Fujitsu GENERAL ARXH12-18KMTAP Design & Technical Manual
Fujitsu GENERAL ARXH12-18KMTAP Design & Technical Manual

Fujitsu GENERAL ARXH12-18KMTAP Design & Technical Manual

3-unit multi-split type, indoor/outdoor
Hide thumbs Also See for GENERAL ARXH12-18KMTAP:
Table of Contents

Advertisement

Quick Links

AIR CONDITIONER
3-unit multi-split type
DESIGN & TECHNICAL MANUAL
INDOOR
ASHG07–14KMTB
ASHH07–14KMCG-B
ASHG07–14KMCC
ASHH07–14KMCH-B
ASHG07–14KMCE
ASHG07–14KMCF
ASHH07–14KMCG
ASHH07–14KMCH
ASHG18KMTB
ASHG18KMTE
AUXG07–18KVLA
ARXG07–14KSLAP
ASHG07–14KETA
ASHG07–14KETA-B
ASHG07–14KETE-B
ASHG07–14KETF-B
ABHG18KRTA
AGHG09–14KVCA
ARXG07–14KLLAP
ARXG18KSLAP
ARXG18KLLAP
ASHG07–14KGTB
ASHG07–14KETE
ASHG07–14KGTE
ASHG07–14KETF
ASHG07–14KGTF
ASHH07–14KGTG
ASHH07–14KGTH
OUTDOOR
ARXH12–18KMTAP
ASHH05–12KNCA
ASHH05–12KNCH
AOHG18KBTA3
AOHG24KBTA3
DR_MU024EG_12
2024.12.16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GENERAL ARXH12-18KMTAP and is the answer not in the manual?

Questions and answers

Summary of Contents for Fujitsu GENERAL ARXH12-18KMTAP

  • Page 1 AIR CONDITIONER 3-unit multi-split type DESIGN & TECHNICAL MANUAL INDOOR AUXG07–18KVLA ARXG07–14KSLAP ARXG07–14KLLAP ARXH12–18KMTAP ARXG18KSLAP ARXG18KLLAP ASHG07–14KMTB ASHH07–14KMCG-B ASHG07–14KETA ASHG07–14KGTB ASHH05–12KNCA ASHG07–14KMCC ASHH07–14KMCH-B ASHG07–14KETE ASHG07–14KGTE ASHH05–12KNCH ASHG07–14KMCE ASHG07–14KETF ASHG07–14KGTF ASHG07–14KMCF ASHG07–14KETA-B ASHH07–14KGTG ASHH07–14KMCG ASHG07–14KETE-B ASHH07–14KGTH ASHH07–14KMCH ASHG07–14KETF-B OUTDOOR ASHG18KMTB ABHG18KRTA AGHG09–14KVCA AOHG18KBTA3 ASHG18KMTE...
  • Page 2 • For further details, please check with our authorized dealer. Trademarks ™ FGLair is trademark of FUJITSU GENERAL LIMITED in the United States, other countries or both. “AIRSTAGE Mobile” is a trademark of FUJITSU GENERAL LIMITED. Android and Google Play are trademarks of Google LLC.
  • Page 3: Table Of Contents

    CONTENTS Part 1. INDOOR UNIT................1 1. Model lineup ....................2 1-1. Connectable indoor units to each outdoor unit..............5 1-2. Indoor unit connection patterns..................6 2. Specifications....................9 2-1. Compact cassette type ....................9 2-2. Mini duct type.........................11 2-3. Slim duct type ........................13 2-4. Medium static pressure duct type ..................15 2-5.
  • Page 4 CONTENTS (continued) 8. Airflow ......................152 8-1. Compact cassette type ....................152 8-2. Mini duct type.......................153 8-3. Slim duct type ......................154 8-4. Medium static pressure duct type ................155 8-5. Wall mounted type .......................156 8-6. Ceiling type ........................167 8-7. Floor type ........................168 9. Noise level curve..................169 9-1.
  • Page 5 CONTENTS (continued) 14-14.Simple remote controller (UTY-RSNGM: Optional part)..........309 14-15.Simple remote controller (UTY-RSRG and UTY-RHRG: Optional parts) ....313 15. Function settings ..................317 15-1.Compact cassette, Mini duct, Slim duct types indoor unit (setting by DIP switch)..317 15-2.Medium static pressure duct type ................319 15-3.Indoor unit (setting by wireless remote controller)............320 15-4.Indoor unit (setting by wired remote controller) ............340 15-5.Indoor unit (setting by simple remote controller) ............353...
  • Page 6 CONTENTS (continued) Part 2. OUTDOOR UNIT (3 UNITS TYPE) ........415 1. Specifications....................416 2. Dimensions....................418 2-1. Models: AOHG18KBTA3 and AOHG24KBTA3............418 3. Installation space ..................419 3-1. Models: AOHG18KBTA3 and AOHG24KBTA3............419 4. Refrigerant circuit ..................422 4-1. Models: AOHG18KBTA3 and AOHG24KBTA3............422 5. Wiring diagram ..................423 5-1.
  • Page 7 CONTENTS (continued) 16. Outdoor unit installation precautions .............564 16-1.Places where prohibited for use..................564 16-2.Points to remember when installing ................564...
  • Page 9: Part 1. Indoor Unit

    Part 1. INDOOR UNIT COMPACT CASSETTE MINI DUCT TYPE: TYPE: AUXG07–18KVLA ARXG07–14KSLAP ARXG18KSLAP SLIM DUCT TYPE: MEDIUM STATIC PRES- SURE DUCT TYPE: ARXG07–14KLLAP ARXG18KLLAP ARXH12–18KMTAP WALL MOUNTED TYPE: ASHG07–14KGTB ASHG07–14KGTE ASHG18KMTB ASHG07–14KGTF ASHG18KMTE ASHH07–14KGTG ASHH07–14KGTH ASHG07–14KMTB ASHG07–14KETA ASHH05–12KNCA ASHG07–14KMCC ASHG07–14KETE ASHH05–12KNCH ASHG07–14KMCE ASHG07–14KETF...
  • Page 10: Model Lineup

    1. Model lineup Indoor unit (other than wall-mounted type) AUXG07KVLA ARXG07KSLAP ARXG07KLLAP ARXH12KMTAP AUXG09KVLA ARXG09KSLAP ARXG09KLLAP ARXH14KMTAP AUXG12KVLA ARXG12KSLAP ARXG12KLLAP ARXH18KMTAP AUXG14KVLA ARXG14KSLAP ARXG14KLLAP AUXG18KVLA ARXG18KSLAP ARXG18KLLAP ABHG18KRTA AGHG09KVCA AGHG12KVCA AGHG14KVCA - 2 - 1. Model lineup...
  • Page 11 Indoor unit (wall-mounted type) ASHG07KMTB ASHH07KMCG-B ASHG07KETA ASHG07KETA-B ASHG09KMTB ASHH09KMCG-B ASHG09KETA ASHG09KETA-B ASHG12KMTB ASHH12KMCG-B ASHG12KETA ASHG12KETA-B ASHG14KMTB ASHH14KMCG-B ASHG14KETA ASHG14KETA-B ASHG07KMCC ASHH07KMCH-B ASHG07KETE ASHG07KETE-B ASHG09KMCC ASHH09KMCH-B ASHG09KETE ASHG09KETE-B ASHG12KMCC ASHH12KMCH-B ASHG12KETE ASHG12KETE-B ASHG14KMCC ASHH14KMCH-B ASHG14KETE ASHG14KETE-B ASHG07KMCE ASHG07KETF ASHG07KETF-B ASHG09KMCE ASHG09KETF ASHG09KETF-B ASHG12KMCE...
  • Page 12 Outdoor unit AOHG18KBTA3 AOHG24KBTA3 - 4 - 1. Model lineup...
  • Page 13: Connectable Indoor Units To Each Outdoor Unit

    1-1. Connectable indoor units to each outdoor unit ●: Connectable / -: Not connectable Compact cassette Mini duct Outdoor unit ARXG07–14KSLAP AUXG07–18KVLA ARXG18KSLAP Btu class kW class AOHG18KBTA3 ● ● ● ● — ● ● ● ● — AOHG24KBTA3 ● ●...
  • Page 14: Indoor Unit Connection Patterns

    1-2. Indoor unit connection patterns ¢ 3-unit multi-split type AOHG18KBTA3 Combination no. Unit 1 Unit 2 Unit 3 Total — — — — — — — — — — — — — Numbers in column Unit 1, 2, 3, and Total indicate the indoor unit capacities as follows: 5: 5,000 Btu/h, 7: 7,000 Btu/h, 9: 9,000 Btu/h, 12: 12,000 Btu/h, 14: 14,000 Btu/h ..
  • Page 15 AOHG24KBTA3 Combination no. Unit 1 Unit 2 Unit 3 Total — — — — — — — — — — — — — — — — — — - 7 - 1-2. Indoor unit connection patterns 1. Model lineup...
  • Page 16 AOHG24KBTA3 Numbers in column Unit 1, 2, 3, and Total indicate the indoor unit capacities as follows: 5: 5,000 Btu/h, 7: 7,000 Btu/h, 9: 9,000 Btu/h, 12: 12,000 Btu/h, 14: 14,000 Btu/h ..- 8 - 1-2. Indoor unit connection patterns 1.
  • Page 17: Specifications

    2. Specifications 2-1. Compact cassette type Model name AUXG07KVLA AUXG09KVLA AUXG12KVLA AUXG14KVLA Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.15 0.19 0.22 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type ×...
  • Page 18 Model name AUXG18KVLA Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.30 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Turbo fan × 1 Motor output HIGH Cooling QUIET...
  • Page 19: Mini Duct Type

    2-2. Mini duct type Model name ARXG07KSLAP ARXG09KSLAP ARXG12KSLAP ARXG14KSLAP Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class HIGH Input power QUIET Running current 0.29 0.33 0.38 0.58 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET...
  • Page 20 Model name ARXG18KSLAP Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class HIGH Input power QUIET Running current 0.49 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Sirocco fan × 3 Motor output Recommended static pressure 0 to 50...
  • Page 21: Slim Duct Type

    2-3. Slim duct type Model name ARXG07KLLAP ARXG09KLLAP ARXG12KLLAP ARXG14KLLAP Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.33 0.30 0.35 0.51 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type ×...
  • Page 22 Model name ARXG18KLLAP Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.44 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Sirocco fan × 3 Motor output Recommended static pressure 0 to 90 HIGH...
  • Page 23: Medium Static Pressure Duct Type

    2-4. Medium static pressure duct type Model name ARXH12KMTAP ARXH14KMTAP ARXH18KMTAP Power supply 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.34 0.49 0.52 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type ×...
  • Page 24: Wall Mounted Type

    2-5. Wall mounted type Model name ASHG07KMTB ASHG09KMTB ASHG12KMTB ASHG14KMTB Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.24 0.30 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type ×...
  • Page 25 Model name ASHG07KMCC ASHG09KMCC ASHG12KMCC ASHG14KMCC Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.24 0.30 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Crossflow fan ×...
  • Page 26 Model name ASHG07KMCE ASHG09KMCE ASHG12KMCE ASHG14KMCE Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.24 0.30 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Crossflow fan ×...
  • Page 27 Model name ASHG07KMCF ASHG09KMCF ASHG12KMCF ASHG14KMCF Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.24 0.30 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Crossflow fan ×...
  • Page 28 ASHH07KMCG ASHH09KMCG ASHH12KMCG ASHH14KMCG Model name ASHH07KMCG-B ASHH09KMCG-B ASHH12KMCG-B ASHH14KMCG-B Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.30 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type ×...
  • Page 29 ASHH07KMCH ASHH09KMCH ASHH12KMCH ASHH14KMCH Model name ASHH07KMCH-B ASHH09KMCH-B ASHH12KMCH-B ASHH14KMCH-B Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.30 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type ×...
  • Page 30 ASHG07KETA ASHG09KETA ASHG12KETA ASHG14KETA Model name ASHG07KETA-B ASHG09KETA-B ASHG12KETA-B ASHG14KETA-B Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.24 0.30 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type ×...
  • Page 31 ASHG07KETE ASHG09KETE ASHG12KETE ASHG14KETE Model name ASHG07KETE-B ASHG09KETE-B ASHG12KETE-B ASHG14KETE-B Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.24 0.30 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type ×...
  • Page 32 ASHG07KETF ASHG09KETF ASHG12KETF ASHG14KETF Model name ASHG07KETF-B ASHG09KETF-B ASHG12KETF-B ASHG14KETF-B Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.24 0.30 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type ×...
  • Page 33 Model name ASHG07KGTB ASHG09KGTB ASHG12KGTB ASHG14KGTB Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.24 0.29 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Crossflow fan ×...
  • Page 34 Model name ASHG07KGTE ASHG09KGTE ASHG12KGTE ASHG14KGTE Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.24 0.29 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Crossflow fan ×...
  • Page 35 Model name ASHG07KGTF ASHG09KGTF ASHG12KGTF ASHG14KGTF Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.24 0.29 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Crossflow fan ×...
  • Page 36 Model name ASHH07KGTG ASHH09KGTG ASHH12KGTG ASHH14KGTG Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.29 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Crossflow fan × 1 Motor output HIGH Cooling...
  • Page 37 Model name ASHH07KGTH ASHH09KGTH ASHH12KGTH ASHH14KGTH Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.20 0.24 0.29 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Crossflow fan × 1 Motor output HIGH Cooling...
  • Page 38 Model name ASHH05KNCA ASHH07KNCA ASHH09KNCA ASHH12KNCA Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.11 0.12 0.19 0.20 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Crossflow fan ×...
  • Page 39 Model name ASHH05KNCH ASHH07KNCH ASHH09KNCH ASHH12KNCH Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.11 0.12 0.19 0.20 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Crossflow fan ×...
  • Page 40 Model name ASHG18KMTB Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power 37.5 Running current 0.35 HIGH Cooling QUIET Airflow rate HIGH 1,020 Heating QUIET Type × Qty Crossflow fan × 1 Motor output HIGH Cooling...
  • Page 41 Model name ASHG18KMTE Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power 37.5 Running current 0.35 HIGH Cooling QUIET Airflow rate HIGH 1,020 Heating QUIET Type × Qty Crossflow fan × 1 Motor output HIGH Cooling...
  • Page 42: Ceiling Type

    2-6. Ceiling type Model name ABHG18KRTA Power supply 1Ø 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.21 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Sirocco fan × 2 Motor output HIGH Cooling...
  • Page 43: Floor Type

    2-7. Floor type Model name AGHG09KVCA AGHG12KVCA AGHG14KVCA Power supply 230 V~ 50 Hz Available voltage range 198—264 V Capacity kW class Input power Running current 0.15 0.18 0.20 HIGH Cooling QUIET Airflow rate HIGH Heating QUIET Type × Qty Crossflow fan ×...
  • Page 44: Wireless Lan Control (For Kmcf, Kmcg, Kmcg-B, Ketf, Ketf-B, Kgtf, Kgtg, And Knca)

    After installation of mobile app, user registration is required. For user registration and setup infor- mation, refer to Setting Manual attached with the product. For the latest version of the wireless LAN control manuals, refer to the following web site. https://www.fujitsu-general.com/global/support/ - 36 - 3-1. System requirement 3.
  • Page 45: Dimensions

    4. Dimensions 4-1. Compact cassette type ¢ Models: AUXG07–18KVLA Unit: mm Grid type grille Hanging bolt position IR receiver Drain hose View A Ceiling Control Box View B View C - 37 - 4-1. Compact cassette type 4. Dimensions...
  • Page 46: Installation Space Requirement

     Installation space requirement Provide enough clearance for product safety. Unit: mm Strong and durable ceiling or more 1,000 1,000 or more or more 1,800 or more Obstruction Floor Maximum height from floor to ceiling (Unit: mm) 07 and 09 models 12 or larger models Standard 2,700...
  • Page 47: Mini Duct Type

    4-2. Mini duct type ¢ Models: ARXG07–14KSLAP Unit: mm Rear view Drain port P 100 × 6 = 600 Side view (L) Top view Side view (R) Front view Bottom view - 39 - 4-2. Mini duct type 4. Dimensions...
  • Page 48 ¢ Model: ARXG18KSLAP Unit: mm Rear view Drain port P 100 × 8 = 800 Side view (L) Top view Side view (R) Front view Bottom view - 40 - 4-2. Mini duct type 4. Dimensions...
  • Page 49: Maintenance Space Requirement

     Installation space requirement Provide sufficient installation space for product safety. Unit: mm Strong and durable ceiling Indoor unit Left Right side side or more* or more *: 400 or more when drain from drain pipe • When intaking air from back: •...
  • Page 50: Slim Duct Type

    4-3. Slim duct type ¢ Models: ARXG07–14KLLAP Unit: mm Rear view (Drain hose) Drain port 100 x 6 = 600 Side view (R) Side view (L) Top view Front view Bottom view - 42 - 4-3. Slim duct type 4. Dimensions...
  • Page 51 ¢ Model: ARXG18KLLAP Unit: mm Rear view (Drain hose) Drain port 100 x 8 = 800 Top view Side view (L) Side view (R) Front view Bottom view - 43 - 4-3. Slim duct type 4. Dimensions...
  • Page 52  Installation space requirement Provide sufficient installation space for product safety. In ceiling-concealed installations: Unit: mm 300 or more Strong and durable ceiling 20 or more Indoor unit Left Right side side 20 or more Service access Ceiling or more or more Floor ...
  • Page 53: Medium Static Pressure Duct Type

    4-4. Medium static pressure duct type ¢ Models: ARXH12–18KMTAP Unit: mm Rear view P100 × 5 = 500 Hole: × Φ4 PCD*160 Φ125 Φ4.5 P100 × 5 = 500 *: PCD (Pitch Circle Diameter) Side view (L) Top view Side view (R) Front view - 45 - 4-4.
  • Page 54  Installation space requirement Provide enough clearance for product safety. NOTE: The detailed component shape depends on the model. Unit: mm 20 or more 300 or more 20 or more* Ceiling 2,500 or more (When no ceiling) Floor *: According to the distance between the ceiling and the unit, the construction plan of the mainte- nance access differs.
  • Page 55 Unit: mm • Distance between the ceiling and the unit is from 20 to 300: Choose one of these methods to set up the maintenance access. Pattern A Maintenance access Control box 100 to 200 Pattern B 1,300 or more Control box Bottom view - 47 -...
  • Page 56: Wall Mounted Type

