  • Page 1 3PL Small Frame Operator’s & Parts Manual GA8701054 REV 0 - APR 2019...
  • Page 2: Table Of Contents

    Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Goldacres Warranty Statement . . . . . . . . . . . . .8 3PL - 600L .
  • Page 3: Introduction

    - we also keenly value the unique relationship we enjoy with owners of our equipment. We are pleased to welcome you as a Goldacres owner and look forward to making your spray applications as efficient as possible.
  • Page 4: Safety

    The following pages outline important • Care should be taken when transferring safety information. At Goldacres safety is liquid into the tank to ensure that the a high priority. These safety and warning gross weight of the equipment does...
  • Page 5 • Always read and understand the operators. All operators should be trained operator’s manual prior to operation of in the safe use of Ag chemicals. Goldacres this equipment. suggest that a relevant course is completed • It is the responsibility of the operator...
  • Page 6 It is very important to ensure that all new machine components and replacement parts include current hazard identification decals. Replacement safety decals can be ordered from all Goldacres dealers. Part No Description GA8700166 3PL Work Ready Base Kit GA8700167...
  • Page 7 • Contamination or corrosion of 2. If you continue to experience problems components then please contact your local authorised Goldacres dealer. They will advise the • Hose reel seal sand O-rings method of warranty service for your • Pressurised sprayer seals and O-rings product.
  • Page 8: Goldacres Warranty Statement

    Subject only to legislative obligations to the • Any Goldacres Product which has been repaired by other than an authorized Goldacres dealer in a contrary, Goldacres shall not be liable for incidental way which, in the sole and absolute judgment of or consequential damage resulting from ownership or use of a Product.
  • Page 9: Terms & Conditions

    Goods. Goldacres shall be under no liability for The benefit of any warranty provided under these terms and conditions shall only be damages arising out of the use of any chemicals, liquids, or mixtures in the Goods nor available to the Purchaser and shall not be transferable by the Purchaser;...
  • Page 10 Goods (section 132(2)); for Goldacres by way of bona fide sale at full market value and in the ordinary course of its to receive a statement of account if no disposal of Goods for each 6 month period (section business.
  • Page 11: General Information & Specifications

    Chassis The chassis is an all steel construction. The chassis is shot blasted, primed and then protected by the Goldacres paint process for excellent chemical resistance and durability. Tank Serial number...
  • Page 12: Dimensions

    Model Weight 450 L 150 kg (Empty, no booms) 1475mm 1058mm 600 L 180 kg (Empty, no booms) 3PL 600L 6m Boom 800 L 190 kg (Empty, no booms) 1000 L 240 kg (Empty, no booms) 1614mm 1355mm 3PL 800L...
  • Page 13: Key Features

    262.98 KG 0.00 ± 0.25 Boom Section Levers Zeta 70 Pump THIS DRAWING REMAINS THE PROPERTY DEBURR A OF GOLDACRES TRADING PTY LTD AND IS SHARP SUBJECT OF COPYRIGHT Pressure Adjustment PTO Shaft Fresh Water Hand Wash Tank Wet Sight Tube...
  • Page 14: Operation

    Operation Common Spraying Methods To ensure complete coverage in general field applications, Goldacres suggest that two spray swaths (depending on boom size fitted) are completed around the outside perimeter of the field. After completing the outside laps you will now have a wide headland on which to turn when completing the remaining sections moving up and down the length of the field.
  • Page 15 16. Run unit at operating speed until contents and lubricant applicator clean. Wipe all of tank are dispersed. dirt from the fittings before use. Goldacres 17. Take note of any water leaks, and tighten recommends that multi-purpose grease should fittings to rectify the problem immediately.
  • Page 16: Spray Control Manifold

    Spray Control Manifold Pressure Relief Valve The pressure relief valve provides relief when the pressure exceeds a pre-determined value. Altering the adjusting stem will affect the setting at which the relief valve will come into operation. Turning the stem clockwise will increase the pressure relief setting.
  • Page 17: Electric Controls

