Electrical connection

This heater must be used on an ~ supply only and the
voltage marked on the heater must correspond to the
supply voltage. This heater is fitted with a rewirable plug
incorporating a 13 amp fuse. In the event of replacing the
fuse in the plug supplied, a 13 amp fuse approved by ASTA
to BS 1362 must be used. If any other type of plug is used,
a 15 amp fuse must be fitted in the plug, the adaptor, or at
the distribution board.
IMPORTANT : If the plug is not suitable for your socket,
the 13 amp plug should be removed. Before wiring the
appropriate plug, please note that the wires in this mains
lead are coloured in accordance with the following code :
BLUE :
BROWN :
As the colours of the wires in the mains lead may not
correspond with the coloured markings in your plug, proceed
as follows :
Connect the BROWN wire to the terminal marked 'L' or coloured
RED. Connect the BLUE wire to the terminal marked 'N' or
coloured BLACK. Note : 'L' or 'N' wire must not be connected to
terminal marked 'E' or '
the EARTH
GREEN AND YELLOW. If in doubt, consult your electrician.
Operation
Switch – see Fig. 1
With the selector switch, the fan can be switched on or the
heat setting selected. The power indicating light illuminates
when the Switch is turned on.
Thermostat – see Fig. 1
In order to maintain a certain room temperature, set the
controller to 'max.'. Operate the appliance at full power
until the required room temperature is reached. Set back
the thermostatic controller until the appliance switches off
with an audible 'click'. This temperature will be kept almost
constant by the thermostatic control switching on and off
automatically. Please note that the appliance can only be
switched on when the thermostat setting is higher than the
room temperature.
With the thermostat knob set to ' ' and the switch knob
set to the required heating output the appliance switches
on automatically when the temperature falls below +5°C -
+8°C.
Safety
Overheat Protection
For your safety, this appliance is fitted with a thermal cut-out.
In the event that the product overheats, the cut-out switches
the heater off automatically.
To bring the heater back into operation, remove the cause of
the overheating, then unplug or turn off the electrical supply
to the heater for a few minutes. When the heater has cooled
sufficiently, re-connect and switch on the heater.
NEUTRAL
LIVE
' or coloured GREEN or
DO NOT COVER
Fig. 1
Fuselink
A thermal fuse link is provided as an added safety feature.
If the fuse link operates and opens circuit it is the result of
abnormal overheating within the appliance and servicing
of the appliance by a competent service engineer will be
required in order to ensure the future safe operation of the
heater. Customer services should be contacted, who will
arrange the replacement of any faulty parts and the fitting
of a new fuse link.
Cleaning
Switch off the appliance first and disconnect the plug from
the socket. Clean the housing with a moist cloth, vacuum
cleaner or brush. Do not use any abrasive or caustic
cleaning agents. Do not use any flammable cleaning
agents e.g. petrol or spirit for cleaning the appliance.
Never immerse the appliance in water. Air inlet and outlet
area should be cleaned with a vacuum cleaner regularly. If
the appliance is not used for extended periods, it must be
protected against excessive dust and dirt.
Recycling
For electrical products sold within the
European Community. At the end of the
electrical products useful life it should not
be disposed of with household waste.
Please recycle where facilities exist. Check
with your Local Authority or retailer for
recycling advice in your country.
Model Identifier(s):
Heat output
Nominal heat output
Minimum heat output (indicative)
Maximum continuous heat output
Auxiliary electricity Consumption
At nominal heat output
At minimum heat output
In standby mode
Type of heat output/ room temperature control
Mechanical thermostat room temperature control
Contact details
DXUC2B
Pnom
2.0
Pmin
1.1
Pmax,c
2.0
elmax
0.0
elmin
0.0
elSB
0.0
GDC Group Limited
Millbrook House, Grange Drive, Hedge
End, Southampton.
SO30 2DF
Telephone: 0844 879 3588
Email:
customer.services@gdcgroup.co.uk
Visit: www.gdcgroup.co.uk
kW
kW
kW
kW
kW
kW
Yes

Advertisement

loading