    4-5. Wall mounted type ¢ Models: ASHG07–14KMTB and ASHG07–14KMCC Unit: mm Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 - 48 - 4-5. Wall mounted type 4. Dimensions...
  • Page 57  Installation space requirement Provide sufficient installation space for product safety. Unit: mm 70 or more 40 or more Wall hook bracket Outline of the indoor unit 107 or more 183 or more 1,500 or more A: Install so that the flare connection part is outdoors. - 49 - 4-5.
  • Page 58 ¢ Models: ASHG07–14KMCE, ASHG07–14KMCF, ASHH07– 14KMCG, ASHH07–14KMCG-B, and ASHH07–14KMCH-B Unit: mm Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 - 50 - 4-5. Wall mounted type 4. Dimensions...
  • Page 59  Installation space requirement Provide sufficient installation space for product safety. Unit: mm 40 or more 70 or more Wall hook bracket 107 or more 183 or more Outline of the indoor unit 1,500 or more A: Install so that the flare connection part is outdoors. - 51 - 4-5.
  • Page 60 ¢ Models: ASHH07–14KMCH Unit: mm Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 - 52 - 4-5. Wall mounted type 4. Dimensions...
  • Page 61  Installation space requirement Provide sufficient installation space for product safety. Unit: mm 40 or more 70 or more Wall hook bracket 107 or more 183 or more Outline of the indoor unit 1,500 or more A: Install so that the flare connection part is outdoors. - 53 - 4-5.
  • Page 62 ¢ Models: ASHG07–14KETA, ASHG07–14KETA-B, ASHG07– 14KETE, ASHG07–14KETE-B, ASHG07–14KETF, and ASHG07– 14KETF-B Unit: mm (950) Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 - 54 - 4-5. Wall mounted type 4. Dimensions...
  • Page 63  Installation space requirement Provide sufficient installation space for product safety. Unit: mm 40 or more 40 or more Wall hook bracket Outline of the indoor unit 166 or more 211 or more 1,500 or more The flare connection part should be installed outdoors.
  • Page 64 ¢ Models: ASHG07–14KGTB Unit: mm Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 - 56 - 4-5. Wall mounted type 4. Dimensions...
  • Page 65  Installation space requirement Provide sufficient installation space for product safety. Unit: mm 70 or more 40 or more Wall hook bracket Outline of the indoor unit 107 or more 183 or more 1,500 or more A: Install so that the flare connection part is outdoors. - 57 - 4-5.
  • Page 66 ¢ Models: ASHG07–14KGTE, ASHG07–14KGTF, ASHH07– 14KGTG, and ASHH07–14KGTH Unit: mm (834) Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 - 58 - 4-5. Wall mounted type 4. Dimensions...
  • Page 67  Installation space requirement Provide sufficient installation space for product safety. Unit: mm 40 or more 70 or more Wall hook bracket 107 or more 183 or more Outline of the indoor unit 1,500 or more A: Install so that the flare connection part is outdoors. - 59 - 4-5.
  • Page 68 ¢ Models: ASHH05–12KNCA and ASHH05–12KNCH Unit: mm Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 - 60 - 4-5. Wall mounted type 4. Dimensions...
  • Page 69  Installation space requirement Provide sufficient installation space for product safety. Unit: mm 30 or more 40 or more Wall hook bracket 107 or more Outline of the indoor unit 163 or more 1,500 or more - 61 - 4-5. Wall mounted type 4.
  • Page 70 ¢ Model: ASHG18KMTB Unit: mm Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 - 62 - 4-5. Wall mounted type 4. Dimensions...
  • Page 71  Installation space requirement Provide sufficient installation space for product safety. Unit: mm 40 or more Wall hook bracket 70 or more Outline of the indoor unit 160 or more 117 or more 1,500 or more A: Install so that the flare connection part is outdoors. - 63 - 4-5.
  • Page 72 ¢ Model: ASHG18KMTE Unit: mm Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 - 64 - 4-5. Wall mounted type 4. Dimensions...
  • Page 73  Installation space requirement Provide sufficient installation space for product safety. Unit: mm 40 or more Wall hook bracket 70 or more 117 or more Outline of the indoor unit 160 or more 1,500 or more A: Install so that the flare connection part is outdoors. - 65 - 4-5.
  • Page 74 ¢ Pipe exit length from the rear (for KMCG, KMCG-B, KMCH, KMCH-B, KGTG, KGTH, KNCA, and KNCH) Design the system considering the length of the pipes or hose exiting from the rear of the indoor unit. NOTE: Detailed shapes of the indoor unit and the tip of each pipe or hose may vary depending on the model.
  • Page 75: Ceiling Type

    4-6. Ceiling type ¢ Model: ABHG18KRTA Unit: mm 1,080 49 84 125 103 Side view Top view ø100-mm hole Rear view Suspension bolt pitch Dimensions Indoor unit (Top view) (Space required for installation) The length of the bolt here is 30 mm. Indoor unit - 67 - 4-6.
  • Page 76 ¢ Installation space requirement Unit: mm Ceiling Indoor unit 30 or more Ceiling 200 or more 0 or more Obstruction Floor Required ceiling height varies according to the ceiling mode setting of function setting No. 20. Ceiling height (mm) Ceiling mode Standard High ceiling 18 model...
  • Page 77: Floor Type

    4-7. Floor type ¢ Models: AGHG09–14KVCA Unit: mm Side view Front view - 69 - 4-7. Floor type 4. Dimensions...
  • Page 78: Installation Space

     Installation space Unit: mm 100 or more 80 or more 80 or more 50 or more 150 or below from the floor PROHIBITED Grating WARNING • The appliance shall be installed, operated and stored in a room with a floor area larger than X Minimum room area Amount of refrigerant charge M (kg)
  • Page 79: Wiring Diagrams

    5. Wiring diagrams 5-1. Compact cassette type ¢ Models: AUXG07–18KVLA - 71 - 5-1. Compact cassette type 5. Wiring diagrams...
  • Page 80: Mini Duct Type And Slim Duct Type

    5-2. Mini duct type and Slim duct type ¢ Models: ARXG07–18KSLAP and ARXG07–18KLLAP WLAN adapter, Converter etc. (Option) - 72 - 5-2. Mini duct type and Slim duct type 5. Wiring diagrams...
  • Page 81: Medium Static Pressure Duct Type

    5-3. Medium static pressure duct type ¢ Models: ARXH12–18KMTAP - 73 - 5-3. Medium static pressure duct type 5. Wiring diagrams...
  • Page 82: Wall Mounted Type

    5-4. Wall mounted type ¢ Models: ASHG07–14KMTB - 74 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 83 ¢ Models: ASHG07–14KMCC - 75 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 84 ¢ Models: ASHG07–14KMCE, ASHH07–14KMCH, and ASHH07– 14KMCH-B - 76 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 85 ¢ Models: ASHG07–14KMCF, ASHH07–14KMCG, and ASHH07– 14KMCG-B - 77 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 86 ¢ Models: ASHG07–14KETA and ASHG07–14KETA-B - 78 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 87 ¢ Models: ASHG07–14KETE and ASHG07–14KETE-B - 79 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 88 ¢ Models: ASHG07–14KETF and ASHG07–14KETF-B - 80 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 89 ¢ Models: ASHG07–14KGTB - 81 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 90 ¢ Models: ASHG07–14KGTE and ASHH07–14KGTH - 82 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 91 ¢ Models: ASHG07–14KGTF and ASHH07–14KGTG - 83 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 92 ¢ Models: ASHH05–12KNCA - 84 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 93 ¢ Models: ASHH05–12KNCH - 85 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 94 ¢ Model: ASHG18KMTB - 86 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 95 ¢ Model: ASHG18KMTE - 87 - 5-4. Wall mounted type 5. Wiring diagrams...
  • Page 96: Ceiling Type

    5-5. Ceiling type ¢ Model: ABHG18KRTA - 88 - 5-5. Ceiling type 5. Wiring diagrams...
  • Page 97: Floor Type

    5-6. Floor type ¢ Models: AGHG09–14KVCA - 89 - 5-6. Floor type 5. Wiring diagrams...
  • Page 98: Air Velocity And Temperature Distributions

    6. Air velocity and temperature distributions 6-1. Compact cassette type ¢ Models: AUXG07–09KVLA • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH Unit : m/s 0.25 0.25 Top view Horizontal louver: Up 0.25 0.25 4 (m) Unit : m/s Side view Horizontal louver: Up 0.25...
  • Page 99 • Air velocity distribution Fan speed Operation mode Outlet directions Measuring conditions NOTE: Reference data HIGH HEAT 4-way air outlet Unit : m/s Side view Horizontal louver: Down 0.25 0.25 4 (m) • Air temperature distribution Fan speed Operation mode Outlet directions Measuring conditions NOTE: Reference data...
  • Page 100 ¢ Model: AUXG12KVLA • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH Unit : m/s 0.25 0.25 Top view Horizontal louver: Up 0.25 0.25 4 (m) Unit : m/s Side view Horizontal louver: Up 0.25 0.25 4 (m) - 92 - 6-1.
  • Page 101 • Air velocity distribution Fan speed Operation mode Outlet directions Measuring conditions NOTE: Reference data HIGH HEAT 4-way air outlet Unit : m/s Side view Horizontal louver: Down 0.25 0.25 4 (m) • Air temperature distribution Fan speed Operation mode Outlet directions Measuring conditions NOTE: Reference data...
  • Page 102 ¢ Model: AUXG14KVLA • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH Unit : m/s 0.25 Top view Horizontal louver: Up 0.25 0.25 0.25 4 (m) Unit : m/s Side view Horizontal louver: Up 0.25 0.25 4 (m) - 94 - 6-1.
  • Page 103 • Air velocity distribution Fan speed Operation mode Outlet directions Measuring conditions NOTE: Reference data HIGH HEAT 4-way air outlet Unit : m/s Side view Horizontal louver: Down 0.25 4 (m) • Air temperature distribution Fan speed Operation mode Outlet directions Measuring conditions NOTE: Reference data HIGH...
  • Page 104 ¢ Model: AUXG18KVLA Fan speed Operation mode Ceiling mode Measuring conditions HIGH STANDARD Unit: m/s 0.25 Top view Horizontal louver: Up 0.25 0.25 0.25 Unit: m/s Side view Horizontal louver: Up 0.25 0.25 Unit: m/s Side view Horizontal louver: Down 0.25 0.25 - 96 -...
  • Page 105: Mini Duct Type

    6-2. Mini duct type ¢ Model: ARXG07KSLAP NOTE: This data is measured after installing optional Auto louver grille kit. • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up...
  • Page 106 • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: m/s Side view Horizontal louver: Down Vertical louver: Center • Air temperature distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: °C Side view Horizontal louver: Down Vertical louver: Center - 98 - 6-2.
  • Page 107 ¢ Model: ARXG09KSLAP NOTE: This data is measured after installing optional Auto Louver Grille Kit. • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left &...
  • Page 108 • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: m/s Side view Horizontal louver: Down Vertical louver: Center • Air temperature distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: °C Side view Horizontal louver: Down Vertical louver: Center - 100 - 6-2.
  • Page 109 ¢ Model: ARXG12KSLAP NOTE: This data is measured after installing optional Auto Louver Grille Kit. • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left &...
  • Page 110 • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: m/s Side view Horizontal louver: Down Vertical louver: Center • Air temperature distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: °C Side view Horizontal louver: Down Vertical louver: Center - 102 - 6-2.
  • Page 111 ¢ Model: ARXG14KSLAP NOTE: This data is measured after installing optional Auto louver grille kit. • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left &...
  • Page 112 • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: m/s Side view Horizontal louver: Down Vertical louver: Center • Air temperature distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: °C Side view Horizontal louver: Down Vertical louver: Center - 104 - 6-2.
  • Page 113 ¢ Model: ARXG18KSLAP NOTE: This data is measured after installing optional Auto Louver Grille Kit. • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left &...
  • Page 114 • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: m/s Side view Horizontal louver: Down Vertical louver: Center • Air temperature distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: °C Side view Horizontal louver: Down Vertical louver: Center - 106 - 6-2.
  • Page 115: Slim Duct Type

    6-3. Slim duct type ¢ Model: ARXG07KLLAP NOTE: This data is measured after installing optional Auto louver grille kit. • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up...
  • Page 116 • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: m/s Side view Horizontal louver: Down Vertical louver: Center • Air temperature distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: °C Side view Horizontal louver: Down Vertical louver: Center - 108 - 6-3.
  • Page 117 ¢ Model: ARXG09KLLAP NOTE: This data is measured after installing optional Auto louver grille kit. • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left &...
  • Page 118 • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: m/s Side view Horizontal louver: Down Vertical louver: Center • Air temperature distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: °C Side view Horizontal louver: Down Vertical louver: Center - 110 - 6-3.
  • Page 119 ¢ Model: ARXG12KLLAP NOTE: This data is measured after installing optional Auto louver grille kit. • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left &...
  • Page 120 • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: m/s Side view Horizontal louver: Down Vertical louver: Center • Air temperature distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: °C Side view Horizontal louver: Down Vertical louver: Center - 112 - 6-3.
  • Page 121 ¢ Model: ARXG14KLLAP NOTE: This data is measured after installing optional Auto louver grille kit. • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left &...
  • Page 122 • Air velocity distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: m/s Side view Horizontal louver: Down Vertical louver: Center • Air temperature distribution Fan speed Operation mode Measuring conditions HIGH HEAT Unit: °C Side view Horizontal louver: Down Vertical louver: Center - 114 - 6-3.
  • Page 123 ¢ Model: ARXG18KLLAP NOTE: This data is measured after installing optional Auto Louver Grille Kit. Fan speed Operation mode Measuring conditions HIGH • Air velocity distribution Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left &...
  • Page 124 Fan speed Operation mode Measuring conditions HIGH HEAT • Air velocity distribution Unit: m/s Side view Horizontal louver: Down Vertical louver: Center • Air temperature distribution Unit: °C Side view Horizontal louver: Down Vertical louver: Center - 116 - 6-3. Slim duct type 6.
  • Page 125: Wall Mounted Type

    6-4. Wall mounted type ¢ Models: ASHG07–12KMTB, ASHG07–12KMCC, ASHG07– 12KMCE, ASHG07–12KMCF, ASHH07–12KMCG, ASHH07– 12KMCG-B, ASHH07–12KMCH, ASHH07–12KMCH-B, ASHG07– 12KETA, ASHG07–12KETA-B, ASHG07–12KETE, ASHG07– 12KETE-B, ASHG07–12KETF, ASHG07–12KETF-B, ASHG07– 09KGTB, ASHG07–09KGTE, ASHG07–09KGTF, ASHH07– 09KGTG, and ASHH07–09KGTH Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center...
  • Page 126 ¢ Models: ASHG14KMTB, ASHG14KMCC, ASHG14KMCE, ASHG14KMCF, ASHH14KMCG, ASHH14KMCG-B, ASHH14KMCH, ASHH14KMCH-B, ASHG14KETA, ASHG14KETA- B, ASHG14KETE, ASHG14KETE-B, ASHG14KETF, ASHG14KETF-B, ASHG12–14KGTB, ASHG12–14KGTE, ASHG12–14KGTF, ASHH12–14KGTG, and ASHH12–14KGTH Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up...
  • Page 127 ¢ Models: ASHH05KNCA and ASHH05KNCH Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left & Right Unit: m/s Side view Horizontal louver: Up Vertical louver: Center Unit: m/s Side view...
  • Page 128 ¢ Models: ASHH07KNCA and ASHH07KNCH Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left & Right Unit: m/s Side view Horizontal louver: Up Vertical louver: Center Unit: m/s Side view...
  • Page 129 ¢ Models: ASHH09KNCA and ASHH09KNCH Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left & Right Unit: m/s Side view Horizontal louver: Up Vertical louver: Center Unit: m/s Side view...
  • Page 130 ¢ Models: ASHH12KNCA and ASHH12KNCH Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left & Right Unit: m/s Side view Horizontal louver: Up Vertical louver: Center Unit: m/s Side view...
  • Page 131 ¢ Models: ASHG18KMTB and ASHG18KMTE Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left & Right Unit: m/s Side view Horizontal louver: Up Vertical louver: Center Unit: m/s Side view...
  • Page 132: Ceiling Type

    6-5. Ceiling type ¢ Model: ABHG18KRTA Fan speed Operation mode Measuring conditions HIGH Unit: m/s 0.25 Top view Horizontal louver: Up Vertical louver: Center Unit: m/s 0.25 Top view Horizontal louver: Up Vertical louver: Left & Right 0.25 Unit: m/s Side view 0.25 Horizontal louver: Up...
  • Page 133: Floor Type

    6-6. Floor type ¢ Models: AGHG09–14KVCA Fan speed Operation mode Fan select Measuring conditions HIGH Upper and lower Unit: m/s Top view Horizontal louver: Up Vertical louver: Center UPPER LOWER Unit: m/s Top view Horizontal louver: Up Vertical louver: Left & Right Unit: m/s Side view Horizontal louver: Up...
  • Page 134: Fan Performance

    7. Fan performance NOTE: Airflow and capacity/outlet temperature curve data are measured based on the same condi- tions mentioned in "Specifications". 7-1. Mini duct type ¢ Model: ARXG07KSLAP Quiet (SP mode 00) SP mode 03 upper limit Quiet (Normal SP) Quiet (SP mode 03) Hi (SP mode 03) Normal SP upper limit...
  • Page 135  Characteristics of air volume and capacity • Cooling Capacity Airflow (m • Heating Capacity Airflow (m - 127 - 7-1. Mini duct type 7. Fan performance...
  • Page 136 ¢ Model: ARXG09KSLAP Quiet (SP mode 00) SP mode 03 upper limit Quiet (Normal SP) Hi (SP mode 03) Quiet (SP mode 03) SP mode 00 upper limit SP mode 03 lower limit Normal SP upper limit Hi (Normal SP) Hi (SP mode 00) Airflow (m Available airflow rate range (High level)
  • Page 137  Characteristics of air volume and capacity • Cooling Capacity Airflow (m • Heating Capacity Airflow (m - 129 - 7-1. Mini duct type 7. Fan performance...
  • Page 138 ¢ Model: ARXG12KSLAP SP mode 03 upper limit Quiet (SP mode 03) Hi (SP mode 03) Quiet Normal SP (Normal SP) upper limit Quiet SP mode 03 (SP mode 00) lower limit SP mode 00 (Normal SP) upper limit Hi (SP mode 00) Airflow (m Available airflow rate range (High level) Hi (SP mode 03)
  • Page 139  Characteristics of air volume and capacity • Cooling Capacity Airflow (m • Heating Capacity Airflow (m - 131 - 7-1. Mini duct type 7. Fan performance...
  • Page 140 ¢ Model: ARXG14KSLAP Hi (SP mode 05) SP mode 05 upper limit Quiet (SP mode 00) Nomal SP Quiet upper limit (Nomal SP) Quiet Hi (Normal SP) (SP mode 05) SP mode 05 lower limit SP mode 00 upper limit (SP mode 00) Airflow (m Available airflow rate range (High level)
  • Page 141  Characteristics of air volume and capacity • Cooling Capacity Airflow (m • Heating Capacity Airflow (m - 133 - 7-1. Mini duct type 7. Fan performance...
  • Page 142 ¢ Model: ARXG18KSLAP SP mode 05 Hi (SP mode 05) upper limit Quiet (SP mode 05) SP mode 05 lower limit Quiet (Normal SP) Quiet (SP mode 00) Normal SP upper limit Hi (Normal SP) Hi (SP mode 00) SP mode 00 upper limit 1,000 1,100...
  • Page 143  Characteristics of air volume and capacity • Cooling Capacity 1,000 1,100 Airflow (m • Heating Capacity 1,000 1,100 Airflow (m - 135 - 7-1. Mini duct type 7. Fan performance...
  • Page 144: Slim Duct Type

