4. Sleep mode Operating mode 4.1.
  • Page 3: Ec Declaration Of Conformity

    Safety instructions A.1. EC declaration of conformity By affi xing the CE mark to the unit the manufacturer declares that the BADU®Eco Logic conforms to the following relevant safety regulations: EC low voltage directive 2006/95/EC EC electromagnetic compatibility directive 2004/108/EC. Conformity has been verifi ed and the corresponding documentation and the EC declaration of conformity are kept on fi le by the manufacturer. A.2. General instructions These installation and operating instructions contain basic instructions and important information regarding safety, installation, commissioning, maintenance and the optimal use of the unit.
  • Page 4: Changes To The Unit

    Safety instructions A.4. Changes to the unit Changes to the unit can compromise the safety and function of the unit or the entire system. • Changes, additions to or conversion of the unit are not permitted without written authorisation from the manufacturer • It is likewise forbidden to install additional components that have not been tested together with the unit • If it becomes clear that safe operation of the unit is no longer possible, for example because of damage to the housing, turn the controller off immediately • Any parts of the unit or accessories that are not in perfect condition must be replaced immediately • Use only original spare parts and accessories from the manufacturer • Markings made on the unit at the factory must not be altered, removed or made illegible...
  • Page 5: Description Of Controller

    Description of controller B.1. Specifications Electrical specifications: Mains voltage 230 VAC +/-10 % Mains frequency 50 - 60 Hz Power consumption 1,5 W - 2,3 W Internal fuse 4A slow blow 250 V Protection category IP40/IP 44 (only with the supplied gasket set) Protection class Overvoltage category Degree of pollution category...
  • Page 6: About The Controller

    Description of controller B.3. About the controller The BADU®Eco Logic pool controller facilitates effi cient use and function control of your solar or heating system with your swimming pool. The device is impressive most of all for its functionality and simple, almost self-explanatory operation. For each step in the input process the individual entry keys are assigned to appropriate functions and explained. The controller menu contains headwords for the measured values and settings as well as help texts or clearly-structured graphics. The BADU®Eco Logic can be used as a simple system illustrated and explained under “B.6. Hydraulic variants” on page 7.
  • Page 7: Hydraulic Variants

    Description of controller B.6. Hydraulic variants The following illustration should be viewed only as schematic diagrams showing the respective hydraulic system and do not claim to be complete. The controller does not replace safety devices under any circumstances. Depending on the specifi c application, additional system components and safety components may be required, such as check valves, non-return valves, safety temperature limiters, scalding protectors etc.
  • Page 8: Installation

    Installation C.1. Wall installation Install the controller in dry areas only and under the ambient conditions descri- bed under “B.1. Specifi cations”. Follow the instructions below: 1. Unscrew cover completely C.1.1. 2. Carefully pull upper part of housing from lower part. Terminal clamps are released during this process. 3. Set upper part of housing aside, being sure not to touch the electric when doing 4.
  • Page 9: Electrical Connection

    Installation C.2. Electrical connection Before working on the unit, switch off the power supply and secure it from being switched on again! Check for the absence of power! Electrical connections may only be made by a specialist and in compli- ance with the applicable regulations. Do not use the controller if the housing shows visible damage, for ex- ample cracks. Low-voltage cables such as sensor cables must be routed separately from the mains voltage cables. Feed sensor cables into the left-hand side of the unit only and mains voltage cables into the right-hand side only.
  • Page 10 Installation 1. Open controller casing (“C.1. Wall ins- C.2.1. tallation” on page 8). 2. Strip cables by max. 55 mm, insert it, fi t the strain relief devices, strip the last 8-9 mm of the wires (Fig. C.2.1.). 3. Open the terminals using a suitable screwdriver (Fig. C.2.1.) and make electrical connections on the control- ler.
  • Page 11: Klemmplan Für Elektrischen Anschluss

    Installation Klemmplan für elektrischen Anschluss Low voltage Relais Mains CAN CAN max. 12 V Netzseite 230 VAC Low voltage max. 12 VAC/DC Mains voltage 230 VAC 50 - 60 Hz Terminal Connection for Terminal: Connection for: S1 (2x) without function Mains neutral conductor N S2 (2x) without function / Option: Mains phase conductor L Temp.-sensor only display...
  • Page 12: Operation

