ALARM & PROGRAMMING FUNCTIONS
PROLONGED DOOR OPEN (PDO)
There are connections on the control unit to allow the monitoring of the door open
status. PDO is the amount of time the door may be open before triggering an
audible alarm from the control unit. This may be from 0 to 99 seconds. If set to
zero PDO sensing for that channel is disabled.
Enter Programming
 6 5 4 3 2 1
code
 3
Select Menu 3,
PDO Time
Enter new value
1 5
Press # to finish
Press  to
#
select a new
menu function.
Programming PDO Time
Pressing 7 and 8 together will mute the integral PDO alarm sounder. This does
not affect the PDO alarm output. The PDO will however re sound on the next
alarm occurrence. To disable the PDO sound and output permanently, program
the PDO time to zero.