    Electric Controls through the appropriate rubber cabin grommets, and ensure the harness is located firmly. Bringing the harness through the back Optional electric controllers allow for on/ window of the tractor, then closing the window off switching of individual boom sections via can cause damage to the wires within the boom valves, as well as a pressure adjustment harness over time.
  • Page 18 Pressure Gauges functions. To increase the pressure for hand gun operation, or operating the venturi probe Testing has shown that there is a pressure for instance, turn the pressure regulator loss between the pressure gauge on the clockwise, which will wind more pressure on manual regulator and the pressure at the spray the spring inside the regulator.
  • Page 19: Control Station Taps

    Control station taps Electric Boom Valves The electric valves that control the boom Bypass tap section switching along with the electric All flow to the sprayer’s boom and electric bypass valve are located below the tank, pressure regulator is controlled by the bypass between the tank and boom.
  • Page 20: Calibrating Your Sprayer

    As part of your daily sprayer calibration, Goldacres suggest the use of a current TeeJet Goldacres suggests that you carry out a jug nozzle selection catalogue for reference to...
  • Page 21: Tasks Prior To Spraying

    Tasks prior to spraying 3. Then place the jug under one of the nozzles, for 60 seconds (exactly) and then record the volume of liquid collected. CAUTION: Before using this equipment with a chemical mix, read, and understand, the 4. Repeat the test over a representative instructions on the chemical label.
  • Page 22: Chemical Probe

    DATE the operator. The probe is used in conjunction 1-3 MORANG C 8. The pump needs to generate at least 100 GOLDACRES MITCHELL PARK PH: 03 53426399 with the Venturi filler (located on the top of the psi delivery pressure. Do not run the pump...
  • Page 23: Transporting Sprayer

    CAUTION: It is the operator’s responsibility to know the tare weight and gross weight of the sprayer. Contact your Goldacres dealer to ascertain a more precise tare weight for your sprayer if unsure. If any alterations are made to the sprayer, it is the operator’s responsibility to...
  • Page 24: End Of Spraying Day Tasks

    End of Spraying Day • Disconnect all lines between the sprayer and the tractor (i.e. hydraulic lines, foam Tasks marker lines, etc.) • Remove the PTO shaft from both the NOTE: Empty the spray tank by disposing of sprayer and the tractor. any residual spray in the appropriate manner.
  • Page 25: Folding Booms

    CAUTIONS The boom fitted as standard is part of the • Always ensure that there is adequate room Goldacres range of manual 'folding booms' for the boom to open. which are available in sizes from 3 metres • Always ensure that the boom is adequately to 8 metres.
  • Page 26: Filters

    Filters WARNING: Ensure that operator’s wear the appropriate PPE when cleaning filters. It is essential to maintain all filters, and filter screens, in good condition. Filter screens that are not regularly cleaned can severely impede the flow and thus affect delivery pressure. If the screen is in any way damaged, it can allow foreign material into the pumping system which can result in damage to the...
  • Page 27: Diaphragm Pump

    If this has not been done pumps are fitted as standard equipment and there is a possibility there may be on all Goldacres sprayers and are very well frozen water in the pump and/or in the suited to chemical spraying applications. To...
  • Page 28 • Insufficient lubrication of PTO shaft or binding of PTO shaft which can cause a side thrust to the internal components of the pump and overheat the pump and diaphragms. A change of oil colour indicates a pump problem. The oil should be regularly monitored when spraying so that any problem is detected as soon as possible.
  • Page 29: Diaphragm Pump - Zeta 70

    Diaphragm Pump - Zeta 70 Specifications Max Pump Capacity 70.5 L/min Max Pump Speed 540 RPM Max Pressure Capacity 20 BAR (290 PSI) Max Power Requirement 3.0 HP Oil Type SAE 30W40 GA5075793 GA5075684 GA5076495 GA5078313 GA5076070 GA5076070 GA5076074 GA5078283 GA5076443 GA5024655 GA5076534...
  • Page 30: Diaphragm Pump - Zeta 85

    Diaphragm Pump - Zeta 85 Specifications Max Pump Capacity 85 L/min Max Pump Speed 540 RPM Max Pressure Capacity 20 BAR (290 PSI) Max Power Requirement 3.0 HP Oil Type SAE 30W40 GA5075797 GA5076492 GA5076444 GA5076074 GA5076075 GA5076443 GA5076518 GA5076493 GA5076549 GA5076080 GA5076060...
  • Page 31: Diaphragm Pump - Troubleshooting