    7-2. Slim duct type ¢ Model: ARXG07KLLAP Hi (SP mode 09) SP mode 09 upper limit Quiet (SP mode 09) SP mode 09 lower limit Normal SP upper limit Quiet (Normal SP) Hi (Normal SP) SP mode 00 Normal SP upper limit lower limited Quiet (SP mode 00)
  • Page 145  Characteristics of air volume and capacity • Cooling Capacity Airflow (m • Heating Capacity Airflow (m - 137 - 7-2. Slim duct type 7. Fan performance...
  • Page 146 ¢ Model: ARXG09KLLAP Hi (SP mode 09) SP mode 09 upper limit Quiet (SP mode 09) SP mode 09 lower limit Normal SP upper limit Quiet (Normal SP) Hi (Normal SP) Hi (SP mode00) SP mode 00 upper limit Quiet (SP mode 00) Airflow (m Available airflow rate range (High level) Hi (SP mode 09)
  • Page 147  Characteristics of air volume and capacity • Cooling Capacity Airflow (m • Heating Capacity Airflow (m - 139 - 7-2. Slim duct type 7. Fan performance...
  • Page 148 ¢ Model: ARXG12KLLAP SP mode 09 upper limit Hi (SP mode 09) Quiet (SP mode 09) SP mode 09 lower limit Normal SP upper limit Quiet (Normal SP) Hi (Normal SP) SP mode 00 Hi (SP mode 00) upper limit Quiet (SP mode 00) Airflow (m Available airflow rate range (High level)
  • Page 149  Characteristics of air volume and capacity • Cooling Capacity Airflow (m • Heating Capacity Airflow (m - 141 - 7-2. Slim duct type 7. Fan performance...
  • Page 150 ¢ Model: ARXG14KLLAP SP mode 09 upper limit Hi (SP mode 09) Quiet (SP mode 09) Nomal SP upper limit SP mode 09 lower limit Quiet (Nomal SP) Hi (Normal SP) SP mode 00 upper limit Hi (SP mode 00) Quiet (SP mode 00) 1,000...
  • Page 151  Characteristics of air volume and capacity • Cooling Capacity 1,000 Airflow (m • Heating Capacity 1,000 Airflow (m - 143 - 7-2. Slim duct type 7. Fan performance...
  • Page 152 ¢ Model: ARXG18KLLAP SP mode 09 upper limit Hi (SP mode 09) Quiet (SP mode 09) SP mode 09 lower limit Normal SP upper limit Quiet (Normal SP) SP mode 00 Hi (Normal SP) upper limit Hi (SP mode 00) Quiet (SP mode 00) 1,000 1,100...
  • Page 153  Characteristics of air volume and capacity • Cooling Capacity 1,000 1,100 Airflow (m • Heating Capacitty 1,000 1,100 Airflow (m - 145 - 7-2. Slim duct type 7. Fan performance...
  • Page 154: Medium Static Pressure Duct Type

    7-3. Medium static pressure duct type ¢ Model: ARXH12KMTAP Fan performance curve 1 Hi (SP mode 15) SP mode 15 upper limit SP mode 15 lower limit Me (SP mode 15) Lo (SP mode 15) Standard SP upper limit SP mode 03 Qu (SP mode 15) upper limit Hi (Standard SP)
  • Page 155  Characteristics of air volume and capacity • Cooling 1,050 1,150 Airflow (m • Heating 1,050 1,150 Airflow (m - 147 - 7-3. Medium static pressure duct type 7. Fan performance...
  • Page 156 ¢ Model: ARXH14KMTAP Fan performance curve 1 Hi (SP mode 15) SP mode 15 upper limit SP mode 15 lower limit Me (SP mode 15) Lo (SP mode 15) Standard SP upper limit SP mode 03 upper limit Qu (SP mode 15) Hi (Standard SP) Me (Standard SP) Standard SP...
  • Page 157  Characteristics of air volume and capacity • Cooling 1,000 1,100 1,200 1,300 Airflow (m • Heating 1,000 1,100 1,200 1,300 Airflow (m - 149 - 7-3. Medium static pressure duct type 7. Fan performance...
  • Page 158 ¢ Model: ARXH18KMTAP Fan performance curve 1 Hi (SP mode 15) SP mode 15 upper limit SP mode 15 Me (SP mode 15) lower limit Lo (SP mode 15) Standard SP upper limit Qu (SP mode 15) SP mode 03 upper limit Hi (Standard SP) Me (Standard SP) Standard SP...
  • Page 159  Characteristics of air volume and capacity • Cooling 1,040 1,140 1,240 1,340 Airflow (m • Heating 1,040 1,140 1,240 1,340 Airflow (m - 151 - 7-3. Medium static pressure duct type 7. Fan performance...
  • Page 160: Compact Cassette Type

    8. Airflow Conversion factor: • 1 m /h = 0.2778 l/s = 0.5886 CFM • 3.6 m /h = 1 l/s • 1.699 m /h = 1 CFM 8-1. Compact cassette type Airflow Model Operation mode Fan speed High Cooling AUXG07KVLA Quiet AUXG09KVLA...
  • Page 161: Mini Duct Type

    8-2. Mini duct type Airflow Model Operation mode Fan speed High Cooling Quiet ARXG07KSLAP High Heating Quiet High Cooling Quiet ARXG09KSLAP High Heating Quiet High Cooling Quiet ARXG12KSLAP High Heating Quiet High Cooling Quiet ARXG14KSLAP High Heating Quiet High Cooling Quiet ARXG18KSLAP High...
  • Page 162: Slim Duct Type

    8-3. Slim duct type Airflow Model Operation mode Fan speed High Cooling Quiet ARXG07KLLAP High Heating Quiet High Cooling Quiet ARXG09KLLAP High Heating Quiet High Cooling Quiet ARXG12KLLAP High Heating Quiet High Cooling Quiet ARXG14KLLAP High Heating Quiet High Cooling Quiet ARXG18KLLAP High...
  • Page 163: Medium Static Pressure Duct Type

    8-4. Medium static pressure duct type Airflow Model Operation mode Fan speed High Cooling Quiet ARXH12KMTAP High Heating Quiet High Cooling Quiet ARXH14KMTAP High Heating Quiet High Cooling Quiet ARXH18KMTAP High Heating Quiet - 155 - 8-4. Medium static pressure duct type 8.
  • Page 164: Wall Mounted Type

    8-5. Wall mounted type Airflow Model Operation mode Fan speed High Cooling Quiet ASHG07KMTB High Heating Quiet High Cooling Quiet ASHG09KMTB High Heating Quiet High Cooling Quiet ASHG12KMTB High Heating Quiet High Cooling Quiet ASHG14KMTB High Heating Quiet High Cooling Quiet ASHG07KMCC High...
  • Page 165 Airflow Model Operation mode Fan speed High Cooling Quiet ASHG12KMCC High Heating Quiet High Cooling Quiet ASHG14KMCC High Heating Quiet High Cooling Quiet ASHG07KMCE High Heating Quiet High Cooling Quiet ASHG09KMCE High Heating Quiet High Cooling Quiet ASHG12KMCE High Heating Quiet High Cooling...
  • Page 166 Airflow Model Operation mode Fan speed High Cooling Quiet ASHG07KMCF High Heating Quiet High Cooling Quiet ASHG09KMCF High Heating Quiet High Cooling Quiet ASHG12KMCF High Heating Quiet High Cooling Quiet ASHG14KMCF High Heating Quiet High Cooling ASHH07KMCG Quiet High ASHH07KMCG-B Heating Quiet High...
  • Page 167 Airflow Model Operation mode Fan speed High Cooling ASHH12KMCG Quiet ASHH12KMCG-B High Heating Quiet High Cooling ASHH14KMCG Quiet High ASHH14KMCG-B Heating Quiet High Cooling ASHH07KMCH Quiet ASHH07KMCH-B High Heating Quiet High Cooling ASHH09KMCH Quiet High ASHH09KMCH-B Heating Quiet High Cooling ASHH12KMCH Quiet High...
  • Page 168 Airflow Model Operation mode Fan speed High Cooling ASHG07KETA Quiet ASHG07KETA-B High Heating Quiet High Cooling ASHG09KETA Quiet High ASHG09KETA-B Heating Quiet High Cooling ASHG12KETA Quiet ASHG12KETA-B High Heating Quiet High Cooling ASHG14KETA Quiet High ASHG14KETA-B Heating Quiet High Cooling ASHG07KETE Quiet High...
  • Page 169 Airflow Model Operation mode Fan speed High Cooling ASHG12KETE Quiet ASHG12KETE-B High Heating Quiet High Cooling ASHG14KETE Quiet High ASHG14KETE-B Heating Quiet High Cooling ASHG07KETF Quiet ASHG07KETF-B High Heating Quiet High Cooling ASHG09KETF Quiet High ASHG09KETF-B Heating Quiet High Cooling ASHG12KETF Quiet High...
  • Page 170 Airflow Model Operation mode Fan speed High Cooling Quiet ASHG07KGTB High Heating Quiet High Cooling Quiet ASHG09KGTB High Heating Quiet High Cooling Quiet ASHG12KGTB High Heating Quiet High Cooling Quiet ASHG14KGTB High Heating Quiet High Cooling Quiet ASHG07KGTE High Heating Quiet High Cooling...
  • Page 171 Airflow Model Operation mode Fan speed High Cooling Quiet ASHG12KGTE High Heating Quiet High Cooling Quiet ASHG14KGTE High Heating Quiet High Cooling Quiet ASHG07KGTF High Heating Quiet High Cooling Quiet ASHG09KGTF High Heating Quiet High Cooling Quiet ASHG12KGTF High Heating Quiet High Cooling...
  • Page 172 Airflow Model Operation mode Fan speed High Cooling Quiet ASHH07KGTG High Heating Quiet High Cooling Quiet ASHH09KGTG High Heating Quiet High Cooling Quiet ASHH12KGTG High Heating Quiet High Cooling Quiet ASHH14KGTG High Heating Quiet High Cooling Quiet ASHH07KGTH High Heating Quiet High Cooling...
  • Page 173 Airflow Model Operation mode Fan speed High Cooling Quiet ASHH12KGTH High Heating Quiet High Cooling Quiet ASHH14KGTH High Heating Quiet High Cooling Quiet ASHH05KNCA High Heating Quiet High Cooling Quiet ASHH07KNCA High Heating Quiet High Cooling Quiet ASHH09KNCA High Heating Quiet High Cooling...
  • Page 174 Airflow Model Operation mode Fan speed High Cooling Quiet ASHH05KNCH High Heating Quiet High Cooling Quiet ASHH07KNCH High Heating Quiet High Cooling Quiet ASHH09KNCH High Heating Quiet High Cooling Quiet ASHH12KNCH High Heating Quiet High Cooling Quiet ASHG18KMTB High 1,020 Heating Quiet High...
  • Page 175: Ceiling Type

    8-6. Ceiling type Airflow Model Operation mode Fan speed High Cooling Quiet ABHG18KRTA High Heating Quiet - 167 - 8-6. Ceiling type 8. Airflow...
  • Page 176: Floor Type

    8-7. Floor type Airflow Model Operation mode Fan speed High Cooling Quiet AGHG09KVCA High Heating Quiet High Cooling Quiet AGHG12KVCA High Heating Quiet High Cooling Quiet AGHG14KVCA High Heating Quiet - 168 - 8-7. Floor type 8. Airflow...
  • Page 177: Noise Level Curve

    9. Noise level curve 9-1. Compact cassette type ¢ Model: AUXG07KVLA  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 HIGH NC-45 NC-45 HIGH NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 QUIET QUIET NC-20 NC-20 NC-15 NC-15 1,000 2,000...
  • Page 178 ¢ Model: AUXG12KVLA  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 HIGH NC-45 NC-45 HIGH NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 QUIET QUIET NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000 Octave band center frequency, Hz Octave band center frequency, Hz...
  • Page 179 ¢ Model: AUXG18KVLA  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 HIGH HIGH NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 QUIET NC-25 QUIET NC-25 NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000 Octave band center frequency, Hz Octave band center frequency, Hz...
  • Page 180: Mini Duct Type

    9-2. Mini duct type ¢ Model: ARXG07KSLAP  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 HIGH NC-35 NC-35 HIGH NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 QUIET QUIET 1,000 2,000 4,000 8,000 1,000 2,000...
  • Page 181 ¢ Model: ARXG12KSLAP  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 HIGH HIGH NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 QUIET QUIET NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000 Octave band center frequency ,Hz Octave band center frequency ,Hz...
  • Page 182 ¢ Model: ARXG18KSLAP  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 HIGH HIGH NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 QUIET QUIET NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000 Octave band center frequency ,Hz Octave band center frequency ,Hz...
  • Page 183: Slim Duct Type

    9-3. Slim duct type ¢ Model: ARXG07KLLAP  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 HIGH HIGH NC-30 NC-30 NC-25 NC-25 QUIET QUIET NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000...
  • Page 184 ¢ Model: ARXG12KLLAP  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 HIGH HIGH NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 QUIET NC-20 NC-20 QUIET NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000 Octave band center frequency, Hz Octave band center frequency, Hz...
  • Page 185 ¢ Model: ARXG18KLLAP  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 HIGH NC-45 NC-40 NC-40 HIGH NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 QUIET NC-20 QUIET NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000 Octave band center frequency, Hz Octave band center frequency, Hz...
  • Page 186: Medium Static Pressure Duct Type

    9-4. Medium static pressure duct type ¢ Model: ARXH12KMTAP  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 HIGH NC-30 NC-30 HIGH NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 QUIET QUIET 1,000 2,000 4,000 8,000...
  • Page 187 ¢ Model: ARXH18KMTAP  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 HIGH NC-35 NC-35 HIGH NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 QUIET NC-15 NC-15 QUIET 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000 Octave band center frequency, Hz Octave band center frequency, Hz...
  • Page 188: Wall Mounted Type

    9-5. Wall mounted type ¢ Models: ASHG07KMTB, ASHG07KMCC, ASHG07KMCE, ASHG07KMCF, ASHH07KMCG, ASHH07KMCG-B, ASHH07KMCH, ASHH07KMCH-B, ASHG07KETA, ASHG07KETA- B, ASHG07KETE, ASHG07KETE-B, ASHG07KETF, and ASHG07KETF-B  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 HIGH NC-45 NC-45 HIGH NC-40 NC-40 NC-35 NC-35 NC-30...
  • Page 189 ¢ Models: ASHG09KMTB, ASHG09KMCC, ASHG09KMCE, ASHG09KMCF, ASHH09KMCG, ASHH09KMCG-B, ASHH09KMCH, ASHH09KMCH-B, ASHG09KETA, ASHG09KETA- B, ASHG09KETE, ASHG09KETE-B, ASHG09KETF, and ASHG09KETF-B  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 HIGH HIGH NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20...
  • Page 190 ¢ Models: ASHG12KMTB, ASHG12KMCC, ASHG12KMCE, ASHG12KMCF, ASHH12KMCG, ASHH12KMCG-B, ASHH12KMCH, ASHH12KMCH-B, ASHG12KETA, ASHG12KETA- B, ASHG12KETE, ASHG12KETE-B, ASHG12KETF, and ASHG12KETF-B  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 HIGH NC-45 NC-45 HIGH NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20...
  • Page 191 ¢ Models: ASHG14KMTB, ASHG14KMCC, ASHG14KMCE, ASHG14KMCF, ASHH14KMCG, ASHH14KMCG-B, ASHH14KMCH, ASHH14KMCH-B, ASHG14KETA, ASHG14KETA- B, ASHG14KETE, ASHG14KETE-B, ASHG14KETF, and ASHG14KETF-B  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 HIGH HIGH NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20...
  • Page 192 ¢ Models: ASHG09KGTB, ASHG09KGTE, ASHG09KGTF, ASHH09KGTG, and ASHH09KGTH  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 HIGH HIGH NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 QUIET QUIET 1,000 2,000 4,000 8,000 1,000...
  • Page 193 ¢ Models: ASHG14KGTB, ASHG14KGTE, ASHG14KGTF, ASHH14KGTG, and ASHH14KGTH  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 HIGH HIGH NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 QUIET QUIET 1,000 2,000 4,000 8,000 1,000...
  • Page 194 ¢ Models: ASHH07KNCA and ASHH07KNCH  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 HIGH HIGH NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 QUIET NC-15 NC-15 QUIET 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000...
  • Page 195 ¢ Models: ASHH12KNCA and ASHH12KNCH  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 HIGH NC-45 NC-45 HIGH NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 QUIET NC-15 QUIET 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000...
  • Page 196: Ceiling Type

    9-6. Ceiling type ¢ Model: ABHG18KRTA  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 HIGH HIGH NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 QUIET QUIET NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000...
  • Page 197: Floor Type

    9-7. Floor type ¢ Model: AGHG09KVCA  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 HIGH HIGH NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 QUIET QUIET NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000...
  • Page 198 ¢ Model: AGHG14KVCA  Cooling  Heating NC-65 NC-65 NC-60 NC-60 HIGH NC-55 NC-55 HIGH NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 QUIET QUIET NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000 Octave band center frequency, Hz Octave band center frequency, Hz...
  • Page 199: Sound Level Check Point

    9-8. Sound level check point ¢ Compact cassette type Microphone 1.5 m Microphone - 191 - 9-8. Sound level check point 9. Noise level curve...
  • Page 200 ¢ Mini duct type , Slim duct type, and Medium static pressure duct type Product Measuring duct Measuring duct (Set the static pressure as rating in this area.) Microphone Microphone Front view Side view NOTE: Detailed shape of the actual indoor unit might be slightly different from the one illustrated above.
  • Page 201 ¢ Floor type Microphone Microphone ● ● Airflow Airflow - 193 - 9-8. Sound level check point 9. Noise level curve...
  • Page 202: Electrical Characteristics

    10. Electrical characteristics Power supply Wiring spec. of connection cable Indoor rated (50 Hz, 230 V) (Indoor unit to outdoor unit) Input Cross- sectional Limited wiring power area length Type Model name AUXG07KVLA 0.19 0.15 AUXG09KVLA 0.19 0.15 AUXG12KVLA 0.24 0.19 Compact cassette...
  • Page 203 Power supply Wiring spec. of connection cable Indoor rated (50 Hz, 230 V) (Indoor unit to outdoor unit) Input Cross- sectional Limited wiring power area length Type Model name ASHH07KMCH 0.25 0.20 ASHH07KMCH-B ASHH09KMCH 0.30 0.24 ASHH09KMCH-B Wall mounted ASHH12KMCH 0.30 0.24 ASHH12KMCH-B...
  • Page 204 Power supply Wiring spec. of connection cable Indoor rated (50 Hz, 230 V) (Indoor unit to outdoor unit) Input Cross- sectional Limited wiring power area length Type Model name ASHH07KGTH 0.25 0.20 ASHH09KGTH 0.30 0.24 Wall mounted ASHH12KGTH 0.30 0.24 ASHH14KGTH 0.37 0.29...
  • Page 205: Safety Devices

    11. Safety devices Terminal Indoor unit Float Model name PCB* fuse Fan motor thermal protector thermal type switch fuse AUXG07KVLA AUXG09KVLA Activate: 100 ±15 °C Fan motor stop AUXG12KVLA Compact cassette Reset: 95 ±10 °C AUXG14KVLA AUXG18KVLA Fan motor restart AUXG22KVLA ARXG07KSLAP ARXG09KSLAP...
  • Page 206 Terminal Indoor unit Float Model name PCB* fuse Fan motor thermal protector thermal type switch fuse ASHH07KMCG ASHH07KMCG-B Activate: 170 °C ASHH09KMCG Fan motor stop ASHH09KMCG-B Wall mounted 250 V, 3.15 A ― ― ASHH12KMCG Reset: 145 °C ASHH12KMCG-B Fan motor restart ASHH14KMCG ASHH14KMCG-B ASHH07KMCH...
  • Page 207 Terminal Indoor unit Float Model name PCB* fuse Fan motor thermal protector thermal type switch fuse ASHG07KGTE Activate: 110 ±15 °C Fan motor speed down Reset: 110 ±15 °C ASHG09KGTE Fan motor speed recover Wall mounted 250 V, 3.15 A 102 °C Off ―...
  • Page 208 Terminal Indoor unit Float Model name PCB* fuse Fan motor thermal protector thermal type switch fuse AGHG09KVCA Activate: 150 ±15 °C Fan motor stop AGHG12KVCA Floor 250V, 5.0 A 110 °C Off ― Reset: 120 ±15 °C AGHG14KVCA Fan motor restart *: Printed Circuit Board - 200 - 11.
  • Page 209: External Input And Output

    12. External input and output 12-1. Compact cassette type, Medium static pressure duct type, and Ceiling type • Compact cassette type and Ceiling type CN71 Rotary switch CN14 CN65 CN47 CN46 (Ext. I/O PCB) (Ext. out) (Ext. in) Terminal (Ext. in) Fig.
  • Page 210: Indoor Unit

    ¢ External input With using external input function, some functions on this product can be controlled from an external device. • “Operation/Stop” mode or "Forced stop" mode can be selected with function setting of indoor unit. • A twisted pair cable should be used. Maximum length of cable is 150 m. •...
  • Page 211: Input Signal Type

