42/60
Installation
Tightening torque for
Hirschmann connectors
Bosch Rexroth AG, A10VO, A10VSO Series 31, RE 92701-01-B/04.2018
On axial piston units with a Hirschmann connector according to DIN EN 175 301-803-A/
ISO 4400, the following tightening torques apply when securing plug-in connectors:
• Mounting bolt, M3 (1): 0.5 Nm
• Union nut M16 × 1.5 (2): 1.5-2.5 Nm
1
2
Fig. 15: HIRSCHMAnn connector

7.5 Performing flushing cycle

In order to remove foreign particles from the system, Bosch Rexroth recommends a
flushing cycle for the entire system prior to initial commissioning. To avoid internal
contamination, do not include the axial piston unit in the flushing cycle.
Use an additional flushing unit to perform the flushing cycle. Follow the
instructions of the flushing unit's manufacturer for the exact procedure during the
flushing cycle.