INSTALLATION INSTRUCTIONS
A. Prepare the Outdoor Unit for Installation
• Remove all packaging.
• Place supplied vibration pads onto outdoor
unit's feet.
• Place the unit on a solid foundation, 8" above
the average snowfall.
31-5000001 Rev. 1
Step 3 - Installation of the Outdoor Unit
B Attaching Drain Elbow to Outdoor Unit
• If required, attach the supplied drain elbow to
the outdoor unit. Connect extension piping as
needed (not supplied). (see illustration)
NOTE: The drain elbow is designed with an
air gap and will not sit flush to bottom of the
outdoor unit.
NOTE: Arctic Multi models will not use a drain
elbow. If condensate management is required
by code, a 3rd party pan is needed.
13