A/D Converter Check - JPS PDA Series Instruction Manual

Table of Contents

Advertisement

Pr.64 Control Input Terminal status
Monitors the RUN & REV input terminal status.
Digit 1: RUN Input Terminal Status
Digit 0: REV Input Terminal Status
0 0
. .
Control Input Terminal status
Pr.65 Digital Output Terminal Status
Monitors the DO1, DO2 & RY (1,2) output terminal status.
Digit 2: DO1 Output Terminal Status
Digit 1: DO2 Output Terminal Status
Digit 0: RELAY Output Status
0
0 0 0
.
Digital Output Terminal Status

13.3 A/D Converter Check

Pr.55 A/D CHANNEL SELECT
Pr.56 A/D CONVERSION DATA
Use Pr.55 to select the desired channel for monitoring, then the 10-bits A/D converter of CPU will execute Analog to
Digital conversion and put the conversion result in Pr.56.
The range of the converted data is from 0 to 1023 corresponding to full range input.
Pr.55
Pr.56 (A/D DATA)
0
VDC channel A/D value
1
Iv channel A/D value
Note: For PDAN series only.
2
Iw channel A/D value
Note: For PDAN series only.
3
AI1 channel A/D value
4
AI2 channel A/D value
5
AI3 channel A/D value
6
Thermistor A/D value
7
Reserve
8
Shows QUEUE content while using RS-485 communication
port to write parameter
Note: For PDAN series only.
9-31
Reserve
32
Shows COUNTER value when it is used.
Note: For PDAN series only.
0 0
. .
RUN
REV
DI3
. . .
DO1
DO2 RELAY
50

Hide quick links:

Advertisement

Table of Contents
loading