Download Print this page
Hide thumbs Also See for STOR-96-G-W-1RH:

Advertisement

Quick Links

S
S
TORAGE
HED MODELS
Introduction............................ ...................... 1
Assembly Instructions STOR-96-G-W-1RH ............ 2
Assembly Instructions STOR-912-G-W-1RH............8
I
N
, W
MPORTANT
OTES
Ensure that all employees understand and follow these instructions.
Failure to read and understand this owner's manual before using or
servicing constitutes a misuse of the product. All persons who will
install, use, or care for this product must be familiar with this material.
Ensure that all information / safety / warning labels stay in place and are
o
legible.
Do not perform any modifications to the unit without the manufacturer's
approval. Failure to receive authorization for changes to the equipment
could void the warranty.
Maintenance and repairs are to be done only by personnel qualified to
perform the required work. Consideration will not be given for warranty
repair charges without prior written authorization by the manufacturer.
STOR-96-G-W-1RH
______________________________
STOR-96 and 912-G-W-1RH 0311
: STOR-96-G-W-1RH & STOR-912-G-W-1RH
S
I
ARNINGS AND
AFETY
STOR-912-G-W-1RH
STOR-96-G-W-1RH Exploded Parts Diagram & parts
List.......................................................... 17
STOR-912-G-W-1RH Exploded Parts Diagram & Parts
List........................................................... 18-19
NSTRUCTIONS
O
'
WNER
M
ANUAL
R
I
ECEIVING
NSTRUCTIONS
It is possible that this product
could
incur
damage
transit.
Inspect the unit closely when
it arrives. If you see evidence
of damage or rough handling to
either the packaging or to the
product
when
it
is
unloaded, immediately make a
note of it on the Bill Of Lading!
It
is
important
that
remove the product's packaging
upon its arrival to ensure that
there is no concealed damage
or to enable a timely claim with
the carrier for freight damage.
Also verify that the product
and its specifications are as
ordered.
T
R
OOLS
EQUIRED
-7/16" socket or wrench
-1/2" socket or wrench
-5/16" nut driver for drill
-Level
-Eye/Hand protection advised
Note – At least two people
required
to
assemble
product; three suggested
Page 1 of 20
S
during
being
you
this

