Operating Specifications - Pentair EVERPURE CONSERV LT-S Manual

High efficiency reverse osmosis (ro) processor
Table of Contents

Advertisement

WARNING: Before installing the Processor, make
certain your water supply complies with
the following operating specifications.
Failure to do so may reduce the
effectiveness of the system and will void
the warranty. Consult your local water
treatment utility or a certified water
testing lab to determine the quality of your
water.
WARNING: Do not use with water that is
microbiologically unsafe or of unknown
quality without adequate disinfection
before or after the system. The Everpure
Conserv
LT-S Processor will not protect
®
against disease-causing bacteria or
remove harmless, naturally-occurring
bacteria.
WARNING: The Conserv LT-S Processor contains
replaceable components that are critical to
the efficiency of the system. Replacement
of the reverse osmosis component should
be with one of identical specifications, as
defined by the manufacturer, to assure the
same efficiency and contaminant reduction
performance.
WARNING: The Conserv LT-S Processor contains filter
cartridges and an RO membrane cartridge
included with the system that have limited
service lives. Product water should be
tested periodically to verify that the
Processor is working properly.
WARNING: The Conserv LT-S Processor shall only be
used for arsenic reduction on chlorinated
water supplies containing detectable
residual free chlorine at the system inlet.
Water systems using an in-line chlorinator
should provide one (1) minute of chlorine
contact time before the unit.
CAUTION: The Conserv LT-S Processor must be
protected against freezing which can
cause the filter housing to crack, resulting
in water leakage. Do not use electrical
heating tape or propane torch on this unit.
CAUTION: Make certain the unit is firmly attached to
wall to prevent it from falling and possibly
becoming damaged.
NOTE: Substances listed as reduced are not
necessarily in your water. The Processor must
be maintained according to manufacturer's
instructions, including replacement of filter
cartridges.
NOTE: Your water must be within required limits
for satisfactory operation. If not, the RO
membrane cartridge's life may be shortened
and your warranty will be voided (see

Operating Specifications).

NOTE: Install on cold water line only.
EVERPURE
CONSERV
®
®
LT-S HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE
®
NOTE: Do not install where system will be exposed to
direct sunlight.
NOTE: Make certain that installation complies with all
state and local laws and regulations.
NOTE: Use only plumbers tape without adhesive
backing to seal joints. Do not use pipe
compound ("pipe dope"), sticks, or similar
compounds with this unit; they contain
petroleum derivatives which can cause
crazing and cracking of the plastic in the filter
housing.
NOTE: Use only soap and water to clean components.
NOTE: Do not use aerosol sprays (bug spray, cleaning
fluids, etc.) near the Conserv LT-S Processor.
They contain organic solvents which can cause
crazing and cracking of the plastic in the filter
housing.
NOTE: During extended periods of non-use, turn OFF
the water supply to the unit and remove the
cartridges. Place the cartridges in a sealed
plastic bag. Store them in a refrigerator for
future use. When restarting the unit, the
cartridges are reinstalled and flushed per
instructions.
OPERATING SPECIFICATIONS
WARNING: Before installing the Processor, make
certain your water supply complies with
the following operating specifications.
Failure to do so may reduce the
effectiveness of the system and will void
the warranty. Consult your local water
treatment utility or a certified water
testing lab to determine the quality of
your water.
Inlet Temperature:
Dynamic Operating
Pressure:
Maximum Static
Pressure
Inlet Total Dissolved
Solids:
Sulfide, Iron and
Manganese:
Water Supply pH Limits:
Turbidity:
For cold water use only.
32 - 100°F (0 - 37.7°C)
40 - 85 psi (2.7 - 5.8 bar, 0.27 - 0.58
MPa), non-shock
125 psi (8.6 bar, 0.86 MPa)
1,000 ppm maximum
Less than 0.1 ppm
4 to 11
1.0 NTU maximum
3