    Diaphragm Pump - Troubleshooting The troubleshooting information is provided all applicable troubleshooting solutions shown as a reference when your sprayer is not prior to calling your dealer, or Goldacres, for functioning correctly. service advice. To ensure that you receive the best possible...
  • Page 32 PROBLEM COMMON CAUSES COMMON SOLUTION The flow rate is correct Check nozzle chart for correct but my pressure is too Nozzles nozzle size. low or high. Check and clean all pressure Blocked filters of nozzles The pressure on gauge and nozzle filters is higher than the nozzle Flow loss due to resistance in Re-calibrate console to allow for...
  • Page 33 PROBLEM COMMON CAUSES COMMON SOLUTION PTO shaft is inadequately Lubricate PTO shaft and Damaged PTO shaft lubricated universal joints universal joint PTO shaft is too long Shorten PTO shaft PTO shaft not sliding freely or Check PTO shaft length and incorrect length lubricate.
  • Page 34: Filling

    Filling 4. Adjust the nozzle pattern as required by rotating the nozzle in the appropriate direction as required. When filling the sprayer it is necessary to use an external water source and wear the 5. Use a consistent speed or swath pattern appropriate PPE.
  • Page 35: Spray Gun - Gunjet Aa30L

    Spray Gun - GunJet AA30L The gunjet trigger needs to be locked via the No. AAB30L-¼, GunJet Spray Gun (BSPT trigger lock when not in use to prevent the Threads) gunjet from spraying inadvertently. AB30L-Kit - Spare Parts Kit (Includes all items marked with * and item 7) Pos.
  • Page 36: Spray Gun - Nozzle

    Spray Gun - Nozzle The adjustable brass ConeJet nozzle rotates through a half turn to provide spray selection from wide angle, finely atomized cone spray to a straight stream spray. NOTE: Tip settings “A” and “B” represent two extreme points of rotation in tip adjustment. Liquid Pressure (bar) Adjustable ConeJet Tip...
  • Page 37: 3Pl - 450L

    - Hose reel manual - Gun manual UNLESS OTHERWISE ± 1 - Spare controller tap and barb ± 0.5 - Current marketing material. 0.00 ± 0.25 • Wrap complete item with shrink wrap. THIS DRAWING REMAINS OF GOLDACRES TRADING SUBJECT OF COP...
  • Page 38: 3Pl - 600L

    3 Point Linkage Sprayer Frame 600L GA4907155 DRAWING CHECKED BY: THIS DRAWING REMAINS THE PROPERTY DEBURR AND BREAK OF GOLDACRES TRADING PTY LTD AND IS PTO shaft, Series 2, 860 mm, with quick release free SHEET 1 OF 4 SHARP EDGES DO NOT SCALE DRAWING...
  • Page 39: 3Pl - 800L

    ± 0.25 26/03/2019 GA4907160 DRAWING CHECKED BY: THIS DRAWING REMAINS THE PROPERTY DEBURR AND BREAK Pos. Part No. OF GOLDACRES TRADING PTY LTD AND IS Description Qty. SHEET 1 OF 5 SHARP EDGES DO NOT SCALE DRAWING SUBJECT OF COPYRIGHT...
  • Page 40: 3Pl - 1000L

    ANGULAR ± 0.50° WEIGHT: ± 0.5 262.98 KG 0.00 ± 0.25 THIS DRAWING REMAINS THE PROPERTY DEBURR AND OF GOLDACRES TRADING PTY LTD AND IS SHARP EDG SUBJECT OF COPYRIGHT Pos. Part No. Description Qty. GA4906615 Tank Assembly, 1000L, 3PL...
  • Page 41: Tank Assembly - 450-1000L

    DRAWING CHECKED BY: THIS DRAWING REMAINS THE PROPERTY GA5071270 Tank, 1000L with lid & 23L hand wash tank, Bare DEBURR AND BREAK OF GOLDACRES TRADING PTY LTD AND IS SHEET 1 OF 1 SHARP EDGES DO NOT SCALE DRAWING SUBJECT OF COPYRIGHT...
  • Page 42 Tank Assembly - 450-1000L Pos. Part No. Description Qty. GA5078498 Lid, Hinged, Black plastic, 355mm Filter, Basket type, Diameter 305 x 245mm deep, Suit main GA5076714 spray tank GA5069815 Screw Countersunk Phillips M4 x 20 ZP GA5020295 Valve, Ball, 12mm, 1/2" male, female, Lever handle, Brass GA5077704 Hose barb, Elbow, 90 degree, 1/2"...
  • Page 43: Frame Spare Parts - 450-800L

