Technical specifications

Article number
Ethernet interface
Attachment to Industrial
Ethernet
Electrical data
Power supply
Digital input
Digital output
Permitted ambient conditions
Ambient temperature
SCALANCE S615
Operating Instructions, 08/2018, C79000-G8976-C389-04
SCALANCE S615
6GK5 615-0AA00-2AA2
Quantity
5
Design
RJ-45 jack
Characteristics:
Input voltage
12 to 24 VDC
min. 10.8 VDC, max. 28.8 V
Maximum power con-
3 W
sumption
Quantity
1
Design
Terminal block, 2 terminals
Characteristics:
Rated voltage 24 VDC Safe Extra Low Voltage
(SELV)
For state "1": 13 to 30 VDC
For state "0": -30 to 3 VDC
Maximum input current 8 mA
Cables should be routed in pairs
Maximum cable length < 30 m
Inputs isolated from electronics.
Quantity
1
Design
Terminal block, 2 terminals
Properties
Rated voltage 24 VDC Safe Extra Low Voltage
(SELV)
internally not current limited
Maximum current carrying capacity 1 A
Cables should be routed in pairs
Maximum cable length < 30 m
Output isolated from electronics
During operation
-40 °C ... +70 °C (vertical installation)
Installed horizontally, the device can be used for
ambient temperatures up to 40 °C.
During storage
-40 ℃ to +80 ℃
During transportation
-40 ℃ to +80 ℃
10/100BASE-T
Ethernet IEEE 802
10/100 Mbps