WARNING
!
Never install a single wall slip section or smoke pipe in a chase structure. The higher temperature of this single
wall pipe may radiate sufficient heat to combustible chase materials to cause a fire.
To avoid danger of fire, all instructions must be strictly followed, including the provision of air space clearance
between chimney system and enclosure. To protect against the effects of corrosion on those parts exposed
to the weather.
Maintain a minimum 2" (51mm) air clearance to all parts of the chimney system at all times. Failure to maintain
this 2" (51mm) air clearance will cause a structure fire.
Detailed instructions for installation of the storm collar and termination cap are supplied by the manufacturer
and are packaged with these parts.
Firestop spacers must be used whenever the chimney penetrates a ceiling/floor area.
The chimney must be sound and free of cracks. Clean your chimney a minimum of twice a year and as
required.
Always seal penetrations with temperature rated sealing products.
Installation of a combustible chase enclosure above the roof is permissible if done in accordance with the
chimney manufacturer's installation instructions.
4.1
chimney
note:
All venting connections must be in compliance with the chimney manufacturer's installation instructions.
This appliance was tested to CAN/ULC S610 and UL 127 Factory Built Fireplace Standards. This appliance has
met the test criteria for Zero Clearance Installation to Combustible Surfaces and Certified to burn firewood only.
Any chimney 10" (254mm) or 12" (30.5cm) diameter listed to CAN/ULC S610 for Canada or UL127 for the United
States or to the following standards; CAN/ULC-S604 and CAN/ULC-S629 for Canada or UL-103 or UL-103HT for
the United States may be installed.
Installation of all types of factory-built chimney systems is to be in accordance with the chimney manufacturers
installation instructions. An appropriate chimney manufacturers anchor base plate and anchor base plate gasket
is required in order to initiate their system. Use the high temperature gasket, supplied, to seal between the anchor
plate and the appliance top. Air cooled chimney systems are not
recommended in colder climates.
Chimney sections must be adequately secured one to the other to
ensure they do not separate. For complete installation instructions,
refer to instructions provided with the manufactured chimney system.
A chimney venting the appliance shall not vent any other appliance.
The minimum overall chimney height from the top of the appliance is
15ft (4.6m). The maximum overall chimney height from the top of the
appliance is 34ft (10.4m).
Factory-built chimney systems for use in dwellings constructed for
three or more families must be enclosed above the room in which the
appliance is located. This enclosure must have a fire resistance rating equal to or greater than that of the floor or
roof assembly through which they pass.
The chimney should not be built with an offset angle in excess of 45° in Canada and 30° in USA.
Ensure that minimum clearances are maintained.
Portions of the chimney that extend through accessible spaces must always be encased to avoid personal
contact with the chimney and thereby avoid damage to the chimney.
The chimney must be supported at a maximum of 20ft (6.1m) intervals. Every 20 ft (6.1m) of chimney can weigh
up to approximately 200lbs (90.7kg). When using a 10" chimney, center anchor plate to appliance flue outlet.
note:
Masonry chimney installs are not permitted.
installation
4.0 installation
ANCHOR PLATE
ANCHOR PLATE GASKET
APPLIANCE TOP
ANCHOR PLATE FOR A FACTORY
BUILT CHIMNEY
W415-1676 / C / 07.23.18
EN
17