     Input signal type • Indoor unit Input signal type is only "Edge". Edge • External Input and Output PCB The input signal type can be selected. Signal type (edge or pulse) can be switched by the DIP switch 2 (SW2) on the External Input and Output PCB.
  • Page 212: External Output

    ¢ External output Use an external output cable with appropriate external dimension, depending on the number of ca- bles to be installed.  Indoor unit • A twisted pair cable (22 AWG) should be used. Maximum length of cable is 25 m. •...
  • Page 213 ¢ Setting of external input and output • Indoor unit Input Connecting point Function setting number 46 Function Operation/Stop mode 1 (Setting prohibited) Terminal Forced stop mode Operation/Stop mode 2 Output Connecting point Function setting number 60 Function Operation/Stop 01 to 08 (Setting prohibited) CN47 Error status...
  • Page 214 ¢ Details of control input function  Operation/Stop mode 1 • In the case of "Edge" input External Input and Output PCB Function External input Input signal Command setting Rotary switch Off → On Operation — Input of indoor unit Terminal On →...
  • Page 215: Function Setting

     Forced stop • In the case of "Edge" input External Input and Output PCB Function External input Input signal Command setting Rotary switch Forced stop Off → On (R.C. disabled) — Input of indoor unit Terminal Normal On → Off (R.C.
  • Page 216: Operation/Stop Mode

     Operation/Stop mode 2 • In the case of "Edge" input External Input and Output PCB Function External input Input signal Command setting Rotary switch Operation Off → On (R.C. enabled) — Input of indoor unit Terminal Stop On → Off (R.C.
  • Page 217: Forced Thermostat Off

     Forced thermostat off External Input and Output External input Input signal Command Rotary switch Off → On Thermostat off External Input and 2, B, C, D Ex IN 1 Output PCB On → Off Normal operation Ex IN 1 Compressor Room temp.
  • Page 218: Error Status

    ¢ Details of control output function  Operation status External Input and Function Output PCB External output Output signal Status setting Rotary switch Off → On Operation 60-00 — Output of indoor unit CN47 On → Off Stop Off → On Operation External Input and —...
  • Page 219: Indoor Unit Fan Operation Status

     Indoor unit fan operation status External Input and Function Output PCB External output Output signal Status setting Rotary switch Off → On Fan run 60-10 — Output of indoor unit CN47 On → Off Fan stop Off → On Fan run External Input and —...
  • Page 220: External Input And Output

    12-2. Mini duct type and Slim duct type Exterior of the indoor unit PCB and the component location differ by the type of the indoor unit as follows. • Mini duct type, and Slim duct types: CN47 (Ext. out) Terminal (Ext. in) Indoor unit PCB External Input...
  • Page 221 ¢ External input With using external input function, some functions on this product can be controlled from an external device. • “Operation/Stop” mode or "Forced stop" mode can be selected with function setting of indoor unit. • A twisted pair cable (22AWG) should be used. Maximum length of cable is 150 m. •...
  • Page 222: Combination Of External Input And Output

    ¢ Combination of external input and output By combining the function setting of the indoor unit, you can select various combinations of func- tions. Combination examples of external input and output are as follows: External input External output Mode Function setting Terminal CN47 60—00...
  • Page 223 ¢ Details of function  Control input function • When function setting is "Operation/Stop" mode 1 Function setting External input Input signal Command Off → On Operation 46—00 Terminal On → Off Stop Input Operation Indoor unit Stop Remote controller NOTES: •...
  • Page 224: Control Output Function

    • When function setting is "Operation/Stop" mode 2 Function setting External input Input signal Command Off → On Operation 46—03 Terminal Stop (Remote controller On → Off disabled) Input Operation Indoor unit Stop (R.C. disabled) Remote controller NOTE: When "Operation/Stop" mode 2 function is used with forming a remote controller group, connect the same equipment to each indoor unit within the group.
  • Page 225: External Heater Output

     Indoor unit fan operation status Function setting External output Output signal Command Low → High Fan run 60—10 CN47 High → Low Fan stop Output signal Condition The indoor unit fan is operating. Low → High The fan is stopped or during cold air prevention. During thermostat off when in dry mode operation.
  • Page 226: 12-3.Wall Mounted Type (Keta, And Keta-B, Kgtb, And 18Kmtb)

    12-3. Wall mounted type (KETA, and KETA-B, KGTB, and 18KMTB) External Input and Output PCB SW301 SW302 Rotary switch CN314 CN313 CN312 CN311 CN310 CN308 To CN6 on Indoor unit PCB Input External input External output Connector Input select signal Operation/Stop CN313/ Edge/Pulse...
  • Page 227: External Input And Output Pcb

    ¢ External input With using external input function, some functions on this product can be controlled from an external device. • “Operation/Stop” mode or "Forced stop" mode can be selected with function setting of indoor unit. • A twisted pair cable should be used. Maximum length of cable is 150 m. •...
  • Page 228 ¢ External output Use an external output cable with appropriate external dimension, depending on the number of ca- bles to be installed.  External Input and Output PCB • A twisted pair cable (22AWG) should be used. Maximum length of cable is 25 m. •...
  • Page 229 ¢ Combination of external input and output By combining the function setting of the indoor unit and rotary switch setting of the External Input and Output PCB, you can select various combinations of functions. Combination examples of external input and output are as follows: External input External Input Function...
  • Page 230  Input signal type External Input and Output PCB: The input signal type can be selected. Signal type (edge or pulse) can be switched by the DIP switch SW302 on the External Input and Output PCB. The width of pulse must be longer than 200 msec.
  • Page 231 ¢ Details of function  Control input function • When function setting is "Operation/Stop" mode 1 – In the case of "Edge" input: Rotary SW on Function External Input and External input Input signal Command setting / Output PCB Off → On Operation External Input and 46—00...
  • Page 232 • When function setting is "Forced stop" mode – In the case of "Edge" input: Rotary SW on Function External Input and External input Input signal Command setting / Output PCB Off → On Forced stop External Input and 46—02 60—00 / 1 CN313 Output PCB...
  • Page 233 • When function setting is "Operation/Stop" mode 2 – In the case of "Edge" input: Rotary SW on Function External Input and External input Input signal Command setting / Output PCB Off → On Operation Stop External Input and 46—03 60—00 / 1 CN313 (Remote...
  • Page 234 • Forced thermostat off function Rotary SW on Function External Input and External input Input signal Command setting / Output PCB Thermostat 60—00 / 2 Off → On External Input and Output 60—09 / B CN313 Normal 60—10 / C On →...
  • Page 235  Control output function • Operation/Stop status Rotary SW on Function Output External Input and External output Command setting / signal Output PCB Off → On Operation External Input and Output 60—00 / 1 CN310 On → Off Stop The output is low when the unit is stopped. Operation Indoor unit Stop...
  • Page 236: 12-4.Wall Mounted Type (07-14Kmtb And Kmcc)

    12-4. Wall mounted type (07-14KMTB and KMCC) With using external input and output functions, this product can be operated inter-connectedly with an external device. Connector Input Output Remarks CNA01 Control input — See external input/output CNB01 — Operation status output settings for details.
  • Page 237 • Circuit diagram example • Contact capacity: DC 24 V or more, 10 Indoor unit mA or more. Communication kit Connected unit control PCB • *: Make the distance from the PCB to Example: Switch Connector the connected unit within 10 m. •...
  • Page 238 • Optional part Part name Model name Exterior External input wire External Connect Kit UTY-XWZXZ5 Communication Kit UTY-TWBXF2 * For operating the external function, the wall mounted type requires the communication kit in addi- tion to the wire (UTY-XWZXZ5). - 230 - 12-4.
  • Page 239: Operation Status Output

    ¢ External output With using external output function, operating status of this product can be transmitted to the exter- nal device, and also, this product can be inter-connected with the external device.  Operation status output Air conditioner operation status signal can be output. •...
  • Page 240: Error Status Output

     Error status output Air conditioner error status signal can be output. • Circuit diagram example: Indoor unit control PCB Communication kit Connected unit Connector DC 24 V Example: Relay unit Example: Display Relay power supply 10 m* Signal Optional parts Locally purchased –...
  • Page 241: 12-5.Wall Mounted Type (Kmce, Kmcf, Kmcg, Kmcg-B, Kmch, Kmch-B, Kete, Kete- B, Ketf, Ketf-B, Kgte, Kgtf, Kgtg, Kgth, And Kmte)

    12-5. Wall mounted type (KMCE, KMCF, KMCG, KMCG-B, KMCH, KMCH-B, KETE, KETE-B, KETF, KETF-B, KGTE, KGTF, KGTG, KGTH, and KMTE) External Input and Output PCB Indoor unit PCB CN47 (Ext. out) CN65 (Ext. in/out PCB) CN46 (Ext. in) SW301 SW302 Rotary switch CN314 CN313...
  • Page 242: Indoor Unit

    ¢ External input With using external input function, some functions on this product can be controlled from an external device. • “Operation/Stop” mode or "Forced stop" mode can be selected with function setting of indoor unit. • A twisted pair cable should be used. Maximum length of cable is 150 m. •...
  • Page 243: External Input And Output Pcb

     External Input and Output PCB The indoor unit Operation/Stop can be set by using the input connector on the PCB. • Input select: Use either one of these types of connectors according to the application. (Both types of connec- tors cannot be used simultaneously.) –...
  • Page 244 ¢ External output Use an external output cable with appropriate external dimension, depending on the number of ca- bles to be installed.  Indoor unit • A twisted pair cable should be used. Maximum length of cable is 25 m. •...
  • Page 245  External Input and Output PCB • A twisted pair cable should be used. Maximum length of cable is 25 m. • Output voltage: High DC 12 V±2 V, Low 0 V. • Permissible current: 50 mA • For details, refer to "Combination of external input and output"...
  • Page 246: Combination Of External Input And Output

    ¢ Combination of external input and output By combining the function setting of the indoor unit and rotary switch setting of the External Input and Output PCB, you can select various combinations of functions. Combination examples of external input and output are as follows: External input Function Rotary...
  • Page 247: Input Signal Type

     Input signal type External Input and Output PCB: The input signal type can be selected. Signal type (edge or pulse) can be switched by the DIP switch SW302 on the External Input and Output PCB. The width of pulse must be longer than 200 msec.
  • Page 248 ¢ Details of function  Control input function • When function setting is “Operation/Stop” mode 1 – In the case of “Edge” input: Function Rotary SW on External External input Input signal Command setting Input and Output PCB Off → On Operation External Input and 46-00...
  • Page 249 • When function setting is “Forced stop” mode – In the case of “Edge” input: Function Rotary SW on External External input Input signal Command setting Input and Output PCB Off → On Forced stop External Input and 46-02 CN313 Output PCB On →...
  • Page 250 • When function setting is “Operation/Stop” mode 2 – In the case of “Edge” input: Function Rotary SW on External External input Input signal Command setting Input and Output PCB Off → On Operation Stop External Input and 46-03 CN313 (Remote Output PCB On →...
  • Page 251 • Forced thermostat off function Rotary SW on Input Function setting / External Input External input Command signal and Output PCB Thermostat 60-00 Off → On External Input and 60-09 CN313 Output PCB Normal On → Off 60-10 operation Input Compressor Room temp.
  • Page 252: Control Output Function

     Control output function • Operation/Stop status Rotary SW on Output Function setting / External Input External output Command signal and Output PCB 60-00 / 1 Off → On Operation Output of indoor unit CN47 60-00 / 2 On → Off Stop 60-00 / 1 Off →...
  • Page 253 • Indoor unit fan operation status Rotary SW on Output Function setting / External Input External output Command signal and Output PCB Off → On Fan run 60-10 / C Output of indoor unit CN47 On → Off Fan stop 60-00 / 2 Off →...
  • Page 254: 12-6.Floor Type

    12-6. Floor type Indoor unit PCB CN 23 CN 21 CN 15 CN 14 P 190 External input External output Connector Input signal Operation/Stop CN14 Forced stop — Edge Forced thermostat off CN15 Operation status Indoor unit Error status CN20/CN21/ —...
  • Page 255 ¢ External output Use an external output cable with appropriate external dimension, depending on the number of ca- bles to be installed.  Indoor unit • A twisted pair cable (22AWG) should be used. Maximum length of cable is 25 m . •...
  • Page 256 ¢ Combination of external input and output By combining the function setting of the indoor unit, you can select various combinations of func- tions. Combination examples of external input and output are as follows: External input Function Mode Indoor unit setting CN14 CN15...
  • Page 257 ¢ Details of function  Control input function • When function setting is "Operation/Stop" mode 1 – In the case of "Edge" input Mode Function setting External input Input signal Command Off → On Operation — CN14 On → Off Stop 46-00 Input of indoor unit...
  • Page 258 • When function setting is "Operation/Stop"mode 2 – In the case of "Edge" input Mode Function setting External input Input signal Command Off → On Operation Stop — CN14 (Remote On → Off controller disabled) 46-03 Input of indoor unit Off →...
  • Page 259  Control output function • Operation/Stop status Output Mode Function setting External output Command signal Low → High Operation 60-00 CN15 High → Low Stop Output of indoor unit Off → On Operation 60-00 CN20 On → Off Stop The output is low when the unit is stopped. Operation Indoor unit Stop...
  • Page 260 • Indoor unit fan operation status Output Mode Function setting External output Command signal Low → High Fan run 60-10 CN15 High → Low Fan stop Output of indoor unit Off → On Fan run 60-00 CN22 On → Off Fan stop Output signal Condition...
  • Page 261 • Design and install external heater appropriately with considering its protection. • Inappropriate designing and installation of external heater may cause a fire by emitted heat from the external heater. • Fujitsu General Ltd. is not responsible for inappropriate designing or installation of external heating device. - 253 - 12-6.
  • Page 262: Auxiliary Heater Control

    • Auxiliary heater control 1 Operation Condition Heater on Heater is on as shown in following diagram of heating temperature. • Heater is off as shown in following diagram of heating temperature. • Other than heating mode Heater off • Error occurred •...
  • Page 263: Group Connection

    13. Group connection NOTE: Group control cannot be used together with WLAN Adapter. Installation procedure for group control system: A number of indoor units can be operated at the same time using a single remote controller. NOTE: When different type of indoor units (such as wall mounted type and cassette type, cassette type and duct type, or other combinations) are connected using group control system, some functions may no longer be available.
  • Page 264 2. Set the remote controller address. (Function setting) • Addresses will be automatically set when initially starting up this unit. In such a case, do not change the remote controller address for the indoor unit, and keep it at the initial setting of “00”.
  • Page 265: Remote Controller

    14. Remote controller 14-1. Wireless remote controller (AR-REW4E, AR-REM4E, AR- REB1E, and AR-REJ1E) ¢ Overview AR-REW4E Signal transmitter MODE button FAN button 10°C HEAT button SWING button ECONOMY button TEMP. button OUTDOOR UNIT SET button LOW NOISE button POWERFUL button WEEKLY button TIMER SETTING button Start/Stop...
  • Page 266: Display Panel

    AR-REM4E Signal SENSOR button transmitter MODE button FAN button 10°C HEAT button SWING button ECONOMY button TEMP. button OUTDOOR UNIT SET button LOW NOISE button POWERFUL button WEEKLY button TIMER SETTING button Start/Stop button ON/OFF button SEND button SLEEP button SELECT button RESET button NEXT button...
  • Page 267 AR-REB1E Signal transmitter MODE button FAN button 10°C HEAT button ECONOMY button SWING button OUTDOOR UNIT SET button LOW NOISE button TEMP. button ON TIMER button POWERFUL button OFF TIMER button Start/Stop button TIMER SELECT button RESET button SLEEP TIMER button CLOCK ADJUST button TIMER CANCEL button NOTE: Functions may differ by type of the indoor unit.
  • Page 268 AR-REJ1E Signal transmitter MODE button FAN button 10°C HEAT button TEMP. SWING button button SET button Economy button ON timer button OFF timer button Start/Stop button REG1U Timer SELECT button RESET button SLEEP timer button TEST RUN button Timer CANCEL button CLOCK ADJUST button NOTE: Functions may differ by type of the indoor unit.
  • Page 269 ¢ Specifications  Controller Unit: mm Top view Front view Side view Size (H × W × D) 205 × 61 × 17 Weight 124 (without batteries)  Holder Unit: mm 48.5 Ø 3.5 (Hole) Hole 26.2 69.3 Front View Side View Bottom View Size (H ×...
  • Page 270: 14-2.Wireless Remote Controller (Ar-Rew3E)

    14-2. Wireless remote controller (AR-REW3E) ¢ Overview Signal SENSOR button transmitter MODE button FAN button 10°C HEAT button SWING button ECONOMY button TEMP. button OUTDOOR UNIT SET button LOW NOISE button POWERFUL button WEEKLY button TIMER SETTING button Start/Stop button ON/OFF button SEND button SLEEP button...
  • Page 271 ¢ Specifications  Controller Unit: mm Top view Front view Side view Size (H × W × D) 205 × 61 × 17 Weight 124 (without batteries)  Holder Unit: mm 48.5 Ø 3.5 (Hole) Hole 26.2 69.3 Front View Side View Bottom View Size (H ×...
  • Page 272: 14-3.Wireless Remote Controller (Ar-Rew2E)

    14-3. Wireless remote controller (AR-REW2E) ¢ Overview Signal transmitter MODE button FAN button 10°C HEAT button SWING button ECONOMY button TEMP. button OUTDOOR UNIT SET button LOW NOISE button POWERFUL button WEEKLY button TIMER SETTING button Start/Stop button ON/OFF button SEND button SLEEP button SELECT button...
  • Page 273 ¢ Specifications  Controller Unit: mm Top view Front view Side view Size (H × W × D) 205 × 61 × 17 Weight 125 (without batteries)  Holder Unit: mm 48.5 Ø 3.5 (Hole) Hole 26.2 69.3 Front View Side View Bottom View Size (H ×...
  • Page 274: 14-4.Wireless Remote Controller (Ar-Rem7E)

    14-4. Wireless remote controller (AR-REM7E) ¢ Overview Signal transmitter MODE button FAN button 10 °C HEAT button SWING button ECONOMY button TEMP. button OUTDOOR UNIT SET button LOW NOISE button POWERFUL button WEEKLY button TIMER SETTING button Start/Stop button ON/OFF button SEND button SLEEP button SELECT button...
  • Page 275 ¢ Specifications  Controller Unit: mm Top view Front view Side view Size (H × W × D) 205 × 61 × 17 Weight 124 (without batteries)  Holder Unit: mm 48.5 Ø 3.5 (Hole) Hole 26.2 69.3 Front View Side View Bottom View Size (H ×...
  • Page 276: 14-5.Wireless Remote Controller (Ar-Rmb1E And Ar-Rmb1E-B)

    14-5. Wireless remote controller (AR-RMB1E and AR-RMB1E-B) ¢ Overview Signal transmitter MODE button FAN button 10°C HEAT button ECONOMY button SWING button OUTDOOR UNIT SET button LOW NOISE button TEMP. button ON TIMER button POWERFUL button OFF TIMER button Start/Stop button TIMER SELECT button RESET button...
  • Page 277 ¢ Specifications  Controller Unit: mm Top view Front view Side view Size (H × W × D) 205 × 61 × 17 Weight 124 (without batteries)  Holder Unit: mm 48.5 Ø 3.5 (Hole) Hole 26.2 69.3 Front View Side View Bottom View Size (H ×...
  • Page 278: Remote Controller (Uty-Lbtgm Or Uty-Lbtgh: Optional Part)

    14-6. Wireless remote controller (UTY-LNTG: Optional part) and IR receiver kit with Wireless remote controller (UTY-LBTGM or UTY-LBTGH: Optional part) ¢ Overview Signal transmitter MODE button FAN button 10°C HEAT button TEMP. SWING button button SET button Economy button ON timer button OFF timer button Start/Stop button...
  • Page 279 ¢ Specifications  Controller Unit: mm Top view Front view Side view Size (H × W × D) 205 × 61 × 17 Weight 124 (without batteries)  Holder Unit: mm 48.5 Ø 3.5 (Hole) Hole 26.2 69.3 Front View Side View Bottom View Size (H ×...
  • Page 280  IR receiver (UTY-LBTGM) Unit: mm 13.6 57.4 13.6 11.5 18.5 Front view Side view Rear view Size (H × W × D) 145 × 90 × 30 Weight  IR receiver (UTY-LBTGH) Unit: mm 23.3 48.6 Ø 5.0 (Hole) Ø...
  • Page 281: 14-7.Wireless Remote Controller (Ar-Rpf4E)

    14-7. Wireless remote controller (AR-RPF4E) ¢ Overview a MODE button • Switches operation mode (AUTO, COOL, DRY, FAN, and HEAT). • Starts/ends the remote controller custom code (max. 4 types) change. b FAN SPEED button • Press the FAN SPEED button while the air conditioner is operating, to control fan speed.
  • Page 282 ¢ Specifications  Controller Unit: mm Top view Front view Side view Size (H × W × D) 162 × 45 × 18 Weight 65.5 (without batteries)  Holder Unit: mm Top view Ø 3.9 (Hole) Hole 26.6 49.3 Front view Side view Size (H ×...
  • Page 283: 14-8.Wired Remote Controller (Uty-Rnngm: Optional Part)

    14-8. Wired remote controller (UTY-RNNGM: Optional part) ¢ Overview a START/STOP button Starts and stops operation. b SET TEMP. button Selects the setting temperature. c MODE button Selects the operating mode (AUTO , HEAT ,FAN COOL , and DRY d FAN button Selects the fan speed AUTO ,QUIET , LOW...
  • Page 284: System Diagram

    ¢ System diagram 1 remote controller: 2 remote controllers: Indoor unit Indoor unit A, B, C: Remote controller cable A ≤ 500 m;B + C ≤ 500 m Primary Secondary Remote controllers Remote controller ¢ Electrical wiring 1 remote controller: 2 remote controllers: Indoor unit Indoor unit...
  • Page 285: Wiring Specifications

    ¢ Specifications Dimensions and other specifications on the wired remote controller are as follows. Unit: mm Front view Side view Size (H × W × D) 120 × 120 × 18 Weight Cable length (accessory) Power  Wiring specifications Cable size Wire type Remarks Remote controller cable...
  • Page 286  When connecting to Communication Kit (for KM models in Wall mounted type) When connecting the remote controller to optional Communication Kit, follow the procedures men- tioned below. Modify the remote controller cable as follows: • Use a tool to cut off the terminal on the end of the remote controller cable and then remove the insulation from the cut end of the cable as shown in following figure.
  • Page 287: 14-9.Wired Remote Controller (Uty-Rvrg : Optional Part)

    14-9. Wired Remote Controller (UTY-RVRG : Optional part) • Easy finger touch operation with LCD panel. • Screen with anti-fingerprint coating • Various information display (Room temp., Operation mode, Set temp. Fan speed, Timer) • Control up to 16 indoor units •...
  • Page 288 Temperature setting screen a Page indicator Shows the oder of pages and displayed page. b Operation On/Off button Tap to start operation or stop the air conditioner. c Bluetooth icon Displays when Bluetooth is enabled. d Information area The displayed contents differ depending on the screen and settings.
  • Page 289: System Diagrams

    ¢ System diagrams • Multiple remote control Up to 2 remote controllers can be used to operate the indoor units. I.U. I.U. – Remote controller • A: UTY-RVRG • B: Other than UTY-RVRG (2-wire type only) – Remote controller cable •...
  • Page 290 • Maximum connectable number of remote controller (2-wire type) Maximum connectable number of remote controller (2-wire type) is limited by cable size and maxi- mum cable length. When using only remote controller other than UTY-RVRG Cable size (S) Total cable length (L) L ≤...
  • Page 291: Group Control

    ¢ Electrical wiring 1 remote controller: 2 remote controllers: Indoor unit Indoor unit When there is When there is a functional a functional grounding grounding Remote controller Remote controller Remote controller Group control: Indoor units When there is a functional grounding Remote controller - 283 - 14-9.
  • Page 292: Installation Space

    ¢ Dimensions Unit: mm Hole: 8.2 × 20.5 Hole: 9 × 4.5 33.5 Hole: 6 × 4.5 Hole: 12.5 × 4.5 ¢ Installation space • This product cannot be installed in a wall. • Even when you install a remote controller to one of a switch box and the surface of a wall, secure the space shown in following figure.
  • Page 293 ¢ Installation For details of installation, refer to the INSTALLATION MANUAL for this product. • Connector removal Open the front case and remove the connector of the remote controller cable from the connector of the PCB on the front case (back side). Fron case (back side) Rear case Connector...
  • Page 294 • Rear case installation – When attaching to switch box: Seal the wiring hole of the remote controller cable with putty. Trap (remote controller cable) Connector Putty Self-tapping screw Rear case Trap – When attaching to the wall directly: Wall Seal the wiring hole of the remote controller cable with putty.
  • Page 295 • Remote controller cable connection – Fasten the outside covering of the connection cable with the cable tie. Cable tie – Connect the connector of the remote controller cable to the connector of the PCB on the front case (back side). Clamp Rear case Front case...
  • Page 296 ¢ Specifications Input voltage DC 12 Power consumption Max. 1.0 Display 4-inch TFT LCD (480 × 480 pixels) with touch screen Usage temperature range °C 0 to 40 Usage humidity range 20 to 90 (no condensation) Storage temperature range °C -10 to 60 Storage humidity range 20 to 90 (no condensation)
  • Page 297: On/Off Button

    14-10. Wired remote controller (UTY-RLRG: Optional part) ¢ Overview a LED lamp (Operation indicator) Lights while the indoor unit is operating. Blinks when an error occurred. b FAN button Each time the button is pressed, fan speed switches as follows: Auto High Quiet...
  • Page 298: System Diagram

    ¢ System diagram 1 remote controller: 2 remote controllers: Indoor unit Indoor unit A, B, C: Remote controller cable A ≤ 500 m;B + C ≤ 500 m Primary Secondary Remote controllers Remote controller ¢ Electrical wiring 1 remote controller: 2 remote controllers: Indoor unit Indoor unit...
  • Page 299 ¢ Specifications Dimensions and other specifications on the wired remote controller are as follows. Unit: mm Hole: 9 × 4.5 Hole: 12.5 × 4.5 Hole: 6 × 4.5 Front view Side view Rear view Size (H × W × D) 120 ×...
  • Page 300 NOTES: • The detailed shape and the layout of the terminal block and the PCB vary depending on the indoor unit type. • Operation may fail if it is connected to the outdoor unit or the terminal block for power sup- ply.
  • Page 301: 14-11.Wired Remote Controller (Uty-Rvngm: Optional Part)

    14-11. Wired remote controller (UTY-RVNGM: Optional part) ¢ Overview a Display panel (with backlight) b Screen switch button (Left) c Menu button d Cancel button e Cursor button f Screen switch button (Right) g Power indicator h On/off button i Enter button - 293 - 14-11.
  • Page 302: Controller Combination

    ¢ System diagram 1 remote controller: 2 remote controllers: Indoor unit Indoor unit A, B, C: Remote controller cable A ≤ 500 m;B + C ≤ 500 m Primary Secondary Remote controllers Remote controller ¢ Electrical wiring 1 remote controller: 2 remote controllers: Indoor unit Indoor unit...
  • Page 303 ¢ Specifications Unit: mm 21.3 Front view Side view Size (H × W × D) 120 × 120 × 21.3 Weight  Wiring specifications Cable size Wire type Remarks Remote controller cable Polar 3 core Use sheathed PVC cable. 0.33 mm - 295 - 14-11.
  • Page 304: Installation Procedures

    ¢ Installation (Remote control main unit) Installation space: Unit : mm or more or more or more 220 or more* NOTE: Secure enough space where a flat-blade screwdriver to remove the case can be inserted. Installation procedures: 1. Process the remote controller cable. Unit : mm 1.
  • Page 305 3. Attach the remote controller. • When attaching to switch box: a. Seal the wiring hole of the remote controller cable. b. Put a remote controller cable through the hole of the rear case. c. Fix the rear case by securing it with attached screws (2 places). •...
  • Page 306: Terminal Screw

    4. Connect the cable to the terminals on the front case. Fix the cable together with the sheath with the cable tie. Cut off the excess cable tie. Tightening torque Terminal screw 0.8 to 1.2 N•m 1. 12V (Red) 2. Signal (White) 3.
  • Page 307 5. Attach the front case. • Insert after adjusting upper part of front case. • When insert the front case, do not pinch the cable. Front case Click! Good Prohibited Prohibited Prohibited CAUTION Insert the upper case firmly. If improperly attached, it will cause the upper case to fall off. ¢...
  • Page 308  When connecting to Communication Kit (for KM models in Wall mounted type) When connecting the remote controller to optional Communication Kit, follow the procedures men- tioned below. Modify the remote controller cable as follows: • Use a tool to cut off the terminal on the end of the remote controller cable and then remove the insulation from the cut end of the cable as shown in following figure.
  • Page 309: 14-12.Wired Remote Controller (Uty-Rnrgz*: Optional Part)

    14-12. Wired remote controller (UTY-RNRGZ*: Optional part) ¢ Overview a Remote temperature sensor (inside) b On/off button Operable only while displaying the “Monitor mode” screen. c LED lamp (operation indicator) d Touch panel display e Set temperature Operating temperature can be set. f Remote controller group name g Mode Operation mode can be set.
  • Page 310 ¢ System diagram 1 remote controller: 2 remote controllers: Indoor unit Indoor unit A, B, C: Remote controller cable A ≤ 500 m;B + C ≤ 500 m Primary Secondary Remote controllers Remote controller ¢ Electrical wiring 1 remote controller: 2 remote controllers: Indoor unit Indoor unit...
  • Page 311 ¢ Specifications Dimensions and other specifications on the wired remote controller are as follows. Unit: mm 20.4 Model name UTY-RNRGZ* Display 3.8-inch FSTN LCD (255 × 160 dots) with touch panel Dimensions (H × W × D) 120 × 120 × 20.4 Weight Input voltage DC 12...
  • Page 312 Terminal block Remote controller cable (Non-polar) NOTES: • The detailed shape and the layout of the terminal block and the PCB vary depending on the indoor unit type. • Operation may fail if it is connected to the outdoor unit or the terminal block for power sup- ply.
  • Page 313: 14-13.Wired Remote Controller (Uty-Rcrgz1: Optional Part)

    14-13. Wired remote controller (UTY-RCRGZ1: Optional part) ¢ Overview a Display panel b MODE button c Menu button buttons (Set temperature buttons) e FAN button f On/off button g Wireless remote controller signal receiving section - 305 - 14-13. Wired remote controller (UTY-RCRGZ1: Optional part) 14.
  • Page 314 ¢ System diagrams • Single remote control I.U. Remote controller cable A ≤ 500 m ¢ Electrical wiring Indoor unit Remote controller - 306 - 14-13. Wired remote controller (UTY-RCRGZ1: Optional part) 14. Remote controller...
  • Page 315 ¢ Specifications Unit: mm Hole × 2 (for M4 screws) Size (H × W × D) 86 × 86 × 32 Weight  Wiring specifications Cable size Wire type Remarks Remote controller 0.33 to 1.25 mm Non polar 2-core Use sheathed twist pair cable.* cable (22 to 16 AWG) *: Use shielded cable (locally purchased) in accordance with the regional cable standard.
  • Page 316 • Pattern B 1. Use a tool to cut off the terminal on the end of the remote controller cable, and then remove the insulation from the cut end of the cable as shown below. 20 mm Remote controller cable (Non-polar) 2.
  • Page 317: 14-14.Simple Remote Controller (Uty-Rsngm: Optional Part)

    14-14. Simple remote controller (UTY-RSNGM: Optional part) ¢ Overview a START/STOP button Starts and stops operation. b Display backlight button Lights during operation. c Operation lamp Lights during operation. d FAN button Selects the fan speed (AUTO ,HIGH , MED , and QUIET ).
  • Page 318 ¢ System diagram 1 remote controller: 2 remote controllers: Indoor unit Indoor unit A, B, C: Remote controller cable A ≤ 500 m;B + C ≤ 500 m Primary Secondary Remote controllers Remote controller ¢ Electrical wiring 1 remote controller: 2 remote controllers: Indoor unit Indoor unit...
  • Page 319 ¢ Specifications Dimensions and other specifications on the wired remote controller are as follows. Unit: mm hole x 2 hole x 2 Front View Side View Rear View Size (H × W × D) 120 × 75 × 14 Weight Cable length (accessory) Power ...
  • Page 320  When connecting to Communication Kit (for KM models in Wall mounted type) When connecting the remote controller to optional Communication Kit, follow the procedures men- tioned below. Modify the remote controller cable as follows: • Use a tool to cut off the terminal on the end of the remote controller cable and then remove the insulation from the cut end of the cable as shown in following figure.
  • Page 321: 14-15.Simple Remote Controller (Uty-Rsrg And Uty-Rhrg: Optional Parts)

    14-15. Simple remote controller (UTY-RSRG and UTY-RHRG: Optional parts) ¢ Overview a LED lamp Lights during operation. b Louver button Adjusts the airflow direction. c START/STOP button Starts and stops operation. d FAN control button Switches the fan speed as follows: Auto High Quiet...
  • Page 322 ¢ System diagram 1 remote controller: 2 remote controllers: Indoor unit Indoor unit A, B, C: Remote controller cable A ≤ 500 m;B + C ≤ 500 m Primary Secondary Remote controllers Remote controller ¢ Electrical wiring 1 remote controller: 2 remote controllers: Indoor unit Indoor unit...
  • Page 323 ¢ Specifications Dimensions and other specifications on the wired remote controller are as follows. Unit: mm 30.0 30.0 Hole: 9 × 4.5 23.0 Hole: 6 × 4.5 Hole: 12.5 × 4.5 Front View Side View Rear View Size (H × W × D) 120 ×...
  • Page 324 NOTES: • The detailed shape and the layout of the terminal block and the PCB vary depending on the indoor unit type. • Operation may fail if it is connected to the outdoor unit or the terminal block for power sup- ply.
  • Page 325: Function Settings

    15. Function settings To adjust the functions of this product according to the installation environment, various types of function settings are available. NOTE: Incorrect settings can cause a product malfunction. 15-1. Compact cassette, Mini duct, Slim duct types indoor unit (setting by DIP switch) By using some components on the PCB, you can change the function settings.
  • Page 326: Dip Switch Setting

    ¢ DIP switch setting • SW100: Remote controller address setting When operating a number of indoor units by using a wired remote controller, DIP switch set- ting for assigning unit number to each indoor unit is required. The slide switches are normally set to make the unit number 00. Remote Switch number controller...
  • Page 327: 15-2.Medium Static Pressure Duct Type

    15-2. Medium static pressure duct type By using some components on the PCB, you can change the function settings. Related components on the PCB and the applicable settings Component Setting content Drainage function setting Setting change prohibited DIP switch101 Fan delay setting Setting change prohibited ...
  • Page 328: 15-3.Indoor Unit (Setting By Wireless Remote Controller)

    15-3. Indoor unit (setting by wireless remote controller) CAUTION This setting changes the function settings used to control the indoor unit according to the installa- tion conditions. Incorrect settings can cause a product malfunction. • After the power is turned on, perform the “Function setting” according to the installation conditions using the remote controller.
  • Page 329 ¢ AR-REM4E (for Wall mounted type KGTB), AR-REW3E (for Wall mounted type KGTE, KGTF, KGTG, and KGTH), AR-REW4E (for Wall mounted type KETA[-B], KETE[-B], and KETF[-B]), AR- REW2E (for Wall mounted type KMTB and KMTE), and AR- REM7E (for Floor type) ...
  • Page 330  Function setting procedure Connect the power supply of the outdoor unit. To enter the function setting mode, while holding down the POWERFUL and TEMP. button, press the RESET button. POWERFUL TEMP. ( RESET Function setting mode display Select the function number by pressing the or the buttons.
  • Page 331 Press the MODE button once to transmit the function mode information. Press the button once to transmit the function setting information. 2 short beeps will be emitted from the indoor unit when the signal is received correctly. If wrong code is set, no beep sound will be emitted.
  • Page 332  Resetting the power after setting up all indoor units Important: • If the reset is not performed, function cannot be read correctly. • After all the functions have been set, the circuit breaker needs to be switched off for at least 2 minutes.
  • Page 333  Remote controller custom code setting Custom code setting of wireless remote controller needs to be same as the setting of the indoor unit. When you change the custom code setting of the wireless remote controller, do as follows: Press the START/STOP button until only the clock is displayed on the display. Press the MODE button for at least 5 seconds to display the current custom code (initially set to Press the TEMP.
  • Page 334 ¢ AR-REB1E (for Wall mounted type KMTB and KMCC) and AR- RMB1E(-B) (for Wall mounted type KMCE, KMCF, KMCG, KMCG-B, KMCH, and KMCH-B)  Button name and function During address setting mode, indoor unit reject the any operation command from remote con- troller.
  • Page 335  Function setting procedure Connect the power supply of the outdoor unit. To enter the function setting mode, while holding down the POWERFUL and SET TEMP. buttons, press the RESET button. POWERFUL SET TEMP. ( RESET Function setting mode display Select the function number by pressing the or the buttons.
  • Page 336 Press the MODE button once to transmit the function mode information. 2 short beeps Press the button once to transmit the function setting information. 2 short beeps will be emitted from the indoor unit when the signal is received correctly. If wrong code is set, no beep sound will be emitted.
  • Page 337  Resetting the power after setting up all indoor units Important: • If the reset is not performed, function cannot be read correctly. • After all the functions have been set, the circuit breaker needs to be switched off for at least 2 minutes.
  • Page 338  Remote controller custom code setting Custom code setting of wireless remote controller needs to be same as the setting of the indoor unit. When you change the custom code setting of the wireless remote controller, do as follows: Press the START/STOP button until only the clock is displayed on the display. Press the MODE button for at least 5 seconds to display the current custom code (initially set to Press the SET TEMP.
  • Page 339 ¢ UTY-LNTG (for Compact cassette type) or AR-REJ1E (included in UTY-LBTGM for Duct type, UTY-LBTGH for Ceiling type)  Button name and function During address setting mode, indoor unit reject the any operation command from remote con- troller. Function number Refer to Function details.
  • Page 340  Function setting procedure Connect the power supply of the outdoor unit. To enter the function setting mode, while holding down the ECONOMY and TEMP. buttons, press the RESET button. ECONOMY TEMP. ( RESET Function setting mode display - 332 - 15-3.
  • Page 341 Select the function number by pressing the or the buttons. Each time the 10°C HEAT button is pressed, it switches between the right digit and the left digit. Change digit Change digit Proceed to the setting number by pressing the ECONOMY button. (To return to the function number selection, press the ECONOMY button again.) Select the function number by pressing the or the...
  • Page 342 Press the button once to transmit the function setting information. 1 short beep will be emit- ted from the indoor unit or the IR receiver when the signal is received correctly. If wrong code is set, no beep sound will be emitted. 1 short beep NOTE: Press button within 30 seconds after pressing MODE button.
  • Page 343  Resetting the power after setting up all indoor units Important: • If the reset is not performed, function cannot be read correctly. • After all the functions have been set, the circuit breaker needs to be switched off for at least 2 minutes.
  • Page 344  Remote controller custom code setting Custom code setting of wireless remote controller needs to be same as the setting of the indoor unit. When you change the custom code setting of the wireless remote controller, do as follows: Press the START/STOP button until only the clock is displayed on the display. Press the MODE button for at least 5 seconds to display the current custom code (initially set to Press the TEMP.
  • Page 345 ¢ AR-RPF4E (for Wall mounted type KNCA and KNCH) The function number and the associated setting value are displayed on the LCD of the remote con- troller. Follow the instructions written in the local setup procedure supplied with the remote controller, and select appropriate setting according to the installation environment.
  • Page 346 STEP 2: Selecting the function number and setting value 1. Press the TEMP./SELECT ( ) buttons to select the function Function number number. To switch between the left and right digits, press the MODE button. 2. Press the FAN SPEED button to proceed the setting value. To re- turn the function number selection, press the FAN SPEED button again.
  • Page 347  Custom code setting on AR-RPF4E To interconnect the air conditioner and the wireless remote controller, assignment of the custom code for the wireless remote controller is required. NOTE: Air conditioner cannot receive a signal if the air conditioner has not been set for the custom code.
  • Page 348: 15-4.Indoor Unit (Setting By Wired Remote Controller)

