Limited Flow at the Application Equipment Valve
1. Turn OFF water supply to processor.
2. OPEN the application valve to turn on flow.
3. Unscrew the blue cap on the side of the Storage Tank to
expose air valve. Use a small air compressor or bicycle
pump to slowly add air to the storage tank. This will
force the water out of the storage tank through the valve.
Continue to slowly add air until water stops coming out
of the valve.
4. Turn OFF the application equipment valve.
5. Using an air pressure gauge, adjust the pressure in the
storage tank to 5-7 psi (0.34 bar, 0.034 MPa).
6. Replace the blue cap.
7. OPEN the incoming water valve until it comes to a stop.
Let the processor run one (1) to three (3) hours to fill the
tank. A full tank weighs approximately 32 lbs (14.5 kgs)
pounds. If performance has not improved, call
Technical Support.
Sudden Return of Taste and Odor
If shortly after complete servicing, noticeable taste and odors
return, contact Technical Support.
NOTES
If you are experiencing a problem not listed in this manual,
shut OFF the water supply and CLOSE the tank valve. Call
Technical Support.
Check for compliance with state and local laws and
regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
For installations in Massachusetts, the Commonwealth of
Massachusetts Plumbing Code 248 CMR shall be adhered
to. Consult your licensed plumber for installation of the
system. This system and its installation must comply with
state and local regulations.
Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Substances that may be reduced are not necessarily in your
water. Filter must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
The efficiency rating for this system is 56.31%. Efficiency
rating means the percentage of the influent water to the
system that is available to the user as reverse osmosis
treated water under operating conditions that approximate
typical daily usage.
The tested recovery rating is 63.02%. Recovery rating means
the percentage of the influent water to the membrane portion
of the system that is available to the user as reverse osmosis
treated water when the system is operated without a storage
tank or when the storage tank is bypassed.
EVERPURE
CONSERV
®
LT-S HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE
®
Daily Production Rate: 70 gpd (265 Lpd).
This reverse osmosis system contains a replaceable
component critical to the efficiency of the system.
Replacement of the reverse osmosis component should
be with one of identical specifications, as defined by the
manufacturer, to ensure the same efficiency and contaminant
reduction performance.

REPLACEMENT PARTS

Contact your local Pentair
®
cartridges or system replacement parts.
Description
GRO-75EN RO Membrane Cartridge
4FC5 Filter Cartridge
4CC Mineral Cartridge
Storage Tank
TDS Meter
Port Plug
Waste Water Restrictor
Conserv LT-S Cartridge Kit
Conserv LT-S Tested and Certified by NSF
International against NSF/ANSI 58 for
the reduction of claims specified on the
Performance Data Sheet and at NSF.org.
Water Treatment
Appliance - E359339
Everpure Dealer for filter
Part Number
4002575
EV9693-21
EV9627-45
EV3146-98
EV3125-98
EV3108-76