Hydraulically Connecting The Axial Piston Unit - Bosch Rexroth 31 Series Instruction Manual

Axial piston variable pump
Hide thumbs Also See for Rexroth 31 Series:
Table of Contents

Advertisement

36/60
Installation
notices on routing lines
Bosch Rexroth AG, A10VO, A10VSO Series 31, RE 92701-01-B/04.2018
3.
For the version wit through drive, first remove the spacer (4), see section 7.4.7
"Remove the spacer (for version with through drive)" on page 34 and fit
the auxiliary pump in accordance with the pump manufacturer's instructions.
The protective cover (3) is not pressure-resistant and thus not permissible in
operation.
7.4.9

Hydraulically connecting the axial piston unit

Insufficient suction pressure!
Generally, a minimum permissible suction pressure at port S is specified for axial
piston pumps in all installation positions. If the pressure at port S drops below the
specified values, damage may occur which may lead to the axial piston pump being
damaged beyond repair.
Make sure the necessary suction pressure is maintained. This is influenced by:
– The piping (for example, suction cross-section, pipe diameter, length of
suction line)
– The position of the reservoir
– The viscosity of the hydraulic fluid
– A filter element or check valve in the suction line (check the level of
contamination of the filter element regularly)
The machine/system manufacturer is responsible for sizing the lines. Connect the
axial piston unit to the rest of the hydraulic system in accordance with the hydraulic
circuit diagram of the machine/system manufacturer.
The ports and fastening threads are designed for the maximum permissible
pressures p
, see Table 11 "Ports A10VO/A10VSO Series 31" on page 38.
max
The machine/system manufacturer should make sure the connecting elements and
lines correspond to the specified application conditions (pressure, flow, hydraulic
fluid, temperature) with the necessary safety factors.
Connect only hydraulic lines that are match the axial piston unit port (pressure
level, size, system of units).
Observe the following information when routing the suction, pressure and drain
lines.
• Lines and hoses should be installed without pre-charge pressure so no further
mechanical forces are applied during operation that will reduce the service life
of the axial piston unit and, possibly, the entire machine/system.
• Use suitable seals as sealing material.
• Suction line (pipe or hose)
– The suction line should be as short and straight as possible.
– Measure the line cross-section of the suction line so the pressure at the suction
port does not drop below the min. permissible pressure. Make sure that the
maximum suction pressure is not exceeded (for example, when pre-filling).
– Make sure the connections and connecting elements are airtight.
– The hose must be pressure-resistant, also to external air pressure.
• Pressure line
NOTICE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth a10v0Rexroth a10vsoA10vsoA10vo32 seriesA10vsno

Table of Contents