    15-4. Indoor unit (setting by wired remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit malfunction. • After the power is turned on, perform the “Function setting” according to the installation conditions using the remote controller.
  • Page 349 ¢ UTY-RNNGM  Button name and function During address setting mode, indoor unit reject the any operation command from remote controller. Function number Refer to Function details Remote controller address Setting number Refer to Function details Λ SET TEMP. “V” and “ ”...
  • Page 350 Confirm the setting by pressing the TIMER SET button. The data will be transferred to the indoor unit. Not good Good ● Data is not set up on the indoor unit Data is correctly set up on the indoor unit correctly (-- is displayed.) (Flashing display changes to illuminated display.) ●...
  • Page 351: Setting Procedure By Using Wired Remote Controller

    ¢ UTY-RLRG  Setting procedure by using wired remote controller The function number and the associated setting value are displayed on the LCD of the remote con- troller. Follow the instructions written in the local setup procedure supplied with the remote controller, and select appropriate setting according to the installation environment.
  • Page 352 Pressing the "+" or "-" button, to select the function number. Then press the "ENTER" button. Function number Pressing the "+" or "-" button, to select the setting number. Then press the "ENTER" button. Setting number Example: Function number 30 Setting number 01 Error Good...
  • Page 353 ¢ UTY-RVNGM  Function setting procedure Connect the power supply of the outdoor unit. Switch to the function setting mode. When [Menu button] is pressed twice while “Monitor” screen is displayed, it switches to the “Submenu” screen. If [Menu button] is pressed while the “Submenu” screen is displayed, the display returns to the “Monitor”...
  • Page 354 Select the [Function No.] with pressing the [Cursor button (Left/Right)], and select the Function No. to be set with pressing the [Cursor button (Up/Down)]. Function setting Mo 10:00AM R.C. Function Setting address Cancel: Version Error history Select the [Setting No.] with pressing the [Cursor button (Left/Right)], and select the Setting No. to be set with pressing the [Cursor button (Up/Down)].
  • Page 355 When [Cancel button] is pressed twice while “Function setting” screen is displayed, it switches to the “Submenu” screen. Function setting Mo 10:00AM R.C. Function Setting Submenu Mo 10:00AM address Date and time Screen Cancel: Filter sign Version Error history R.C. sensor control Room temp.
  • Page 356 ¢ UTY-RNRGZ*  Setting procedure by using wired remote controller The function number and the associated setting value are displayed on the LCD of the remote con- troller. Follow the instructions written in the local setup procedure supplied with the remote controller, and select appropriate setting according to the installation environment.
  • Page 357 “Function No.” screen is displayed. Set the “Function No.” with Function No. Cancel When the “OK” is touched, the display returns to the “Function Setting” screen. Touch the “Function No.” on the “Function Setting” screen. Function Setting Address [002–01] Function No. [30] Setting No.
  • Page 358 Touch the “Yes” of the verification screen. Function Setting Function setting will be performed. OK? In case of “ERROR” In case of “OK” Function Setting Function Setting Address [002–01] Address [002–01] Function No. [30] Function No. [30] Setting No. [01] Setting No.
  • Page 359 ¢ UTY-RVRG  Function setting procedure Tap the menu as shown below. Enter the Admin password. Enter the Installer password. Tap “Address” on the Function Setting screen. Pull-down window of indoor unit address is displayed. Select the address of the indoor unit whose function number is to be set.
  • Page 360 Pull-down window of Function No. is displayed. Set the Function No to be set. Tap “Setting No.” on the Function Setting screen. Pull-down window of “Setting No.” is displayed. Set the Setting No. Tap “Set” on the verification screen. to return to the Initial Setting screen. - 352 - 15-4.
  • Page 361: 15-5.Indoor Unit (Setting By Simple Remote Controller)

    15-5. Indoor unit (setting by simple remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit malfunction. • After the power is turned on, perform the “Function setting” according to the installation conditions using the remote controller.
  • Page 362 ¢ UTY-RSNGM  Button name and function During address setting mode, indoor unit reject the any operation command from remote controller. Function number Setting number Refer to Function details Refer to Function details Remote controller address START/STOP button Transmits function setting FAN button SET TEMP.
  • Page 363 Select the setting number by pressing the SET TEMP. or SET TEMP. button. The setting number indicator flashes during setting number selection. Setting number Example) Function number : 30, Setting number : 01 Confirm the setting by pressing the TIMER SET button. The data will be transferred to the indoor unit.
  • Page 364  Resetting the power after setting up function of all indoor units NOTES: • If the reset is not performed, function cannot be read correctly. • After all the functions have been set, the circuit breaker needs to be switched off for at least 2 minutes.
  • Page 365 ¢ UTY-RSRG/UTY-RHRG  Setting procedure by using wired remote controller The function number and the associated setting value are displayed on the LCD of the remote con- troller. Follow the instructions written in the local setup procedure supplied with the remote controller, and select appropriate setting according to the installation environment.
  • Page 366 Select the item number to be set with the SET TEMP. or SET TEMP. button, and press button to switch to the setting screen. Select the “13” in Menu 2-F1 settings. Then, press the button. Select the 2-wire remote controller address with the SET TEMP. or SET TEMP.
  • Page 367 Press the button to return to the 2-wire remote controller address selection screen of step 9. If setting has been completed, press the FAN button to return to the Menu 2-F1 item selec- tion screen.  Setting up each indoor unit Repeat the procedure from step 1 to 6, and set up the indoor units requiring function setting.
  • Page 368: Function Setting List

    15-6. Function details ¢ Contents of function setting Each function setting listed in this section is adjustable in accordance with the installation environ- ment. NOTE: Setting will not be changed if invalid numbers or setting values are selected.  Function setting list Medium Function Compact...
  • Page 369 Wall mounted Functio Functions KMCG KMCH KETA n no. KMCC KMCE KMCF (-B) (-B) (-B) Remote controller ● — — — — ● address setting Filter sign ● ● ● ● ● ● Ceiling height — — — — — —...
  • Page 370 Wall mounted Functio Functions KETE KETF n no. KGTB KGTE KGTF KGTG (-B) (-B) Remote controller — — ● — — — address setting Filter sign ● ● ● ● ● ● Ceiling height — — — — — — Outlet directions —...
  • Page 371 Wall mounted Functio Functions n no. KGTH KNCA KNCH KMTB KMTE Remote controller — — — ● — address setting Filter sign ● ● ● ● ● Ceiling height — — — — — Outlet directions — — — — —...
  • Page 372: Filter Sign

    1) Remote controller address setting (for Wall-mounted type only) NOTES: • Because this setting is normally done automatically when 2-wire-type wired remote controller is installed, setting is unnecessary. • This setting is configurable only by wireless remote controller, but not configurable by Polar 3- wired remote controller.
  • Page 373 3) Ceiling height (for Compact cassette type and Ceiling type only) Select the appropriate ceiling height according to the place of installation. Function number Setting value Setting description Factory setting Standard ♦ High ceiling For the specific height for each setting value, refer to “Installation space” in Chapter 4. "Dimensions"...
  • Page 374 5) Static pressure (for Mini duct type, Slim duct type, and Medium static pressure duct type) Select the appropriate static pressure according to the installation conditions. For mini duct type: Function number Setting value Setting description Factory setting 0 Pa 10 Pa 20 Pa 30 Pa...
  • Page 375: Factory Setting

    6) Horizontal louver direction switching for dew condensation prevention (for Ceiling type only) Automatically switches the position of the horizontal louver if the airflow direction is set at lower than the dew condensation limit position in cooling or drying operation. Select suitable adjustment position according to the customer’s preference.
  • Page 376: Auto Restart

    8) Room temperature control for wired remote controller sensor (for other than Floor type and KN models in Wall-mounted type) Depending on the installed environment, correction of the wire remote temperature sensor may be required. Select the appropriate control setting according to the installed environment. To change this setting, set Function 42 to Both “01”.
  • Page 377 11) Remote controller custom code (Only for wireless remote controller) The indoor unit custom code can be changed. Select the appropriate custom code. Function number Setting value Setting description Factory setting ♦ 12) External input control “Operation/Stop” mode or “Forced stop” mode can be selected. Function number Setting value Setting description...
  • Page 378 15) Switching functions for external output terminal (For other than 18KMTB, KETA and KN models in Wall-mounted type) Functions of the external output terminal can be switched. For details, refer to “External input and output”. Function number Setting value Setting description Factory setting Operation status ♦...
  • Page 379: 15-7.Wired Remote Controller (Uty-Rnngm)

    15-7. Wired remote controller (UTY-RNNGM) Prohibited Dual remote controller setting Prohibited DIP switch 1 °F/°C switch Prohibited Memory backup setting * Do not use DIP switch 2. ¢ Switch location Front case (back side) DIP switch 2 DIP switch 1 ¢...
  • Page 380  SW6: Memory backup setting Set to “ON” to use batteries for the memory backup. When batteries are not used, all of settings stored in memory will be deleted if there is a power failure. Memory backup Factory setting Disable ♦...
  • Page 381: 15-8.Wired Remote Controller (Uty-Rvngm)

    15-8. Wired remote controller (UTY-RVNGM) Memory backup setting DIP switch 1 Dual remote controller setting ¢ Switch location ¢ DIP switch setting  SW1: Memory backup setting Set to “ON” to use batteries for the memory backup. When batteries are not used, all of settings stored in memory will be deleted if there is a power failure.
  • Page 382: 15-9.Wired Remote Controller (Uty-Rlrg)

    15-9. Wired remote controller (UTY-RLRG) DIP switch Memory backup setting ¢ Switch location Front case (back side) Set the DIP switch to ON ¢ Dip switch setting  SW1: Memory backup setting Set to “ON” to use batteries for the memory backup. When batteries are not used, all of settings stored in memory will be deleted if there is a power failure.
  • Page 383: 15-11.Simple Remote Controller (Uty-Rsngm)

    15-11. Simple remote controller (UTY-RSNGM) Prohibited Dual remote controller setting °F/°C switch DIP switch Prohibited Prohibited Prohibited ¢ Switch location DIP Switch ¢ DIP switch setting  SW2: Dual remote controller setting Set the remote controller SW2 according to the following table. Primary unit Secondary unit Number of remote controller...
  • Page 384: Accessories

    16. Accessories 16-1. Compact cassette type ¢ Models: AUXG07–18KVLA Part name Exterior Part name Exterior Operation manual Drain hose insulation Operation manual Hose band (CD-ROM) Coupler heat insulation Installation manual (large) Coupler heat insulation Template (Carton top) (small) M10 nut A Cable tie (with flange) M10 nut B...
  • Page 385: 16-2.Mini Duct Type

    16-2. Mini duct type ¢ Models: ARXG07–14KSLAP Part name Exterior Part name Exterior Operation manual Drain hose Operation manual Hose band (CD-ROM) Installation manual Drain hose insulation B Installation template Washer (Carton top) Coupler heat insulation Cable tie (large) (large) Coupler heat insulation Cable tie (medium) (small)
  • Page 386 ¢ Model: ARXG18KSLAP Part name Exterior Part name Exterior Operation manual Drain hose Operation manual Hose band (CD-ROM) Installation manual Drain hose insulation B Installation template Washer (Carton top) Coupler heat insulation Cable tie (large) (large) Coupler heat insulation Cable tie (medium) (small) Insulation Filter (large)
  • Page 387: 16-3.Slim Duct Type

    16-3. Slim duct type ¢ Models: ARXG07–18KLLAP Part name Exterior Part name Exterior Operation manual Cable tie (Large) Installation manual Cable tie (Small) Installation template Drain hose Washer Hose band Coupler heat insulation Drain hose insulation B (Large) Coupler heat insulation Remote controller (Small) Filter (Small)
  • Page 388: 16-4.Medium Static Pressure Duct Type

    16-4. Medium static pressure duct type ¢ Models: ARXH12–18KMTAP Part name Exterior Part name Exterior Operation manual Cable tie (large) Operation manual Cable tie (medium) (CD-ROM) Installation manual Cable tie (small) Washer Drain hose insulation Coupler heat insulation Drain hose (large) Coupler heat insulation Hose band...
  • Page 389: 16-5.Wall Mounted Type

    16-5. Wall mounted type ¢ Models: ASHG07–14KMCE and ASHG07–14KMCF Part name Exterior Part name Exterior Operation manual Cloth tape Operation manual Self-tapping screw (CD-ROM) (large) Self-tapping screw Installation manual (small) Remote controller Wall hook bracket Battery Filter holder Remote controller Air cleaning filters holder - 381 -...
  • Page 390 ¢ Models: ASHH07–14KMCG, ASHH07–14KMCG-B, and ASHH07– 14KGTG Part name Exterior Part name Exterior Operation manual Cloth tape Self-tapping screw Installation manual (large) Self-tapping screw Remote controller (small) Battery Wall hook bracket Remote controller Filter holder holder Installation spacer Air cleaning filters Operation manual (CD-ROM) - 382 -...
  • Page 391 ¢ Models: ASHH07–14KMCH, ASHH07–14KMCH-B, and ASHH07– 14KGTH Part name Exterior Part name Exterior Operation manual Cloth tape Self-tapping screw Installation manual (large) Self-tapping screw Remote controller (small) Battery Wall hook bracket Remote controller Filter holder holder Installation spacer Air cleaning filters - 383 - 16-5.
  • Page 392 ¢ Models: ASHG07–14KETA, ASHG07–14KETA-B, ASHG07– 14KETE, ASHG07–14KETE-B, ASHG07–14KETF, and ASHG07– 14KETF-B Part name Exterior Part name Exterior Operation manual Cloth tape Operation manual Self-tapping screw (CD-ROM) (large) Self-tapping screw Installation manual (small) Remote controller Wall hook bracket Battery Filter holder Remote controller Air cleaning filters holder...
  • Page 393 ¢ Models: ASHG07–14KGTB, ASHG07–14KMTB, and ASHG07– 14KMCC Part name Exterior Part name Exterior Operation manual Cloth tape Operation manual Self-tapping screw (CD-ROM) (large) Self-tapping screw Installation manual (small) Remote controller Wall hook bracket Battery Filter holder Remote controller Air cleaning filters holder - 385 - 16-5.
  • Page 394 ¢ Models: ASHG07–14KGTE and ASHG07–14KGTF Part name Exterior Part name Exterior Operation manual Cloth tape Operation manual Self-tapping screw (CD-ROM) (large) Self-tapping screw Installation manual (small) Remote controller Wall hook bracket Battery Filter holder Remote controller Air cleaning filters holder ¢...
  • Page 395 ¢ Models: ASHH05–12KNCH Part name Exterior Part name Exterior Self-tapping screw Operation manual (Large) Self-tapping screw Installation manual (Small) Remote controller Wall hook bracket Remote controller Battery holder Installation spacer Cloth tape - 387 - 16-5. Wall mounted type 16. Accessories...
  • Page 396 ¢ Model: ASHG18KMTB Part name Exterior Part name Exterior Self-tapping screw Operation manual (large) Self-tapping screw Installation manual (small) Remote controller Battery Remote controller Filter holder holder Cloth tape Air cleaning filters Wall hook bracket - 388 - 16-5. Wall mounted type 16.
  • Page 397 ¢ Model: ASHG18KMTE Part name Exterior Part name Exterior Operation manual Cloth tape Operation manual Self-tapping screw (CD-ROM) (large) Self-tapping screw Installation manual (small) Remote controller Wall hook bracket Remote controller Filter holder holder Battery Air cleaning filters - 389 - 16-5.
  • Page 398: 16-6.Ceiling Type

    16-6. Ceiling type ¢ Model: ABHG18KRTA Part name Exterior Part name Exterior Operation manual Insulation Operation manual Drain hose (CD-ROM) Installation manual Hose band Template Cable tie (large) M10 nut A Cable tie (small) (with flange) M10 nut B Remote controller cable (with spring lock hole cap washer)
  • Page 399: 16-7.Floor Type

    16-7. Floor type ¢ Models: AGHG09–14KVCA Part name Exterior Part name Exterior Operation manual (CD- Operation manual ROM) Installation manual Cloth tape Self-tapping screws Wall hook bracket (large) Self-tapping screws Remote controller (small) Battery Air cleaning filters Remote controller holder - 391 - 16-7.
  • Page 400: Optional Parts

    17. Optional parts 17-1. Controllers ¢ Lineup Type Indoor unit type Wireless Remote Controller AR-REM4E AR-REM7E AR-REB1E AR-REW2E AR-REW3E Compact cassette — — — — — Mini duct — — — — — Slim duct — — — — — Medium static pressure duct —...
  • Page 401: Wireless Remote Controller

    Type Indoor unit type Wireless Remote Controller AR-REW4E AR-RMB1E(-B) AR-RPF4E UTY-LNTG Compact cassette — — — ◌ Mini duct — — — — Slim duct — — — — Medium static pressure duct — — — — Floor — — —...
  • Page 402: Wired Remote Controller

    Type Indoor unit type Wired Remote Controller UTY-RNNGM UTY-RVNGM UTY-RVRG UTY-RLRG Compact cassette ◌ ◌ ◌ ◌ Mini duct ◌ ◌ ◌ ◌ Slim duct ◌ ◌ ◌ ◌ Medium static pressure duct — — ◌ ◌ Floor — — ◌...
  • Page 403 Type IR Receiver Kit with Wireless Indoor unit type Wired Remote Controller Remote Controller UTY-RNRGZ* UTY-RCRGZ1 UTY-LBTGM UTY-LBTGH Compact cassette ◌ ◌ — — Mini duct ◌ ◌ ◌ — Slim duct ◌ ◌ ◌ — Medium static pressure duct ◌...
  • Page 404: Simple Remote Controller

    Type Indoor unit type Simple Remote Controller UTY-RSNGM UTY-RSRG UTY-RHRG Compact cassette ◌ ◌ ◌ Mini duct ◌ ◌ ◌ Slim duct ◌ ◌ ◌ Medium static pressure duct — ◌ ◌ Floor — ◌ ◌ Ceiling — ◌ ◌ KMCC —...
  • Page 405 ¢ Parts Exterior Part name Model name Summary Remote controller that provides the functions you need in a sleek design Wired Remote that uniquely transforms itself to blend Controller UTY-RVRG with any interior. (Touch Panel) Wire type: Non-polar 2-wire Easy finger touch operation with LCD Wired Remote panel.
  • Page 406 Exterior Part name Model name Summary Compact remote controller concentrates on the basic functions such as Start/Stop, fan control, and Simple Remote temperature setting. UTY-RHRG Controller Wire type: Non-polar 2-wire Compact remote controller concentrates on the basic functions such as Start/Stop, fan control, temperature setting, and operation Simple Remote UTY-RSNGM...
  • Page 407: 17-2.Cassette Grille

