Available languages

3 Attaching the Dome
Casing
1
1
Aligning the two screw holes on the
slit cover with the two slit cover
screws on the angle adjuster bracket,
put the slit cover back on. Turn the slit
cover to set it in place, and tighten the
slit cover screws.
2
Align the three screw holes on the
dome casing with those on the unit
casing.
3
Insert the three dome casing screws
into the screw holes and tighten them
with the wrench supplied to secure the
dome casing and the unit casing.

Replacing the Lens

Applicable lens (CS-mount lens)
Contact your Sony dealer for information on
applicable lenses.
2
Attaching a lens
1
2
3
4
2
1
4
Remove the lens plug.
Turn the lens counterclockwise to
remove it.
Notes
• At first the lens may make idle turns
because of the slip mechanism. When
the lens stops, turn it in the same
direction (counterclockwise) again
and remove it from the camera.
• Be careful not to damage the lens plug
or cable when removing the lens.
Put a lens on the mounting position
and turn the lens clockwise. When the
lens stops, turn it again in the same
direction (clockwise) to fix the lens in
place.
Insert the lens plug.