    GA4907155 DRAWING CHECKED BY: THIS DRAWING REMAINS THE PROPERTY DEBURR AND BREAK GA5016789 Top Link Pin, Dual Cat. OF GOLDACRES TRADING PTY LTD AND IS SHEET 2 OF 5 SHARP EDGES DO NOT SCALE DRAWING SUBJECT OF COPYRIGHT GA5007197 Clip R type 4 mm ZP S12...
  • Page 44: Frame Spare Parts - 1000L

    Washer 10mm Flat SS HD 0.00 ± 0.25 GA5000141 Nut M10 Nyloc ZP THIS DRAWING REMAINS THE PROPERTY OF GOLDACRES TRADING PTY LTD AND IS SUBJECT OF COPYRIGHT End cap, Plastic, Black, Insert, RHS. 50 x 50, 0.8 - 2.5mm GA5003783 wall GA5000931 Bolt M16 x 50 GR8.8 ZP...
  • Page 45: Foam Marker - 450-1000L

    ± 0.5 GA5053065 0.00 ± 0.25 droppers, double sided THIS DRAWING REMAINS THE PROPERTY OF GOLDACRES TRADING PTY LTD AND IS GA5078420 Foam Marker Generator, Vertical, Complete end (old style) SUBJECT OF COPYRIGHT GA5023110 Foam Marker Generator, Horizontal, Complete end...
  • Page 46: Step - 600-800L

    Step - 600-800L ITEM NO. PART NUMBER DESCRIPTION QTY. Pressed step tread bolt in 370mm wide GA5072535 painted Pos. Part No. Description Qty. Plate, Step Bracket 600L and 800L GA4508495 Frame 3 Point Linkage 2014 GA5070535 Step Tread Pressed bolt in 370mm wide painted GA4508495 Plate, Step Bracket GA5065455...
  • Page 47: Hose Reel - 450-1000L

    Hose Reel - 450-1000L ITEM NO. PART NUMBER DESCRIPTION QTY. Pos. Part No. Description Qty. Hose reel, 30m 3/8" hose, manual GA5066080 rewind GA5066080 Hose reel, 30m 3/8" hose, manual rewind GA5006161 Bolt M10 x 25 GR8.8 ZP GA5006161 Bolt M10 x 25 GR8.8 ZP GA5000117 Washer 10mm Flat SS HD GA5000117...
  • Page 48: Suction Filter - 450L

    108.59 KG NEALHARVEY DRAWING NUMBER: SHEET ± 0.25 18/03/2019 GA4907150 DRAWING CHECKED BY: THIS DRAWING REMAINS THE PROPERTY DEBURR AND BREAK OF GOLDACRES TRADING PTY LTD AND IS SHEET 2 OF 3 SHARP EDGES DO NOT SCALE DRAWING SUBJECT OF COPYRIGHT...
  • Page 49: Suction Filter - 600-1000L

    NEALHARVEY DRAWING NUMBER: SHEET 0.00 ± 0.25 22/03/2019 GA4907165 DRAWING CHECKED BY: THIS DRAWING REMAINS THE PROPERTY DEBURR AND BREAK OF GOLDACRES TRADING PTY LTD AND IS SHEET 3 OF 3 SHARP EDGES DO NOT SCALE DRAWING SUBJECT OF COPYRIGHT...
  • Page 50: Spray Manifold 450-1000L Non-Boom Valve

    Spray Manifold - 450-1000L - Non-Boom Valve Pos. Part No. Description Qty. GA2000051 Pressure control valve, manual, constant, 4 way, Geoline GA5000999 3/4" SS hose clamp GA5000469 Hose clamp, 1/2", SS GA5004711 Bolt M8 x 25 GR8.8 ZP EM NO. PART NUMBER DESCRIPTION QTY.
  • Page 51: Spray Manifold - 800-1000L - Boom Valve

