Summary of Contents for Levitronix LEVIFLOW LFIF Series
Page 1
If the flowmeters have to be configured for other parameter settings then the LEVIFLOW Configuration Software (see relevant manual Levitronix Doc.# PL-4501-00) is necessary. Please familiarize yourself with the contents of this manual to ensure the safe and effective use of this product. After reading, please store the manual where the personnel responsible for operating can readily refer to it at any time.
® User Manual for LEVIFLOW LFIF-06 Flowmeters www.levitronix.com Table of Contents SAFETY PRECAUTIONS ............................3 SPECIFICATIONS ..............................4 Component Overview ............................4 General Specifications ............................4 Basic Dimensions of Main Components ......................5 2.3.1 Dimensions of Flowmeter ..............................5 2.3.2 Dimensions of Cables ..............................
1 Safety Precautions CAUTION Do not under any circumstances open the flowmeter housing. Levitronix does not assume responsibility for any damage, which occurs under such circumstances. WARNING Hazardous voltage may be present. In case of the usage of an inadequate AC/DC power supply, mains voltages may be present (even if the system is designed for 24VDC).
® User Manual for LEVIFLOW LFIF-06 Flowmeters www.levitronix.com 2 Specifications 2.1 Component Overview ® Figure 1: Standard LEVIFLOW LFIF components and accessories Pos. Article Name Part # Feature/Description Note LFIF-06 100-30393 Integrated Flowmeter Calibration parameters are stored in flowmeter. Waterproof lock-release mounting connector type for flowmeter connection.
® User Manual for LEVIFLOW LFIF-06 Flowmeters www.levitronix.com 2.3 Basic Dimensions of Main Components 2.3.1 Dimensions of Flowmeter Figure 2: Dimensions of LFIF-06 Flowmeter 2.3.2 Dimensions of Cables Figure 3: Dimensions of extension cable LFE-E.1/2/3-50 Note: Maximum bending load is 15N.
® manual is dealing with the standard configuration. For setting up other configurations the LEVIFLOW Configuration Software is needed. Consult the “Configuration-SW User Manual” (Levitronix Doc.# PL-4501- 00) for more detailed description. Note: The LFIF-06 flowmeter needs configuration software version V1.34 or higher.
® User Manual for LEVIFLOW LFIF-06 Flowmeters www.levitronix.com 3 Installation 3.1 Electrical Installation 3.1.1 Overview and Preparation 4: „High“ LED 3: „Flow“ LED 5: „Low“ LED 2: „Zero“ Button 1: Cable Connector 6: „Arrow“ Label for Flow Direction 8: Type Label...
® User Manual for LEVIFLOW LFIF-06 Flowmeters www.levitronix.com Cable Wires Cable Wires Example of User LFIF-06 Example of User LFIF-06 Colors/Designation Colors/Designation Interface Circuit Interface Circuit LFE-E.1 LFE-E.3 Relais Relais Max. 30V / 10mA Blue: Digital Output Max. 30V / 10mA...
(the K-Factor and the 5 Calibration Values) is also part of the package. In case this data should have to be changed to the users specific needs LEVIFLOW ® Configuration Software can be used. Consult the configuration “Configuration-SW User Manual” (Levitronix Doc.# PL-4501-00) for ® handling with the LEVIFLOW configuration software.
Figure 5 shows the standard configuration of the digital and analogue output. For other configurations the ® LEVIFLOW configuration software has to be used (according manual is Levitronix Doc.# PL-4501-00). Note: The LFIF-06 flowmeter needs configuration software version V1.34 or higher. 4.2.2 Operation with RS485 Operation with communication over an RS485 bus is possible.
® For debugging, data collection and configuration of the flowmeter system the LEVIFLOW Configuration ® ® Software is available at Levitronix . Contact Levitronix for a sample of the configuration software and the according manual (Levitronix Doc.# PL-4501-00). An approved USB to RS485 adaptor with the according connection cable can be ordered according to the information in Table 1.
More detailed error analysis can be done with the LEVIFLOW Configuration Software. Contact Levitronix for a sample of the configuration software and the according manual (Levitronix Doc.# PL-4501-00). Note: The LFIF-06 flowmeter needs configuration software version V1.34 or higher.
® User Manual for LEVIFLOW LFIF-06 Flowmeters www.levitronix.com 8 Appendix 8.1 Regulatory Status 8.1.1 CE Marking ® The LEVIFLOW LFIF-06 flowmeter, in its various configurations is in conformity with the below mentioned European Directives. The flowmeter is thought to be used in hydraulic circuits of the production equipment of Semiconductor and Chemical industry.
Need help?
Do you have a question about the LEVIFLOW LFIF Series and is the answer not in the manual?
Questions and answers