Renogy RNG-300D Installation Manual

Renogy RNG-300D Installation Manual

Photovoltaic (pv) modules
Hide thumbs Also See for RNG-300D:

Advertisement

INSTALLATION GUIDE FOR
PHOTOVOLTAIC (PV) MODULES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RNG-300D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Renogy RNG-300D

  • Page 1 INSTALLATION GUIDE FOR PHOTOVOLTAIC (PV) MODULES...
  • Page 2: Table Of Contents

    Contents Purpose of this Guide ..........................3 1.1. Disclaimer of Liability ......................... 3 1.2 General Safety ............................. 3 1.3 Safety Precaution Measures ....................... 3 Product Identification ........................... 4 Installation Considerations ........................4 3.1 Unpacking and Storing ........................4 3.2 Pre-Installation Requirements ......................4 3.3 Site Considerations ..........................
  • Page 3: Purpose Of This Guide

    If modules are connected in parallel, the total current is equal to installation, operation, use or maintenance. the sum of individual module currents. No responsibility is assumed by Renogy for any infringement of  patents or other rights of third parties, which may result from use of Keep children well away from the system while transporting and ...
  • Page 4: Product Identification

    Ensure the supporting roof has fire resistant roof covering  operating at a voltage above 50 VDC or power above 240 W, where Renogy modules are listed as Class C under the UL790 Standard.  general contact access is anticipated.
  • Page 5: Site Considerations

     Renogy modules are designed with a mechanical load strength of 2400Pa 3.4 System Fire Rating The fire rating of Renogy modules is only valid when mounted in the manner specified in the mechanical mounting instructions. When Mounting Holes installing modules on rooftops, please ensure the assembly is mounted (Length * Width): over a fire resistant roof covering rated for the application.
  • Page 6: Top Down Clamps

    We recommend the lay-in lug (Cat. No. GBL4-DBT; rated for  Clamps are an approved method of mounting for Renogy modules. A 600Volts; company: ILSCO; UL number is E34440 ) when clamp holds two modules in a row. The centerline of the clamps must be grounding.
  • Page 7: Bypass Diodes

    MC4 adaptor for parallel strings. Renogy recommends that only sunlight resistant cables be used with the minimum wire size being 4mm in diameter. Wiring Type Ratings PV Wire Rated Voltage: 1800VDC PV1-F1x4.0mm...
  • Page 8: General Installation

    These currents can cause the affected cells to get very hot and Renogy recommends that all work in commissioning and maintenance of could even damage the module. To protect module from such high...
  • Page 9: Maintenance

    5 percent, this indicates a bad electrical connection. 6.2 Maintenance Renogy recommends the following maintenance in order to ensure optimum performance of the module: Clean the glass surface of the module as necessary. Always use ...