Introduction; General Information; Hazard Identification Information; Receiving Instructions - McQuay HI-F5 Installation And Maintenance Manual

Steam coils
Hide thumbs Also See for HI-F5:
Table of Contents

Advertisement

General Information

Introduction

These are general guidelines for the installation, operation and
maintenance of McQuay steam heating. They may have to be
tailored to meet the specific requirements of any one job. An
experienced installation company or fully trained personnel
should perform the installation and maintenance of any coil.

Hazard Identification Information

Dangers indicate a hazardous situation which will result in
death or serious injury if not avoided.
Warnings indicate potentially hazardous situations, which can
result in property damage, severe personal injury, or death if
not avoided.
Cautions indicate potentially hazardous situations, which can
result in personal injury or equipment damage if not avoided.

Receiving Instructions

Coils should be inspected for shipping damage upon
1
receipt. The freight bill should also be checked against
items received for complete delivery.
Damaged and/or missing items should be noted on the
2
carrier's freight bill and signed by the driver.
Figure 1: Coil Types
5R 5T
McQuay IM 901
DANGER
WARNING
CAUTION
5J 5G
Coils are factory tested at 315 psig (minimum air pressure)
3
while submersed in water.
For additional assistance, contact your local McQuay sales
4
representative.

Coil Types

Distributing

McQuay models JA, RA and DA jet-tube steam distributing
coils (Figure 1) are excellent for any general purpose heating
application. With the superior freeze resistance provided by
the tube-with-in-a-tube construction, it is ideal for low
temperature preheating and special process applications. The
construction features inner tubes with directional orifices to
aid in steam distribution and condensate removal. Model JA
offers same-end supply and return connections. Model RA
offers opposite-end supply and return connections. Model DA
offers dual-supply opposite-end connections for long coils that
see sub-freezing air temperatures. Models GA, TA and LA
utilize cupro-nickel, carbon steel and stainless steel tubing for
high-pressure construction.

Single Tube

McQuay model SA steam coils (Figure 1) are designed for
general purpose heating. The construction features a single
tube design with opposite-end supply and return connections.
A perforated baffle located directly behind the supply
connection insures proper steam distribution. Model HA
utilizes cupro-nickel, carbon steel and stainless steel tubing for
high-pressure construction.
5S 5H
Introduction
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-f5Hi-f8

Table of Contents