    Operation E.1. Display and input The display (1), with its extensive text and graphics mode, is almost self-explanatory, allowing easy operation of the controller. Inputs are made with 4 buttons (3+4), which have different functions depending on the context. The “esc” key (3) is always used to cancel or exit a menu. If applicable there will be a request for con- firmation as to whether the changes which have been made should be saved. The function of each of the other three keys Examples of display symbols: (4) is shown in the display line directly above...
  • Page 13: Commissioning Help

    Commission E.2. Commissioning help The fi rst time the controller is turned on and after the language and time are set, a query appears as to whether you want to param-etrise the controller using the commissioning help or not. The commis- sioning help can also be terminated or called up again at any time in the special functions menu.
  • Page 14: Menu Sequence And Menu Structure

    Operation E.4. Menu sequence and menu structure The graphics or overview mode appears when no key has been pressed for 2 mi- nutes or when the main menu is exited by pressing the “esc” key. Pressing a key in the graphics or overview mode will lead directly to the main menu. Here the following menues are available: Function control of the system with opera- 2.
  • Page 15: Statistics

    Statistics Statistics The menu “2. Statistics” is used for function control and long-term monitoring of the system. The menu is closed by pressing the “esc” key or selecting “Exit statistics”. For analysis of the system data it is essential for the time to be set ac- curately on the controller. Please note that the clock only has a battery reserve for 24 hours and must therefore be reset afterwards.
  • Page 16: Display Mode

    Display mode Display mode The menu “3. Display mode” is used to defi ne the controller’s display for normal operation. This display appears whenever two min utes go by without any key being pressed. The main menu appears again when a key is pressed. The menu is closed by pressing the “esc” key or selecting “Exit display mode”. 3.1. Schematic In graphics mode, the selected hydraulic systems are depicted with operating states of the connected consumers.
  • Page 17: Operating Mode

    Operating mode Operating mode In the menu “4. Operating mode” the con- troller can either be placed in automatic mode, switched off or placed in a manual operating mode. The menu is closed by pressing the “esc” key or selecting “Exit operating mode”. 4.1. Automatic Automatic mode is the normal operating mode of the controller. Only automatic mode provides proper controller function taking into account the parameters that have been set! After an interruption of the mains voltage the controller automatically returns to the last operating mode selected! 4.2.
  • Page 18: Settings

    The menu is closed by pressing the “esc” key or selecting “Exit settings”. 5.3. Filter pump Filter pump run time The BADU®Eco Logic controls the fi ltering time of the pump in which the fi lte- ring times for the minimum hourly and daily fi ltering are taken into consideration. 5.3.1. Min. hourly fi ltering time This menu is used to set the hourly fi ltering time. The pump is switched on at the end of the hour for the set time.
  • Page 19: Clear Rinse Level V1

    Settings 5.3.6. Clear rinse level V1 Level for a variable speed pump connection at V1. Setting range: 1 - 100 %/Default: 50 % 5.3.7. -- 5.3.8. D aily filtering time This menu is used to set the min. daily filtering time. This ensures that the filter unit runs each day for the time set here. Up to three filtering times can be set each day and copied to another day. Eco mode: if the solar unit or the auxiliary heating runs (the filter then also runs), these operating hours will be subtracted from the filtering times set here. Setting range: off, daily 0:00 - 23:59/Default: daily 16:00 - 21:00 5.4. Relay 1 5.4.1. Function The function for relay 1 is set here.
  • Page 20: Protective Functions

    Protections Protective functions The menu “6. Protections/Protective functions” can be used to activate and set various protec- tive functions. This does not under any circum- stances replace the safety facilities to be provided by the customer! The menu is closed by pressing the “esc” key or selecting “Exit protective functions”. 6.1. Seizing protection If the seizing protection is activated, the controller switches the relay in question and the con- nected consumer on every day at 12:00 (setting “daily”) or weekly on Sundays at 12:00 (setting “weekly”) for 5 seconds in order to prevent the pump and/or the ball valve or other consumer from sticking after an extended stationary period.
  • Page 21: Special Functions

