Error Messages

Main Unit
If any of the messages below appear on the Display window of the Main Unit, check the following table to solve the
problem. If any problem persists, consult your nearest Sony dealer.
Message
PROTECTOR ZONE1
PROTECTOR ZONE2
PROTECTOR ZONE3
PROTECTOR ZONE4
PROTECTOR ZONE5
PROTECTOR ZONE6
FAN STOP
CONNECTION ERROR
STR
CONNECTION ERROR
DVD MEGA
CONNECTION ERROR
CD MEGA
CONNECTION ERROR
PC
CONNECTION ERROR
RF REMOTE
EEP ACCESS FAIL
MEMORY FULL
Keypad
If any of the messages below appear on the display window of the Keypad, check the following table to solve the problem.
If any problem persists, consult your nearest Sony dealer.
Message
CONNECTION NOT
ESTABLISHED
PROTECTOR
FAN STOP
PLEASE CHECK
MODE SELECTOR
CANNOT ACCESS NOW
SOURCE NOT AVAILABLE!
LOCKED BY OTHER ZONE
LOCKED BY MAIN ZONE
NOT USED
Cause
Protective device in zone 1 has been activated. Turn off the Main Unit and check the speaker hookup.
Protective device in zone 2 has been activated. Turn off the Main Unit and check the speaker hookup.
Protective device in zone 3 has been activated. Turn off the Main Unit and check the speaker hookup.
Protective device in zone 4 has been activated. Turn off the Main Unit and check the speaker hookup.
Protective device in zone 5 has been activated. Turn off the Main Unit and check the speaker hookup.
Protective device in zone 6 has been activated. Turn off the Main Unit and check the speaker hookup.
The fan does not rotate.
A communication error with the A/V Receiver An error occurred due to an unsupported connection.
(STR) has occurred.
A communication error with the DVD MEGA
CHANGER has occurred.
A communication error with the CD MEGA
CHANGER has occurred.
A communication error with the computer has An error occurred due to an unsupported connection.
occurred.
A confirmation error with the RF Remote
Control has occurred.
The Main Unit failed to access the EEPROM.
The Memory capacity for storing EEPROM
code has been exceeded during the remote
code learning.
Cause
The Keypad failed to communicate with
the Main Unit.
Protector is detected by the Main Unit.
The fan of the Main Unit does not rotate.
Mode selector switch setting is wrong.
Multiple Keypads tried to access
the same source component.
An inactive source was selected.
The selected source was locked by another
zone.
The selected source was locked by the main
zone.
An inactive button was selected.
Corrective action
Turn off the Main Unit and check that if any objects are
inside the fan unit.
An error occurred due to an unsupported connection.
An error occurred due to an unsupported connection.
Ask your nearest Sony dealer.
Ask your nearest Sony dealer.
Some remote codes cannot be learned even if the memory
capacity used for learning has not been exceeded.
Corrective action
Turn off the Main Unit and check the CAT5 connections.
Turn off the Main Unit and check the speaker connections.
Turn off the Main Unit and check that the ventilation holes
are not covered.
Check that the Mode switch on the rear panel of the
Keypad is in the correct position.
Wait for a few seconds and try again.
Select the appropriate source connected to the Main Unit.
You cannot operate a locked source until it is unlocked.
You cannot operate a locked source until it is unlocked.
Some buttons are not assigned for certain sources.
ex.) PLAY cannot be operated in the TUNER position.