Panduit OptiCam 2 FS133 User Manual

Panduit OptiCam 2 FS133 User Manual

Termination tool

Advertisement

OptiCam 2 FS133 Termination
Tool User Manual
Release 1
Issue 2

Advertisement

Table of Contents
loading

Summary of Contents for Panduit OptiCam 2 FS133

  • Page 1 OptiCam 2 FS133 Termination Tool User Manual Release 1 Issue 2...
  • Page 2 OptiCam 2 FS133 Termination Tool User Manual Copyright © 2019 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any means, elec- tronic, mechanical, photocopying, recording or otherwise, without written permission from Panduit. No patent liability is assumed with respect to the use of the information contained herein.
  • Page 3: Table Of Contents

    OptiCam 2 FS133 Termination Tool User Manual Table of Contents OptiCam 2 FS133 Termination Tool Overview Safety Precautions Safety Glasses Isopropyl Alcohol (92% or better) Disposal of Bare Fibers Laser Light Cable Handling Tool Set Up Component Identification Buffer Stripping Steps 250μm Coated Fiber Strip...
  • Page 4 OptiCam 2 FS133 Termination Tool User Manual Insert Cleaved Fiber Cam Connector Review Test Results Assemble Connector and Boot LC Connector and Boot SC Connector and Boot ST Connector and Boot Tool Care and Maintenance Connect-It App Use - 4 -...
  • Page 5: Opticam 2 Fs133 Termination Tool Overview

    Place tool, launch cord, and cradle in a protective case. Tool Use This tool is to be used for the termination of Panduit OptiCam connectors only. The tool emits a non-visible laser beam, which, when used in conjunction with the launch cord and cradle, aids in proper connector termination.
  • Page 6 OptiCam 2 FS133 Termination Tool User Manual This tool contains no user-serviceable parts. The laser output is not adjustable. Contact Panduit Corp. for service needs. Do not Throw Away This symbol indicates the need for separate collection of electrical and electronic equipment waste. Separating electronic waste can halt the potential adverse effects on the environment and human health as a result of the hazardous substances in electrical and electronic equipment.
  • Page 7: Safety Precautions

    OptiCam 2 FS133 Termination Tool User Manual Safety Precautions Safety Glasses WARNING: It is strongly recommended that safety glasses be worn when handling bare optical fiber. The bare fiber is very sharp and can easily damage the eye. Isopropyl Alcohol (92% or better) WARNING: Flammable.
  • Page 8: Cable Handling

    OptiCam 2 FS133 Termination Tool User Manual CAUTION: Use of controls of adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Never point the laser into the eyes of others Do not stare directly at the laser beam.
  • Page 9: Tool Set Up

    OptiCam 2 FS133 Termination Tool User Manual Tool Set Up Various components of the OptiCam 2 Tool: 1. Select the proper Launch Cord and Cradle. For each connector type, select the correct launch cord and cradle for ter- mination use.
  • Page 10 OptiCam 2 FS133 Termination Tool User Manual 2. To load or replace batteries, remove the battery cover using a Phillips screwdriver. 3. Insert 2 size AA (type L91) 1.5volt Lithium Iron Disulfide batteries, follow the polarity markings in the compartment. Then replace the cover and secure it using the Phillips screw driver.
  • Page 11 OptiCam 2 FS133 Termination Tool User Manual 7. Please refer to the Connector Type, Launch Cord, and Cradle Cross Reference Table to make sure you are using the proper combination of cord, cradle, connector, and orientation. 8. When attaching the metal adapter to the cradle for LC terminations, the opening on the side of the barrel should be placed facing the tool.
  • Page 12 OptiCam 2 FS133 Termination Tool User Manual 11. Use the navigation button to navigate to the menus and to Connector Type , and select the correct connector options: Menu > Connector Type. 12. Use the navigation button to select the correct information. The selected text will become red. Click Save.
  • Page 13 System Menu on the tool. 17. Update the tool to the most recent firmware available at Panduit.com > Support > Download Center > Soft- ware/Firmware/Printers > OptiCam 2 Termination Tool.
  • Page 14: Component Identification

    OptiCam 2 FS133 Termination Tool User Manual Component Identification LC Connectors, Launch Cord, and Cradle SC Connectors, Launch Cord, and Cradle ST Connectors, Launch Cord, and Cradle Alignment Key must be in the alignment tab to cam properly. Additionally, the flat sides on the back bone will line up into the key slot of the cradle with the etched, rounded side facing down.
  • Page 15 OptiCam 2 FS133 Termination Tool User Manual Connector Types with Colors Fiber Type Backbone Color (LC, SC) Boot Color OM3, OM4 (50µm) Aqua Aqua OM2 (50µm) Black Black OM1 (62.5µm) Beige Beige OS1, OS2 (Single mode) Blue Blue - 15 -...
  • Page 16: Buffer Stripping Steps

    OptiCam 2 FS133 Termination Tool User Manual Buffer Stripping Steps 250μm Coated Fiber Strip 1. Install the boot. Insert the fiber end through the small end of the boot. Slide the boot back out of the way. 2. Place one build-up tube (F250BT) onto the fiber and slide it back out of the way.
  • Page 17: Jacketed Cable Strip

    OptiCam 2 FS133 Termination Tool User Manual Jacketed Cable Strip 1. If using duplex cable, split the two cables approximately 6" (152mm) or as needed. 2. Following the stripping dimensions, use the marking pen to mark the cable jacket at 1.89”...
  • Page 18: Buffer Stripping