    Special functions Special functions The menu “7. Special functions” is used to set basic items and expand functions. Other than the time, all settings may only be made by a specialist. The menu is closed by pressing the “esc” key or selecting “Exit special functions”. 7.1. -- 7.2. Time and date This menu is used to set the current time and date. For analysis of the system data it is essential that the time is set accu- rately on the controller.
  • Page 22: Daylight Saving Time

    Special functions 7.7. -- 7.8. Daylight saving time When this function is active, the controller’s clock changes automatically to and from DST (Daylight Saving Time). Default: yes Setting: yes, no/Default: yes 7.9. Signal mode Settings for the filter level switching mode. Impulse: short signal impulses when switching the pump levels. Permanent: the switching signal for the pump level is permanently on for the switched level during the pump filtering time.
  • Page 23: Menu Lock

    Menu lock Menu lock The menu “8. Menu lock” can be used to secure the controller from unintentional changing of the set values. The menu is closed by pressing the “esc” key or selecting “Exit menu lock”. The menus listed below remain completely accessible despite the menu lock being activated and can be used to make adjustments if necessary: Analysis Display mode 7.2.
  • Page 24: Service Data

    Service data Service data The menu “9. Service values” can be used for remote diagnosis by a specialist or the manufacturer in the event of an error. Enter the values at the time when the error occurs e.g. in the table. The menu can be closed at any time by pressing the “esc” key.
  • Page 25: Malfunctions With Error Messages

    Malfunctions Z.1. Malfunctions with error messages If the controller detects a malfunction, the red light fl ashes and the warning symbol also appears in the display. If the error (LED fl ashes + is no longer present, the warning symbol warning symbol) changes to an info symbol and the red light no longer fl...
  • Page 26: Replacing The Fuse

    Malfunctions Z.2. Replacing the fuse Repairs and maintenance may only be performed by a specialist. Before working on the unit, switch off the power supply and secure it from being switched on again! Check for the absence of power! Only use the spare fuse supplied or a fuse of the same design with the following specifi cations: T 4 A/250 V If the mains voltage is switched on and Z.2.1.
  • Page 27 Notes The service values (see “2. Statistics” on page 16) include not only current measurement values and operating states, but also all of the set- tings for the controller. Write the service values down once after com- missioning has been successfully completed. In the event of uncertainty as to the control response or malfunctions the service values are a proven and successful method for remote diagnosis.
  • Page 30 Commissioner‘s notes:...
  • Page 31 Hydraulic variant set: Commissioned on: Commissioned by: Final declaration: Although these instructions have been created with the greatest possi- ble care, the possibility of incorrect or incomplete information cannot be excluded. Subject as a basic principle to errors and technical changes.
  • Page 32 Here you will find further FAQs and notes regarding the BADU Eco Logic:...
  • Page 33 BADU Eco Logic - capacitor/GoldCap Within a few minutes the charging capacitor for the control is activated and retains the date and time for min. 24 hours. There are no guarantees that the date and time will be retained for disruptions exceeding this time frame. However it is possible.
  • Page 34 Switch installation It may be necessary to use a switch for the customer for the stop contact S4. A hole can be drilled into the low voltage side to insert the switch (IPx4) in order to avoid installing an extra housing. 10,6mm A d=6mm drill should be used.
  • Page 35 BADU Logic 1 BADU Logic 2 BADU Logic 3 BADU Eco Logic folgenden einschlägigen Bestimmungen entspricht: correspond aux dispositions pertinentes suivantes: / complies with the following provisions applying to it: / è conforme alle sequenti disposizioni pertinenti: / in de door ons geleverde uitvoering voldoet aan de eisen van de in het vervolg genoemde bepalingen: / cumple las siguientes disposiciones pertinentes: / vastaa seuraavia asiaan kuuluvia määräyksiä: / odpowiada następującym odnośnym normom: / je v souladu s požadavky směrnic, které...