    Spray Manifold - 800-1000L - Boom Valve PART DESCRIPTION NUMBER Pos. Part No. Description Qty. GA2000560 Pressure control valve, manual, constant, 2 way, Geoline GA2000051 Pressure control valve, manual, constant, 4 way, Geoline GA5000999 3/4" SS hose clamp GA5000999 3/4" SS hose clamp GA5000469 Hose clamp, 1/2", SS GA5000469...
  • Page 52: Spray Manifold Assembly - Non-Boom Valve

    Plumbing Manifold, 4-6 Sections, Geoline Bar, 1/4", coloured scale, Geoline DRAWIN THIS DRAWING REMAINS THE PROPERTY DEBURR AND BREAK OF GOLDACRES TRADING PTY LTD AND IS SHARP EDGES Plumbing fitting, Hose barb 13mm, elbow, With oring, SUBJECT OF COPYRIGHT GA2000056...
  • Page 53: Spray Manifold Assembly - Boom Valve

    Plumbing fitting, Hose barb 13mm, elbow, With oring, DRAWING CHECKED GA2000056 THIS DRAWING REMAINS THE PROPERTY DEBURR AND BREAK OF GOLDACRES TRADING PTY LTD AND IS outlet, Geoline SHARP EDGES SUBJECT OF COPYRIGHT Plumbing fitting, Hose barb 25mm, elbow, With oring, Inlet,...
  • Page 54: Plumbing Manifold Assembly

    NEALHARVEY DRAWING NUMBER: SHEET 0.00 ± 0.25 28/03/2019 GA2000086 DRAWING CHECKED BY: THIS DRAWING REMAINS THE PROPERTY DEBURR AND BREAK OF GOLDACRES TRADING PTY LTD AND IS SHEET 1 OF 1 SHARP EDGES DO NOT SCALE DRAWING SUBJECT OF COPYRIGHT...
  • Page 55: Pump - 450-800L

    GA5000141 Nut M10 Nyloc ZP Tensile UNLESS OTHERW GA5000999 Hose Clamp, 3/4", SS (16-27/12W) GA5000141 Nut M10 Nyloc ZP ± 1 ± 0.5 GA5000999 3/4" SS hose clamp 0.00 ± 0.25 THIS DRAWING REMA OF GOLDACRES TRAD SUBJECT OF C...
  • Page 56: Boom Valves - 800-1000L

    Boom Valves - 800-1000L ITEM NO. PART NUMBER DESCRIPTION QTY. Pressure control valve, electric, Pos. Part No. Description Qty. GA2000052 3 way, Geoline GA3000065 Switch box, control 4 boom valves, 4V+P+G RD, Geoline Support Bar, For Electric Valves, GA3000064 Electrical harness, 5m extension, boom valves, Geoline GA4403145 Suit 3PL Pressure control valve, electric, 3 way, 3/4"...
  • Page 57: Boom Mounting Fasteners

    OPEN DIM ± 1.00 IN MILLIMETRES ANGULAR ± 0.50° Surface Finish: THIS DRAWING REMAINS THE PROPERTY UNLESS OTHERWISE OF GOLDACRES TRADING PTY LTD AND IS REV NO CHANGE NAME/DATE ECN NO. TOLERANCED DRG. STANDARD SUBJECT OF COPYRIGHT /PRACTICE DEBUR ALL EDGES...
  • Page 58: Chemical Probe Assembly

    Washer 8mm Flat SS HD GA4907160 Surface Finish: Drawing Checked: ANGULAR ± 0.50° IS DRAWING REMAINS THE PROPERTY UNLESS OTHERWISE F GOLDACRES TRADING PTY LTD AND IS GA5052590 Nut M8 Nyloc SS Approved TOLERANCED DRG. STANDARD BJECT OF COPYRIGHT /PRACTICE...
  • Page 59: Venturi Filler Assembly

    QTY. Venturi Filler Assembly bled 4" /4 x 1/2 ut 405mm 1 1/2 he parts in the kit are used REV NO CHANGE GOLDAC Pos. Part No. Description Qty. GA4903086 Venturi filler, Pre assembled, to mount in top of tank TITLE: GA5007235 Hose clamp, Cobra type, 1 1/2”...
  • Page 60: Goldacres

    www.goldacres.com.au...

This manual is also suitable for:

3pl 450l3pl 800l3pl 1000l

Table of Contents