6. Connect the device to the local network, refer to the section "Ethernet port (Page 45)".
7. Connect the terminal with as short a cable as possible ≤ 150 mm and a large cross-
sectional area of 1.5 mm² to the functional ground of the system, see section "Terminals
(Page 18)" and section "Grounding (Page 41)".
Dismantling
1. Disconnect all connected cables.
2. Loosen the attachment of the mounting frame.
3. Using a screwdriver, pull down the catch on the rear of the device.
4. Push the device out of the mounting frame.
SCALANCE S615
Operating Instructions, 08/2018, C79000-G8976-C389-04
3.7 Installation in a 19" mounting frame
Installation
33