Description Mode 2 - Magnetic Autocontrol MPR 112 Operation And Installation Instructions Manual

Retractable flap barrier
Table of Contents

Advertisement

Functional description of MBC110
IN1
IN 2
Emergency
Open left
0
x
1
x
1
pulse
1
x
1
pulse
1
1
1
x
1
1
1
pulse
1
1
0 = not active; 1 = active; x = non relevant
581E,5721/ 07/2006 MPR112_1
Version: 01

8.4 Description Mode 2

Mode 2 allows free entry or exit in both directions. This requires the
installation of two PE beams at the end of the barriers close to the
card readers (standard).
The two light beams can have two functions. First it allows free entry
or exit by opening the flaps when a person comes from the correct
direction, and secondly it allows the controller to detect persons
coming from an incorrect direction, hence the barrier remains
closed.
Note!
The gate is always in status closed (except Emergency and fully
free), if no opening pulses are interpreted (closed mode).
Mode 2 allows the following setup:
Emergency, Out-of-service, Entry, Exit, Bi-directional, Free Entry,
Free Exit, Free Entry – Controlled Exit, Controlled Entry – Free Exit,
Fully Free
The operation modes are controlled via the inputs IN1 to IN5..
IN4
IN3
Passage left
Open right
enabled
x
x
x
0
x
1
pulse
0
pulse
1
x
1
1
0
pulse
1
1
1
1
1
IN5
Resulting Operation
Passage right
enabled
x
Emergency
0
Out of Service
0
Entry
1
Exit
1
Bi-directional
0
Free Entry
1
Free Exit
1
Free Entry, controlled exit
1
Free Exit, controlled entry
1
Fully Free
mode
page 43/72

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents