Flame DUALKEY EURO MODUL Manual

Advertisement

Quick Links

FLAME
DUALKEY EURO MODUL
MANUAL
Version 1.00

Advertisement

Table of Contents
loading

Summary of Contents for Flame DUALKEY EURO MODUL

  • Page 1 FLAME DUALKEY EURO MODUL MANUAL Version 1.00...
  • Page 2: Table Of Contents

    Manual FLAME DUALKEY MODULE Version 1.00 Contents 1. Short description ............... 3 2. Hardware / Connection .............. 3 2.1 Module overview 2.2 Connection 3. Play Modi ................... 5 3.1 Mode ONE SHOT 3.2 Mode GATE 3.3 Mode LOOP 4. Parameter .................. 6 4.1 SHAPE (shape of envelope)
  • Page 3: Short Description

    1. Short description Dualkey is composed of two modulators with A(H)D, A(S)R and Loop modes. Length and shape of rising / falling edge can be adjusted manually as well as influenced by CV signals. At most, the module emits voltages of 0..+10v. Additionally the circuits generate a trigger signal after each envelope cycle.
  • Page 4: Connection

    2.2. Connection to the modular system (Doepfer Bus) The module is delivered with a connected ribbon cable for the Doepfer bus. The red lead marks -12 volt. Connecting the module please note the right polarity! If the module is poled accidentally wrong safety diodes avoid the immediate destruction of the module but further damages cannot be excepted.
  • Page 5: Play Modi

    3. PLAY MODI 3.1. Mode ONE SHOT Keypress (or Trigger via KEY input) starts the envelope (voltage via CV output jack). The enve- lope plays only one-time and create after the end a short trigger impuls via the END output jack. Reset the envelope, if you press again the key and while still play the envelope (Retrigger).
  • Page 6: Mode Loop

    3.3. Mode LOOP Play the evelopes in loop while hold down the key (or high level via KEY input). Each envelope create after the end a short trigger impuls via the END output jack. Set the lenght of the enve- lopes with POT TIME, set the shape with POT SHAPE and set the output level with POT LEVEL.
  • Page 7: Time (Duration Of Envelope)

    4.2. TIME (duration of envelope) POT TIME set the duration of the envelope. There are three ranges between 1ms..1min, selec- table with the TIME range switch . If you use the TIME CV input, then the POT is an attenuator of the CV input.
  • Page 8 - electric damage caused by improper connecting (wrong power supply/ jacks/ MIDI connections/ voltage problems). If you have any complaints please contact your dealer or send an e-mail to: service@flame.fortschritt-musik.de 5.3 Terms of production conformity: CE, RoHS, UL 5.4 Disposal The device is produced with RoHS-conformity (subject to the regulations of the European Union) and is free of hazardous substances (like mercury, plumb, cadmium and hexavalent chrome).

Table of Contents