    17-2. Cassette grille ¢ Lineup Indoor unit type Model Compact cassette UTG-UFGF-W ¢ Part Exterior Part name Model name Summary This cassette grille can be installed Cassette Grille UTG-UFGF-W appropriately on the grid type ceiling common in the office. - 399 - 17-2.
  • Page 408: 17-3.Others

    17-3. Others ¢ Lineup Type Air Outlet Shutter Insulation Kit for Fresh Air Intake Half Concealed Indoor unit type Plate High Humidity UTR-YDZB UTZ-KXGC UTZ-VXAA UTR-STA Compact cassette ◌ ◌ ◌ — Mini duct — — — — Slim duct —...
  • Page 409: Auto Louver Grille Kit

    Type Auto Louver External Switch Remote Sensor Unit Grille Kit Controller Indoor unit type UTD-GXTA-W UTY-XSZX UTY-XSZXZ* UTY-TERX UTD-GXTB-W Compact cassette — — — ◌ Mini duct ◌ ◌ ◌ ◌ Slim duct ◌ ◌ ◌ ◌ Medium static pressure duct —...
  • Page 410: External Connect Kit

    Type External Input and Output Indoor unit type External Connect Kit UTY-XWZX UTY-XWZXZ5 UTY-XWZXZG UTY-XCSXZ2 UTY-XCSX Compact cassette — — ◌ — ◌ Mini duct — — ◌ — — Slim duct — — ◌ — — Medium static pressure duct —...
  • Page 411: Network Converter

    Type Modbus Indoor unit type KNX Convertor Network Converter Converter UTY-VKSX UTY-VTGX UTY-VTGXV UTY-VMSX Compact cassette ◌ ◌ ◌ ◌ Mini duct ◌ ◌ ◌ ◌ Slim duct ◌ ◌ ◌ ◌ Medium static pressure duct ◌ ◌ ◌ ◌ Floor ◌...
  • Page 412 Type Indoor unit type Communication Kit UTY-TWBXF2 UTY-TWRXZ2 UTY-TWRXZ3 Compact cassette — — — Mini duct — — — Slim duct — — — Medium static pressure duct — — — Floor — — ◌ Ceiling — — — KMCC ◌...
  • Page 413 Type Indoor unit type WLAN Adapter* UTY-TFSXW1 UTY-TFSXF2 UTY-TFSXZ1 UTY-TFSXH3 UTY-TFSXJ3 Compact cassette — — ◌ — — Mini duct — — ◌ — — Slim duct — — ◌ — — Medium static pressure duct — — ◌ — ◌...
  • Page 414: Air Cleaning Filter

    Type Indoor unit type Air Cleaning Filter UTR-FA16-5 UTD-HFNC Compact cassette — — Mini duct — — Slim duct — — Medium static pressure duct — ◌ Floor — — Ceiling — — KMCC ◌ — KMCE ◌ — KMCF ◌...
  • Page 415 Type Indoor unit type Long-life Filter External Input and Output PCB Box UTD-LFDC UTZ-GXDA UTZ-GXEA Compact cassette — — — Mini duct — — — Slim duct — — — Medium static pressure duct ◌ ◌ — Floor — — —...
  • Page 416 ¢ Parts Exterior Part name Model name Summary Thermo-sensor for sensing the Remote Sensor temperature of arbitrary place in the UTY-XSZX Unit room. Thermo-sensor for sensing the Remote Sensor temperature of arbitrary place in the UTY-XSZXZ* Unit room. Width: 683 mm Auto Louver UTD-GXTA-W Grille Kit...
  • Page 417 Exterior Part name Model name Summary Insulation Install when the under-roof condition is Insulation Kit for expected to be the humidity of over UTZ-KXGC High Humidity 80% and the temperature of over 30 °C. Half Concealed Used for the indoor unit installing of UTR-STA half concealed.
  • Page 418 Exterior Part name Model name Summary Remotely manage an air conditioning system using mobile devices such as smartphones and tablets. For connection indoor unit with UART UTY-TFSXZ1 interface. WLAN Adapter UTY-TFSXJ3 Appropriate application for each region is required to use this option. For details, contact FGL sales company.
  • Page 419: Indoor Unit Installation Precautions

    18. Indoor unit installation precautions NOTE: The information listed below are general precautions. Some models also include items that do not apply. 18-1. Places where prohibited for use • Places where there is a danger of combustible gas leakage. • Places where sulfur gas, chlorine gas, acid, alkali, or other matter which effects equipment is gen- erated.
  • Page 420 Condition Contents Countermeasures (Reference) When inside the When the indoor unit is installed where the inside of the 1. Add heat insulating material to ceiling is high ceiling is 30 °C RH80% or greater, the dew point the outside of the indoor unit temperature temperature of the outer perimeter may become higher cabinet.
  • Page 421 Condition which requires addition of outside heat insulation Relative humidity 80 % Dry bulb temperature 30 °C Figure 18-1 Moist air curve Slit of heat insulating material Heat insulation reinforcement material Flare connection facing upward (locally purchased) To indoor unit Covered gas pipe (heat insulation...
  • Page 422 - 414 - 18-2. Points to remember when installing 18. Indoor unit installation precautions...
  • Page 423: Part 2. Outdoor Unit (3 Units Type)

    Part 2. OUTDOOR UNIT (3 UNITS TYPE) MULTI-SPLIT TYPE: AOHG18KBTA3 AOHG24KBTA3...
  • Page 424: Specifications

    1. Specifications Type Inverter heat pump Model name AOHG18KBTA3 AOHG24KBTA3 Power source 230 V 50 Hz Available voltage range 198—264V Wall mounted Wall mounted Standard combination of indoor unit ASHG07KMCC ASHG07KMCC ×3 ASHG09KMCC ×2 Rated Btu/h 18,400 23,200 Cooling 1.8—7 1.8—8.5 Min.—Max.
  • Page 425 Specifications for ErP Lot10 Model name AOHG18KBTA3 AOHG24KBTA3 Cooling Energy efficiency class Heating (Average) Cooling 5.4 (35 °C) 6.8 (35 °C) Pdesign Heating (Average) 5.0 (-10 °C) 6.0 (-10 °C) SEER Cooling 8.60 8.50 kWh/kWh SCOP Heating (Average) 4.70 4.60 Annual energy consumption kWh/a QHE (Average)
  • Page 426: Dimensions

    2. Dimensions 2-1. Models: AOHG18KBTA3 and AOHG24KBTA3 Unit: mm 4-M10 hole Pitch of bolts for installation Top view Side view Front view Side view Airflow Drain port Ø42 Bottom view Side view (Valve part) - 418 - 2-1. Models: AOHG18KBTA3 and AOHG24KBTA3 2.
  • Page 427: Installation Space

    3. Installation space 3-1. Models: AOHG18KBTA3 and AOHG24KBTA3 ¢ Space requirement Provide sufficient installation space for product safety. CAUTION Keep the space shown in the installation examples. If the installation is not performed accordingly, it could cause a short circuit and result in a lack of operating performance.
  • Page 428: Multiple Outdoor Unit Installation

     Multiple outdoor unit installation • Provide at least 250 mm of space between the outdoor units if multiple units are installed. • When routing the piping from the side of an outdoor unit, provide space for piping. • No more than 3 units must be installed side by side. When 4 units or more are arranged in a line, provide the space as shown in the following ex- ample “When an obstruction in the upper space:”.
  • Page 429: Outdoor Units Installation In Multi-Row

     Outdoor units installation in multi-row Unit: mm Single parallel unit arrangement Multiple parallel unit arrangement 100 or more 200 or more 1,000 or more 2,000 or more 200 or more 400 or more 500 or more 1,000 or more 200 or more 250 or more 1,000 or more...
  • Page 430: Refrigerant Circuit

    4. Refrigerant circuit 4-1. Models: AOHG18KBTA3 and AOHG24KBTA3 Pressure switch CONDENSER - 422 - 4-1. Models: AOHG18KBTA3 and AOHG24KBTA3 4. Refrigerant circuit...
  • Page 431: Wiring Diagram

    5. Wiring diagram 5-1. Models: AOHG18KBTA3 and AOHG24KBTA3 - 423 - 5-1. Models: AOHG18KBTA3 and AOHG24KBTA3 5. Wiring diagram...
  • Page 432: Capacity Table

    6. Capacity table 6-1. Combinations ¢ Model: AOHG18KBTA3  Cooling Indoor unit combination (Wall-mounted KG/KM type only) Rated capacity for each in- Total capacity Combination of indoor unit Input power (kW) Seasonal data door unit (kW) (kW) Room Room (W/W) Pdesign SEER Energy effi-...
  • Page 433 NOTES: • 5: 5,000 Btu/h, 7: 7,000 Btu/h, 9: 9,000 Btu/h, 12: 12,000 Btu/h, 14: 14,000 Btu/h • The above is the value for connecting with wall-mounted type indoor unit. • 2 or more indoor units should be connected. • Cooling: Indoor temperature of 27 °CDB/19 °CWB and outdoor temperature of 35 °CDB. •...
  • Page 434  Heating Indoor unit combination (Wall-mounted KG/KM type only) Rated capacity for each in- Total capacity Combination of indoor unit Input power (kW) Seasonal data door unit (kBtu/h) (kBtu/h) Room Room (W/W) Pdesign SCOP Energy effi- Total Min. Rated Max. Min.
  • Page 435 ¢ Model: AOHG24KBTA3  Cooling Indoor unit combination (Wall-mounted KG/KM type only) Rated capacity for each in- Total capacity Combination of indoor unit Input power (kW) Seasonal data door unit (kW) (kW) Room Room (W/W) Pdesign SEER Energy effi- Total Min.
  • Page 436 Rated capacity for each in- Total capacity Combination of indoor unit Input power (kW) Seasonal data door unit (kW) (kW) Room Room (W/W) Pdesign SEER Energy effi- Min. Rated Max. Min. Rated Max. Total (kW) (kWh/kWh) ciency class 2.40 2.40 3.00 2.00 7.80...
  • Page 437  Heating Indoor unit combination (Wall-mounted KG/KM type only) Rated capacity for each in- Total capacity Combination of indoor unit Input power (kW) Seasonal data door unit (kW) (kW) Room Room (W/W) Pdesign SCOP Energy effi- Total Min. Rated Max. Min.
  • Page 438 Rated capacity for each in- Total capacity Combination of indoor unit Input power (kW) Seasonal data door unit (kW) (kW) Room Room (W/W) Pdesign SCOP Energy effi- Min. Rated Max. Min. Rated Max. Total (kW) (kWh/kWh) ciency class 2.00 2.57 3.43 2.00 8.00...
  • Page 439: Cooling Capacity

    6-2. Cooling capacity NOTE: Values mentioned in the table are calculated based on the maximum capacity. ¢ Model: AOHG18KBTA3 Indoor temperature Indoor unit connect- Outdoor temperature 18.0 °CDB 21.0 °CDB 23.0 °CDB 27.0 °CDB 29.0 °CDB 32.0 °CDB ing capacity 12.0 °CWB 15.0 °CWB 16.0 °CWB...
  • Page 440 Indoor temperature Indoor unit connect- Outdoor temperature 18.0 °CDB 21.0 °CDB 23.0 °CDB 27.0 °CDB 29.0 °CDB 32.0 °CDB ing capacity 12.0 °CWB 15.0 °CWB 16.0 °CWB 19.0 °CWB 21.0 °CWB 23.0 °CWB kBtu/h °CDB -10.0 5.49 0.88 6.20 0.89 6.54 0.90 7.00...
  • Page 441 Indoor temperature Indoor unit connect- Outdoor temperature 18.0 °CDB 21.0 °CDB 23.0 °CDB 27.0 °CDB 29.0 °CDB 32.0 °CDB ing capacity 12.0 °CWB 15.0 °CWB 16.0 °CWB 19.0 °CWB 21.0 °CWB 23.0 °CWB kBtu/h °CDB -10.0 3.92 0.63 4.43 0.64 4.67 0.65 5.00...
  • Page 442: Compact Cassette Type

     Compact cassette type Model: AUXG07KVLA Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.32 2.22 1.51 2.34 1.74 2.50 1.95 2.67 2.13...
  • Page 443: Mini Duct Type

     Mini duct type Model: ARXG07KSLAP Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.36 2.22 1.55 2.34 1.78 2.50 2.00 2.67 2.19...
  • Page 444: Slim Duct Type

     Slim duct type Model: ARXG07KLLAP Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.36 2.22 1.55 2.34 1.78 2.50 2.00 2.67 2.19...
  • Page 445  Medium static pressure duct type Model: ARXH12KMTAP Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 3.37 2.27 3.81 2.59 4.02 2.99 4.30 3.35...
  • Page 446: Wall Mounted Type

     Wall mounted type Model: ASHG07KMTB Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78...
  • Page 447 Model: ASHG07KMCC Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 448 Model: ASHG07KMCE Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 449 Model: ASHG07KMCF Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 450 Model: ASHH07KMCG, ASHH07KMCG-B Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0...
  • Page 451 Model: ASHH07KMCH, ASHH07KMCH-B Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0...
  • Page 452 Model: ASHG07KETA, ASHG07KETA-B Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0...
  • Page 453 Model: ASHG07KETE, ASHG07KETE-B Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0...
  • Page 454 Model: ASHG07KETF, ASHG07KETF-B Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0...
  • Page 455 Model: ASHG07KGTB Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 456 Model: ASHG07KGTE Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 457 Model: ASHG07KGTF Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 458 Model: ASHH07KGTG Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 459 Model: ASHH07KGTH Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 460 Model: ASHH05KNCA Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.41 0.79 1.59 0.90 1.68 1.04 1.80 1.17 1.92 1.28 1.98 1.47 -5.0 1.41...
  • Page 461 Model: ASHH05KNCH Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.41 0.79 1.59 0.90 1.68 1.04 1.80 1.17 1.92 1.28 1.98 1.47 -5.0 1.41...
  • Page 462: Floor Type

     Floor type Model: AGHG09KVCA Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 2.51 1.71 2.84 1.95 2.99 2.25 3.20 2.53 3.42 2.76 3.53...
  • Page 463 ¢ Model: AOHG24KBTA3 Indoor temperature Indoor unit connect- Outdoor temperature 18.0 °CDB 21.0 °CDB 23.0 °CDB 27.0 °CDB 29.0 °CDB 32.0 °CDB ing capacity 12.0 °CWB 15.0 °CWB 16.0 °CWB 19.0 °CWB 21.0 °CWB 23.0 °CWB kBtu/h °CDB -10.0 6.66 1.23 7.53 1.25...
  • Page 464 Indoor temperature Indoor unit connect- Outdoor temperature 18.0 °CDB 21.0 °CDB 23.0 °CDB 27.0 °CDB 29.0 °CDB 32.0 °CDB ing capacity 12.0 °CWB 15.0 °CWB 16.0 °CWB 19.0 °CWB 21.0 °CWB 23.0 °CWB kBtu/h °CDB -10.0 6.66 1.23 7.53 1.25 7.94 1.26 8.50...
  • Page 465 Indoor temperature Indoor unit connect- Outdoor temperature 18.0 °CDB 21.0 °CDB 23.0 °CDB 27.0 °CDB 29.0 °CDB 32.0 °CDB ing capacity 12.0 °CWB 15.0 °CWB 16.0 °CWB 19.0 °CWB 21.0 °CWB 23.0 °CWB kBtu/h °CDB -10.0 5.88 1.04 6.65 1.06 7.01 1.07 7.50...
  • Page 466 NOTES: • TC: Total Capacity (kW), IP: Input Power (kW) • Values mentioned in the table are based on the following conditions: – Power source of specifications: 230 V – Pipe length: 5 m, Height difference: 0 m (Outdoor unit—Indoor unit) •...
  • Page 467: Compact Cassette Type

     Compact cassette type Model: AUXG07KVLA Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.32 2.22 1.51 2.34 1.74 2.50 1.95 2.67 2.13...
  • Page 468 Model: AUXG18KVLA Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 4.80 2.91 5.42 3.31 5.72 3.81 6.12 4.28 6.54 4.69 6.74 5.37 -5.0 4.80...
  • Page 469: Mini Duct Type

     Mini duct type Model: ARXG07KSLAP Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.36 2.22 1.55 2.34 1.78 2.50 2.00 2.67 2.19...
  • Page 470 Model: ARXG18KSLAP Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74 5.52 -5.0 4.80...
  • Page 471: Slim Duct Type

     Slim duct type Model: ARXG07KLLAP Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.36 2.22 1.55 2.34 1.78 2.50 2.00 2.67 2.19...
  • Page 472 Model: ARXG18KLLAP Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74 5.52 -5.0 4.80...
  • Page 473  Medium static pressure duct type Model: ARXH12KMTAP Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 3.37 2.27 3.81 2.59 4.02 2.99 4.30 3.35...
  • Page 474: Wall Mounted Type

     Wall mounted type Model: ASHG07KMTB Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78...
  • Page 475 Model: ASHG07KMCC Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 476 Model: ASHG07KMCE Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 477 Model: ASHG07KMCF Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 478 Model: ASHH07KMCG, ASHH07KMCG-B Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0...
  • Page 479 Model: ASHH07KMCH, ASHH07KMCH-B Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0...
  • Page 480 Model: ASHG07KETA, ASHG07KETA-B Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0...
  • Page 481 Model: ASHG07KETE, ASHG07KETE-B Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0...
  • Page 482 Model: ASHG07KETF, ASHG07KETF-B Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0...
  • Page 483 Model: ASHG07KGTB Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 484 Model: ASHG07KGTE Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 485 Model: ASHG07KGTF Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 486 Model: ASHH07KGTG Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 487 Model: ASHH07KGTH Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.96 1.10 2.22 1.26 2.34 1.45 2.50 1.63 2.67 1.78 2.76 2.04 -5.0 1.96...
  • Page 488 Model: ASHH05KNCA Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.41 0.79 1.59 0.90 1.68 1.04 1.80 1.17 1.92 1.28 1.98 1.47 -5.0 1.41...
  • Page 489 Model: ASHH05KNCH Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 1.41 0.79 1.59 0.90 1.68 1.04 1.80 1.17 1.92 1.28 1.98 1.47 -5.0 1.41...
  • Page 490 Model: ASHG18KMTB Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 4.80 3.24 5.42 3.69 5.72 4.25 6.12 4.77 6.54 5.22 6.74 5.98 -5.0 4.80...
  • Page 491: Ceiling Type

     Ceiling type Model: ABHG18KRTA Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 4.80 2.99 5.42 3.41 5.72 3.92 6.12 4.41 6.54 4.82 6.74...
  • Page 492: Floor Type

     Floor type Model: AGHG09KVCA Indoor temperature (°CDB / °CWB) Outdoor temperature 18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0 (°CDB) -10.0 2.51 1.71 2.84 1.95 2.99 2.25 3.20 2.53 3.42 2.76 3.53...
  • Page 493: Heating Capacity

    6-3. Heating capacity NOTE: Values mentioned in the table are calculated based on the maximum capacity. ¢ Model: AOHG18KBTA3 Indoor temperature Indoor unit connecting Outdoor temperature capacity 16.0 °CDB 18.0 °CDB 20.0 °CDB 22.0 °CDB 24.0 °CDB kBtu/h °CDB °CWB -15.0 -16.0 6.41...
  • Page 494 Indoor temperature Indoor unit connecting Outdoor temperature capacity 16.0 °CDB 18.0 °CDB 20.0 °CDB 22.0 °CDB 24.0 °CDB kBtu/h °CDB °CWB -15.0 -16.0 6.41 3.03 6.25 3.09 6.10 3.15 5.95 3.21 5.80 3.28 -10.0 -11.0 7.23 3.21 7.06 3.27 6.88 3.34 6.71 3.41...
  • Page 495 NOTES: • TC: Total Capacity (kW), IP: Input Power (kW) • Values mentioned in the table are based on the following conditions: – Power source of specifications: 230 V – Pipe length: 5 m, Height difference: 0 m (Outdoor unit—Indoor unit) •...
  • Page 496: Compact Cassette Type