    OptiCam 2 FS133 Termination Tool User Manual 3. To reduce the amount of fiber movement, place a drop of adhesive (Loctite 401 or equivalent Cyanoacrylate adhesive) at the point that the coated fibers exit the 3mm cable jacket. 250μm coated fibers need to be taut between cable jacket and the fanout tube assembly.
  • Page 19: Cleave Fiber Steps

    OptiCam 2 FS133 Termination Tool User Manual Cleave Fiber Steps Prep Stripped Fiber 1. Remove and dispose of any remaining fiber scraps in the cleaving tool. 2. Clean bare fiber using an isopropyl alcohol (92% concentration) soaked lint-free wipe. The fiber should be free of all coating and residue.
  • Page 20 OptiCam 2 FS133 Termination Tool User Manual IMPORTANT: Do not clean fiber after cleaving. Replace the ceramic blade in the cleaving tool after every 1000 cleaves, or if installation yield decreases. Replacement blades (FJQCVRB) are available. - 20 -...
  • Page 21: Opticam 2 Tool Operation - Lc

    OptiCam 2 FS133 Termination Tool User Manual OptiCam 2 Tool Operation - LC Select Connector Options 1. Use the navigation button to navigate to the menus and to “Connector Type”, and select the correct connector options: Menu > Connector Type.
  • Page 22: Connector Test

    OptiCam 2 FS133 Termination Tool User Manual Note: Each connector has slightly different cradle operation. Refer to the individual connectors’ specific instructions in the Tool Set Up section. Connector Test To start the connector test, select the Next icon, pressing the navigation button directly down. The tool will perform a background test of the connector.
  • Page 23: Cam Connector

    OptiCam 2 FS133 Termination Tool User Manual Cam Connector LC Camming requires that the whole connector rotate. When the screen displays the CAM & Test command, A) Maintain gentle forward pressure on the field fiber, and B) “Cam” the connector, then select the Next arrow to perform the test.
  • Page 24 OptiCam 2 FS133 Termination Tool User Manual If the IL does not meet your project requirements, select the cancel icon and repeat the fiber termination process for that con- nector ID. Selecting forward advances the connector ID number for the tool to do another termination. In both cases, the results will be recorded in the tool for later retrieval.
  • Page 25: Assemble Connector And Boot

    OptiCam 2 FS133 Termination Tool User Manual Assemble Connector and Boot LC Connector and Boot 1. Grip the boot by the large end and push the boot forward onto the grooved area of the backbone until it is against the flange.
  • Page 26: Sc Connector And Boot

    OptiCam 2 FS133 Termination Tool User Manual SC Connector and Boot 1. Grip the boot by the large end and push the boot forward onto the grooved area of the backbone until it is against the flange. The insertion mark should be at end of backbone.
  • Page 27: St Connector And Boot

    OptiCam 2 FS133 Termination Tool User Manual ST Connector and Boot 1. Grip the boot by the large end and push the boot forward onto the grooved area of the backbone until it is against the flange. The insertion mark should be at end of backbone.
  • Page 28: Tool Care And Maintenance

    OptiCam 2 FS133 Termination Tool User Manual Tool Care and Maintenance 1. The LC connector port and data port protective dust caps must be installed when the tool is not in use to prevent contamination. 2. The camera aperture should be cleaned periodically with a soft, lint free cloth or with isopropyl alcohol to remove dust and debris which may interfere with proper camera operation.
  • Page 29 OptiCam 2 FS133 Termination Tool User Manual Note: 1.25 millimeter cord is shown for reference. The process is the same for the 2.5 millimeter cord. 5. Twist the split sleeve and pull to remove it from the assembly, exposing the tip of the fiber.
  • Page 30 OptiCam 2 FS133 Termination Tool User Manual 8. If there is stubborn debris on the ends after dry cleaning, use this method: Using the cleaning solution, moisten one end of a row on the cleaning box. Drag the tip of the fiber along the fiber cleaning row (example shown in blue) from the wet area to the dry area.
  • Page 31: Connect-It App Use

    App Overview 1. Navigate to the menus of the OptiCam 2 tool and select: Tool Settings > Wireless > On. Then select Exit. 2. Enter the wireless password given when registering the tool at Panduit.com. 3. Turn wireless on. Note: The tool name is found under Menus > Tool Settings > Tool Name. Rename for ease of use.
  • Page 32 OptiCam 2 FS133 Termination Tool User Manual 5. Connect to the OptiCam 2 tool by pulling down to refresh the list and selecting the appropriate tool name from the list. Then select Start Project. 6. The app will indicate that the tool has un-synced records if terminations were done on the tool without the app and tool being synced.
  • Page 33 OptiCam 2 FS133 Termination Tool User Manual 7. To export the connector termination data, navigate to the “Project Overview” and select the current project. There are three available options: a. Share – enables the file to be emailed; b. Select – opens the file;...
  • Page 34 OptiCam 2 FS133 Termination Tool User Manual 12. Verify the connector type in the Test Window, and then install the connector into the cradle and select Load Connector. The tool will perform a Background Test and automatically display Insert Fiber.
  • Page 35 OptiCam 2 FS133 Termination Tool User Manual 17. If needed, re-test by using the Re-test icon, or re-terminate using the ReTerminate icon and repeat the fiber clean and cleave steps. The OptiCam connector can be reused up to three times.

Table of Contents