Wiring diagram

7 - 1 Wiring diagram
REMHQ12P9
POWER SUPPLY
Position of M1~3C,M1,2F
El. compo. box
Detail of M1C~M3C
Detail of M1C~M3C
Indoor unit
A1P: Main
A4P,A8P: Fan
A1P~A8P
A2P: Noise filter
A5P: Sub
A3P: Inverter
A6P,A7P: Current sensor
Push button switch
BS1~BS5
(Mode, Set, Return, Test, Reset)
C1, C63, C66 Capacitor
E1HC~E3HC
Crankcase heater
F1U, F2U
Fuse (T, 3.15A, 250V) (A1P)
F1U
Fuse (T, 3.15A, 250V) (A5P)
F1U
Fuse (8A, DC650V) (A4P,A8P)
F5U
Field fusef
F400U
Fuse (T, 63A, 250V) (A2P)
Pilotlamp (service monitor -orange)
[H2P] Prepare, Test - - - - - - - - - - Flickering
H1P~H8P
Malfunction detection - - - - - - Light up
HAP
Pilotlamp (service monitor - orange)
K1: Magnetic relay
K2: Magnetic contactor (M1C)
K1~K4
K3: Magnetic relay
K4: Magnetic contactor (M1C)
K2M, K3M
Magnetic contactor (M2C, M3C)
L1R
Reactor
M1C~M3C
Motor (Compressor)
M1F, M2F
Motor (Fan)
PS
Switching power supply (A1P, A3P)
Q1DI
Earth leakage breaker
: Terminal
: Field wiring
: Connector
: Terminal
: Protective eart (screw)
NOTES
1
When using the option adaptor, refer to the installation manual
2
Refer to the installation manual, for connection wiring to
indoor-outdoor transmission F1 - F2, outdoor transmission F1 - F2,
outdoor-multi transmission Q1 - Q2 and on how to use BS1~BS5 and DS1, DS2 switch.
3
Do not operate the unit by short-circuiting protection device S1PH~S3PH
• Outdoor Units • VRV HEAT RECOVERY • REYHQ16-24P
K1R: K2M (A1P)
K2R: K3M (A1P)
K3R: Y1S (A1P)
K1R~K11R
K5R: Y3S (A1P)
K6R: Y7S (A5P)
K8R: E2HC (A1P)
K11R: Y4S (A1P)
Q1RP
Reverse phase detection circuit
R10
Resistor (current sensor) (A4P,A8P)
R50, R59
Resistor
R90
Resistor (current sensor)
R95
Resistor (current limiting)
R1T: Air (A1P)
R1T: Fin (A3P)
R1T~R9T
R2T: H/E Gas
R31T~R33T
R31T: M1C Discharge R7T: H/E Liquid
R32T: M2C Discharge R8T: Suction
R33T: M3C Discharge R9T: Liquid
S1NPH
Pressure sensor (High)
S1NPL
Pressure sensor (Low)
S1PH~S3PH Pressure switch (High)
SD1
Safety devices input
T1A
Current sensor (A6P, A7P)
Colors:
BLK:
Black
RED:
Red
YLW:
Yellow
WHT:
White
• VRV Systems • Outdoor Units
12 HP
TO
TO
TO
IN/D
OUT/D
MULTI
UNIT
UNIT
UNIT
Note 5
indoor
outdoor
outdoor
(F1)(F2)
(F1)(F2)
(01)(02)
Male connector: BLU
Female connector: WHT
MALE CONNECTOR: BLK
FEMALE CONNECTOR: WHT
Male conn: RED
Female conn: WHT
Magnetic relay
V1R
K1R: Y5S (A5P)
V2R
K2R: Y6S (A5P)
X1A~X4A
K4R: Y2S (A1P)
X5A
K5R: (for option) (A5P) X1M
K7R: E1HC (A1P)
X1M
K9R: E3HC (A1P)
Y1E
Y2E
Y3E
Y1S~Y3S
Thermistor
R4T: H/E Deicer
Z1C~Z10C
R5T: Sub cool H/E gas
Z1F
R6T: Sub cool H/E liq
Connector for optional parts
X7A
X9A
PNK:
Pink
BRN:
Brown
GRY:
Grey
GRN:
Green
Position in switch box
Front layer
Rear layer
Diode bridge (A3P)
Power module (A4P,A8P)
Power module (A3P)
Connector (M1F, M2F)
Connector (Y1E)
Terminal strip (Power supply)
Terminal strip (Control) (A1P)
Electronic expansion valve (Main)
Electronic expansion valve (Charge)
Electronic expansion valve (Subcool)
Solenoid valve
Y1S: RMTG
Y2S: 4 way valve (pipe)
Y3S: 4 way valve (H/E Gas)
Y4S: RMTL
Y5S: Hots gas
Y6S: EV bypass
Y7S: RMTO
Noise filter (ferrite core)
Noise filter (with surge absorber)
Operation output (A5P)
Power supply (ADAPTER) (A5P)
ORG:
Orange
BLU:
Blue
2TW29146-1A
3
1
7
30