     Compact cassette type Model: AUXG07KVLA Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80...
  • Page 497: Mini Duct Type

     Mini duct type Model: ARXG07KSLAP Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80...
  • Page 498: Slim Duct Type

     Slim duct type Model: ARXG07KLLAP Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80...
  • Page 499  Medium static pressure duct type Model: ARXH12KMTAP Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 3.83 3.74 3.65 3.56 3.47 -10.0 -11.0 4.33 4.23 4.13 4.02 3.92 -5.0 -7.0 4.64 4.53 4.42 4.31 4.20 -2.0 5.04...
  • Page 500: Wall Mounted Type

     Wall mounted type Model: ASHG07KMTB Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80...
  • Page 501 Model: ASHG07KMCC Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80 2.73 2.66 2.94 2.87...
  • Page 502 Model: ASHG07KMCE Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80 2.73 2.66 2.94 2.87...
  • Page 503 Model: ASHG07KMCF Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80 2.73 2.66 2.94 2.87...
  • Page 504 Model: ASHH07KMCG, ASHH07KMCG-B Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.54 1.50 1.46 1.43 1.39 -10.0 -11.0 1.91 1.87 1.82 1.78 1.73 -5.0 -7.0 2.27 2.22 2.17 2.11 2.06 -2.0 2.68 2.61 2.55 2.48 2.42 2.94...
  • Page 505 Model: ASHH07KMCH, ASHH07KMCH-B Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.54 1.50 1.46 1.43 1.39 -10.0 -11.0 1.91 1.87 1.82 1.78 1.73 -5.0 -7.0 2.27 2.22 2.17 2.11 2.06 -2.0 2.68 2.61 2.55 2.48 2.42 2.94...
  • Page 506 Model: ASHG07KETA, ASHG07KETA-B Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80 2.73 2.66 2.94...
  • Page 507 Model: ASHG07KETE, ASHG07KETE-B Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80 2.73 2.66 2.94...
  • Page 508 Model: ASHG07KETF, ASHG07KETF-B Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80 2.73 2.66 2.94...
  • Page 509 Model: ASHG07KGTB Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80 2.73 2.66 2.94 2.87...
  • Page 510 Model: ASHG07KGTE Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80 2.73 2.66 2.94 2.87...
  • Page 511 Model: ASHG07KGTF Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.23 2.18 2.13 2.07 2.02 -10.0 -11.0 2.53 2.47 2.41 2.35 2.29 -5.0 -7.0 2.70 2.64 2.58 2.51 2.45 -2.0 2.94 2.87 2.80 2.73 2.66 2.94 2.87...
  • Page 512 Model: ASHH07KGTG Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.54 1.50 1.46 1.43 1.39 -10.0 -11.0 1.91 1.87 1.82 1.78 1.73 -5.0 -7.0 2.27 2.22 2.17 2.11 2.06 -2.0 2.68 2.61 2.55 2.48 2.42 2.94 2.87...
  • Page 513 Model: ASHH07KGTH Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.54 1.50 1.46 1.43 1.39 -10.0 -11.0 1.91 1.87 1.82 1.78 1.73 -5.0 -7.0 2.27 2.22 2.17 2.11 2.06 -2.0 2.68 2.61 2.55 2.48 2.42 2.94 2.87...
  • Page 514 Model: ASHH05KNCA Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.19 1.16 1.13 1.10 1.07 -10.0 -11.0 1.37 1.33 1.30 1.27 1.24 -5.0 -7.0 1.55 1.51 1.47 1.44 1.40 -2.0 1.97 1.92 1.88 1.83 1.78 2.21 2.15...
  • Page 515 Model: ASHH05KNCH Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.19 1.16 1.13 1.10 1.07 -10.0 -11.0 1.37 1.33 1.30 1.27 1.24 -5.0 -7.0 1.55 1.51 1.47 1.44 1.40 -2.0 1.97 1.92 1.88 1.83 1.78 2.21 2.15...
  • Page 516: Floor Type

     Floor type Model: AGHG09KVCA Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.87 2.80 2.74 2.67 2.60 -10.0 -11.0 3.25 3.17 3.10 3.02 2.94 -5.0 -7.0 3.48 3.39 3.31 3.23 3.15 -2.0 3.78 3.69 3.60 3.51...
  • Page 517 ¢ Model: AOHG24KBTA3 Indoor temperature Indoor unit connecting Outdoor temperature capacity 16.0 °CDB 18.0 °CDB 20.0 °CDB 22.0 °CDB 24.0 °CDB kBtu/h °CDB °CWB -15.0 -16.0 6.47 3.09 6.32 3.16 6.16 3.22 6.01 3.29 5.85 3.35 -10.0 -11.0 7.30 3.28 7.13 3.35 6.95...
  • Page 518 Indoor temperature Indoor unit connecting Outdoor temperature capacity 16.0 °CDB 18.0 °CDB 20.0 °CDB 22.0 °CDB 24.0 °CDB kBtu/h °CDB °CWB -15.0 -16.0 6.47 3.09 6.32 3.16 6.16 3.22 6.01 3.29 5.85 3.35 -10.0 -11.0 7.30 3.28 7.13 3.35 6.95 3.41 6.78 3.48...
  • Page 519 Indoor temperature Indoor unit connecting Outdoor temperature capacity 16.0 °CDB 18.0 °CDB 20.0 °CDB 22.0 °CDB 24.0 °CDB kBtu/h °CDB °CWB -15.0 -16.0 5.06 2.31 4.94 2.36 4.82 2.41 4.70 2.46 4.58 2.50 -10.0 -11.0 5.71 2.45 5.58 2.50 5.44 2.55 5.31 2.60...
  • Page 520  Compact cassette type Model: AUXG07KVLA Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58...
  • Page 521 Model: AUXG18KVLA Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 4.66 4.55 4.44 4.32 4.21 -10.0 -11.0 5.28 5.16 5.03 4.91 4.78 -5.0 -7.0 5.63 5.50 5.36 5.23 5.09 -2.0 6.39 6.24 6.09 5.94 5.79 6.95 6.79...
  • Page 522  Mini duct type Model: ARXG07KSLAP Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58...
  • Page 523 Model: ARXG18KSLAP Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 4.66 4.55 4.44 4.32 4.21 -10.0 -11.0 5.28 5.16 5.03 4.91 4.78 -5.0 -7.0 5.63 5.50 5.36 5.23 5.09 -2.0 6.39 6.24 6.09 5.94 5.79 6.95 6.79...
  • Page 524  Slim duct type Model: ARXG07KLLAP Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58...
  • Page 525 Model: ARXG18KLLAP Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 4.66 4.55 4.44 4.32 4.21 -10.0 -11.0 5.28 5.16 5.03 4.91 4.78 -5.0 -7.0 5.63 5.50 5.36 5.23 5.09 -2.0 6.39 6.24 6.09 5.94 5.79 6.95 6.79...
  • Page 526  Medium static pressure duct type Model: ARXH12KMTAP Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 3.38 3.30 3.22 3.14 3.06 -10.0 -11.0 3.83 3.74 3.65 3.56 3.47 -5.0 -7.0 4.08 3.99 3.89 3.79 3.69 -2.0 4.64...
  • Page 527  Wall mounted type Model: ASHG07KMTB Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58...
  • Page 528 Model: ASHG07KMCC Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58 2.51 2.45 2.94 2.87...
  • Page 529 Model: ASHG07KMCE Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58 2.51 2.45 2.94 2.87...
  • Page 530 Model: ASHG07KMCF Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58 2.51 2.45 2.94 2.87...
  • Page 531 Model: ASHH07KMCG, ASHH07KMCG-B Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.54 1.50 1.46 1.43 1.39 -10.0 -11.0 1.91 1.87 1.82 1.78 1.73 -5.0 -7.0 2.27 2.22 2.17 2.11 2.06 -2.0 2.68 2.61 2.55 2.48 2.42 2.94...
  • Page 532 Model: ASHH07KMCH, ASHH07KMCH-B Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.54 1.50 1.46 1.43 1.39 -10.0 -11.0 1.91 1.87 1.82 1.78 1.73 -5.0 -7.0 2.27 2.22 2.17 2.11 2.06 -2.0 2.68 2.61 2.55 2.48 2.42 2.94...
  • Page 533 Model: ASHG07KETA, ASHG07KETA-B Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58 2.51 2.45 2.94...
  • Page 534 Model: ASHG07KETE, ASHG07KETE-B Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58 2.51 2.45 2.94...
  • Page 535 Model: ASHG07KETF, ASHG07KETF-B Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58 2.51 2.45 2.94...
  • Page 536 Model: ASHG07KGTB Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58 2.51 2.45 2.94 2.87...
  • Page 537 Model: ASHG07KGTE Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58 2.51 2.45 2.94 2.87...
  • Page 538 Model: ASHG07KGTF Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.97 1.92 1.88 1.83 1.78 -10.0 -11.0 2.23 2.18 2.13 2.07 2.02 -5.0 -7.0 2.38 2.32 2.27 2.21 2.15 -2.0 2.70 2.64 2.58 2.51 2.45 2.94 2.87...
  • Page 539 Model: ASHH07KGTG Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.54 1.50 1.46 1.43 1.39 -10.0 -11.0 1.91 1.87 1.82 1.78 1.73 -5.0 -7.0 2.27 2.22 2.17 2.11 2.06 -2.0 2.68 2.61 2.55 2.48 2.42 2.94 2.87...
  • Page 540 Model: ASHH07KGTH Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.54 1.50 1.46 1.43 1.39 -10.0 -11.0 1.91 1.87 1.82 1.78 1.73 -5.0 -7.0 2.27 2.22 2.17 2.11 2.06 -2.0 2.68 2.61 2.55 2.48 2.42 2.94 2.87...
  • Page 541 Model: ASHH05KNCA Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.48 1.44 1.41 1.37 1.34 -10.0 -11.0 1.68 1.64 1.60 1.56 1.52 -5.0 -7.0 1.79 1.74 1.70 1.66 1.62 -2.0 2.03 1.98 1.93 1.88 1.84 2.21 2.15...
  • Page 542 Model: ASHH05KNCH Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 1.48 1.44 1.41 1.37 1.34 -10.0 -11.0 1.68 1.64 1.60 1.56 1.52 -5.0 -7.0 1.79 1.74 1.70 1.66 1.62 -2.0 2.03 1.98 1.93 1.88 1.84 2.21 2.15...
  • Page 543 Model: ASHG18KMTB Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 4.66 4.55 4.44 4.32 4.21 -10.0 -11.0 5.28 5.16 5.03 4.91 4.78 -5.0 -7.0 5.63 5.50 5.36 5.23 5.09 -2.0 6.39 6.24 6.09 5.94 5.79 6.95 6.79...
  • Page 544  Ceiling type Model: ABHG18KRTA Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 4.66 4.55 4.44 4.32 4.21 -10.0 -11.0 5.28 5.16 5.03 4.91 4.78 -5.0 -7.0 5.63 5.50 5.36 5.23 5.09 -2.0 6.39 6.24 6.09 5.94...
  • Page 545  Floor type Model: AGHG09KVCA Indoor temperature (°CDB) Outdoor temperature 16.0 18.0 20.0 22.0 24.0 (°CDB) (°CWB) -15.0 -16.0 2.53 2.47 2.41 2.35 2.29 -10.0 -11.0 2.87 2.80 2.74 2.67 2.60 -5.0 -7.0 3.06 2.99 2.92 2.84 2.77 -2.0 3.48 3.39 3.31 3.23...
  • Page 546: Capacity Compensation Rate For Pipe Length And Height Difference

    7. Capacity compensation rate for pipe length and height difference Height difference H Indoor unit is higher than outdoor unit Indoor unit is lower than outdoor unit Outdoor unit Indoor unit Outdoor unit Indoor unit Connection pipe Connection pipe 7-1. Models: AOHG18KBTA3 and AOHG24KBTA3 NOTE: Values mentioned in the table are calculated based on the maximum capacity.
  • Page 547 ¢ Indoor unit: 9,000 Btu/h Pipe length Cooling — — — 0.956 0.942 0.928 Indoor unit is higher than — — 0.977 0.963 0.950 0.936 outdoor unit * — 0.992 0.985 0.971 0.957 0.943 1.003 0.996 0.989 0.975 0.961 0.947 1.007 1.000 0.993...
  • Page 548 ¢ Indoor unit: 14,000 Btu/h Pipe length Cooling — — — 0.969 0.962 0.953 Indoor unit is higher than — — 0.982 0.977 0.970 0.961 outdoor unit * — 0.992 0.990 0.985 0.977 0.968 0.998 0.996 0.994 0.989 0.981 0.972 1.002 1.000 0.998...
  • Page 549: Additional Charge Calculation

    8. Additional charge calculation 8-1. Model: AOHG18KBTA3 Refrigerant type Refrigerant amount 1,800 Refrigerant charge Total pipe length 30 or less 50 (Max.) 20 g/m Additional charge amount 8-2. Model: AOHG24KBTA3 Refrigerant type Refrigerant amount 1,800 Refrigerant charge Total pipe length 30 or less 50 (Max.) 20 g/m...
  • Page 550: Airflow

    9. Airflow 9-1. Model: AOHG18KBTA3  Cooling 2,220 1,307  Heating 2,160 1,271 9-2. Model: AOHG24KBTA3  Cooling 2,270 1,336  Heating 2,730 1,607 - 542 - 9-1. Model: AOHG18KBTA3 9. Airflow...
  • Page 551: Operation Noise (Sound Pressure)

    10. Operation noise (sound pressure) 10-1. Noise level curve ¢ Model: AOHG18KBTA3  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000...
  • Page 552: 10-2.Sound Level Check Point

    10-2. Sound level check point Rear Microphone Microphone Airflow Side view Rear view NOTE: Detailed shape of the actual outdoor unit might be slightly different from the one illustrated above. - 544 - 10-2. Sound level check point 10. Operation noise (sound pressure)
  • Page 553: Electrical Characteristics

    11. Electrical characteristics Model name AOHG18KBTA3 AOHG24KBTA3 Voltage 230 ~ Power supply Frequency 12.0 14.5 Maximum operating current * Starting current Main fuse (Circuit breaker) current Power cable Wiring spec. * Connection Cross-sectional area cable * Limited wiring length : Maximum operating current is the total current of the indoor unit and the outdoor unit. : Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005.
  • Page 554: Safety Devices

    12. Safety devices Model Type of Protection form protection AOHG18KBTA3 AOHG24KBTA3 250 V, 5 A 250 V, 5 A Current fuse Circuit protection 250 V, 20 A 250 V, 25 A (Main PCB) 250 V, 3.15 A 250 V, 3.15 A 125 ±10°C 125 ±10°C Activate...
  • Page 555: Function Settings

    13. Function settings 13-1. Setting methods WARNING Never touch electrical components such as the terminal blocks or reactor except the switch on the display board. It may cause a serious accident such as electric shock. CAUTION • Once refrigerant charging is completed, be sure to open the valve prior to performing the local settings.
  • Page 556: Setting Method

    ¢ Setting method Various settings can be adjusted by changing DIP switches and push switches on the PCB of the outdoor unit. LED display part POWER MONITOR ERROR /MODE ( GRN ) ( RED ) TEST RUN / SET 1 SET 2 CHECK PUMP DOWN...
  • Page 557: Description Of Display

    ¢ Description of display LED lamp Function or operation method • Turns on when the power supply is ON (Including when error occurs). (1) POWER/MODE Green • Indicate the MODE by the number of flashes when the installation function is active. (2) ERROR Flashes at high-speed when there is an error.
  • Page 558: 13-2.Outdoor Unit Low Noise Operation Function

    13-2. Outdoor unit low noise operation function Change the outdoor unit low noise operation by using this setting. CAUTION • When the low noise operation function is working, cooling and heating capacity will de- crease. • When changing the settings, explain to the customer beforehand that the capacity decreas- SET1-4 Setting Factory setting...
  • Page 559: Check And Test

    14. Check and test 14-1. Check run • The check run is a function to screen and detect any wiring errors. • After carrying out the check run, you can use the automatic wiring correction function to correct the wiring. •...
  • Page 560: Operating Procedure For Check Run

    ¢ Operating procedure for check run CAUTION Initiate check run after more than 12 hours after the power supply is connected. NOTE: Be sure that the indoor unit and outdoor unit are not operating before starting the check run. Press the CHECK switch for 3 seconds or more. CHECK The number of indoor units (and the places) connected through the communication lines is dis- played.
  • Page 561 After the check run is completed, results will be displayed. Fill the displayed results in the result table accordingly. • If the connection is correct (Example: When 4 indoor units are connected) After the number of connected units are displayed, the LED for each unit will light up in order from A to D.
  • Page 562 [How to record the contents] • Fill the displayed results according to the following example. Example: When piping A to D is connected but the wires for B and C are connected in reverse. <Displayed results> The LEDs will light up in 7 second intervals in the following order. POWER MONITOR ERROR...
  • Page 563 c. Select the correction method. Correct the wiring manually.*2 Proceed to step 6. Use the Automatic wiring correction function.*1 Proceed to step 5. Write down the same results in the label on the reverse side of the service panel. The results recorded are needed at the time of servicing. <Result Table>...
  • Page 564 ¢ Failure indication of check-run judgment The check run stops when there is an error, and the LED shows the relevant error indication. When you encounter the errors described here, perform checking by using the cooling test run of the indoor unit.
  • Page 565: 14-2.Test Run

    14-2. Test run CAUTION Always connect the power supply 12 hours prior to the start of the operation in order to protect the compressor. 1. Indoor unit a. Is the drain normal? b. Is there any abnormal noise and vibration during operation? 2.
  • Page 566: 14-3.Error Code

    14-3. Error code If an error occurs, the LED lights to inform the relevant location and the code. When error occurs, the error LED blinks at high speed. POWER ERROR MONITOR /MODE ( GRN ) ( RED ) blink (High speed) ¢...
  • Page 567: Error Code Display

    ¢ Error code display While the error is occurring, briefly push the SW1. The error code is displayed. Example: Coil error (Error cord = 9A.1) POWER ERROR MONITOR /MODE ( GRN ) ( RED ) [A(10)] Blink (High speed) (9-blink) Display mode LED on: Blink:...
  • Page 568: Error Type

    Error code Error type 11.3 Serial communication error 11.4 Serial communication error during operation 16.5 Communication error between controller and outdoor unit 22.1 Indoor unit capacity error 23.1 Connection prohibited (Series error) 5U.1 Indoor unit error 62.1 PCB model information error 62.3 EEPROM access error 62.8...
  • Page 569: Pump Down Operation

    14-4. Pump down WARNING During the pump down operation, make sure that compressor is off before you remove the refriger- ant pipe. Do not remove the connection pipe while the compressor is in operation with valve open. This may cause abnormal pressure in the refrigeration cycle that leads to breakage and even injury. ¢...
  • Page 570 7. Disconnect the power supply or turn off the breaker. NOTE: • Even if the pump down operation is not stopped by pushing the switch as in step 6, the operation stops automatically after 15 minutes, and the LED light as fol- lows.
  • Page 571: Accessories

    15. Accessories 15-1. Model: AOHG18KBTA3 Part name Exterior Part name Exterior Installation manual Drain pipe 15-2. Model: AOHG24KBTA3 Part name Exterior Part name Exterior Adapter K Installation manual 12.70 mm (1/2 in) to 9.52 mm (3/8 in) Drain pipe - 563 - 15-1.
  • Page 572: Outdoor Unit Installation Precautions

    16. Outdoor unit installation precautions NOTE: The information listed below are general precautions. Some models also include items that do not apply. 16-1. Places where prohibited for use • Places where there is a danger of combustible gas leakage. • Places where sulfur gas, chlorine gas, acid, alkali, or other matter which effects equipment is gen- erated.

Table of Contents