Advertisement

loading

Summary of Contents for Vestil STOR-96-G-W-1RH

  • Page 1 STOR-96 and 912-G-W-1RH 0311 ’ WNER ANUAL : STOR-96-G-W-1RH & STOR-912-G-W-1RH TORAGE HED MODELS Introduction………………………. ……………….… 1 STOR-96-G-W-1RH Exploded Parts Diagram & parts Assembly Instructions STOR-96-G-W-1RH .……….. 2 List…………………………………………….…… 17 Assembly Instructions STOR-912-G-W-1RH……...…8 STOR-912-G-W-1RH Exploded Parts Diagram & Parts List………………………………………………..18-19 MPORTANT OTES...
  • Page 2 Review the bill of materials located on page 17. Unpack all materials and verify quantities before starting. Consult the factory in the event there are any questions or problems at the time of installation, or for information regarding optional features not covered by the owner’s manual. --------------------------------------------------------------------------------------- STOR-96-G-W-1RH INGLE TORAGE NIT MODEL Place wooden floor on clean and level surface.
  • Page 3 STOR-96 and 912-G-W-1RH 0311 Secure back wall to the wooden floor using the ¼” X 2” lag bolts into the 5 predrilled holes. Continue holding back wall until at least two walls are connected together and lagged to the wooden floor. Install lockstrip to both vertical ends of back wall.
  • Page 4 STOR-96 and 912-G-W-1RH 0311 Install 2 side wall using foot to hold bottom of wall while inserting into lockstrip. Secure both side walls to the wooden floor using ¼” X 2” lag bolts into the 5 predrilled holes located at the bottom of each side wall.
  • Page 5 STOR-96 and 912-G-W-1RH 0311 Place roof on top of the storage unit walls and simply pull it down into the channels until it bottoms out. Secure roof to the front and back walls with 8pc 1” long self-tapping screws. (4 pcs. per wall) These holes are not predrilled.
  • Page 6 ¼”nut per hinge. Align and tighten. Hinge plates must be inside building as shown. Install locking bar. Use 6pc of ¼”X 1” carriage bolts, 6pc 5/16” washers, 6pc ¼” washers and 6pc ¼” nuts as shown above. Rounded head carriage bolts will outside building. Copyright 2011 Vestil Mfg. Co. Page 6 of 20...
  • Page 7 STOR-96 and 912-G-W-1RH 0311 Completed Unit Page 7 of 20...
  • Page 8 STOR-96 and 912-G-W-1RH 0311 STOR-912-G-W-1RH OUBLE TORAGE NIT MODEL Install joint, 2”x 4”s, to 9 foot side of each wooden floor, ¾” down from top using 6pc – 3” long wood screws, as evenly spaced as possible per side. Place wooden floors with 2”X4” joints together on a level surface and position pre-cut spacers as shown. Using 20pc of 2”...
  • Page 9 STOR-96 and 912-G-W-1RH 0311 Install Face Joint to the center fo the two joined wooden floors using 2pc of ¼” X 2” lag bolts – one bolt per face joint on each side for the wooden floors. Begin assembly with wooden floors on clean level surface. Position back wall as shown above.
  • Page 10 STOR-96 and 912-G-W-1RH 0311 Secure back wall to the wooden floor using ¼”X 2” lag bolts into the 5 predrilled holes. Continue holding back wall until at least two walls are connected together and lagged to the wooden floor. Install lockstrip to both vertical ends of back wall. Install one side wall by inserting into the lockstrip just installed on the back wall vertical end.
  • Page 11 STOR-96 and 912-G-W-1RH 0311 Install 2 sidewall using foot to hold bottom of the side wall while inserting it into lockstrip on opposite end of the back wall. Secure both side walls to the wooden floor using ¼” X 2” lag bolts into the 5 predrilled holes on each side. Install lockstrip on end of side wall and then install Side Fill Panel, as seen above on right hand side (see step 13 for installation) Page 11 of 20...
  • Page 12 5 predrilled holes at the bottom of each wall. Install lockstrips (2) on each side wall, then insert front wall into lockstrips. Install 5pc of ¼”X2”lag bolts into predrilled holes to secure front wall to the wooden floor. Copyright 2011 Vestil Mfg. Co. Page 12 of 20...
  • Page 13 STOR-96 and 912-G-W-1RH 0311 Place roof on top of the storage unit walls and simply pull it down into the channels until it bottoms out. Repeat with second roof piece. Roof panel Roof panel Install the formed roof angle piece (16) between the roof panels; then install the roof seam cover plate (15) on top of the angle piece.
  • Page 14 STOR-96 and 912-G-W-1RH 0311 Secure roof to front and back walls with 16pc 1” long self-tapping screws.(4pc per wall) These holes are not predrilled. Space screws evenly. Install two door hinges on front wall using 4pc hex headed bolts, 5/16”X 1” and 2pc threaded plates. (See following illustrations) Install hinges on front wall using threaded plates.
  • Page 15 STOR-96 and 912-G-W-1RH 0311 Fasten door to hinge using reinforcing hinge plates (2) and 6 pc -¼”carriage bolt, ¼” lock washer and ¼”nut per hinge. Align and tighten. Hinge plates must be inside door as shown. Install locking bar. Use carriage bolts (6¼in. x 1in.), 6 5/16” washers, 6pc ¼” washers and 6pc ¼” nuts as shown above.
  • Page 16 STOR-96 and 912-G-W-1RH 0311 Fully assembled unit. Page 16 of 20...
  • Page 17 STOR-96 and 912-G-W-1RH 0311 STOR-96-G-W-1RH E XPLODED ARTS IAGRAM Item No. Part No. Description Quantity 41-514-017 Wood base frame assembly 41-514-012 Door frame assembly 41-514-013 Side wall frame assembly 41-514-015 Door assembly 41-514-014 Rear wall frame assembly 41-514-016 Roof frame assembly...
  • Page 18 STOR-96 and 912-G-W-1RH 0311 STOR-912-G-W-1RH E XPLODED ARTS IAGRAM Page 18 of 20...
  • Page 19 STOR-96 and 912-G-W-1RH 0311 STOR-912-G-W-1RH P ARTS LIST Item No. Part No. Description Quantity 41-014-030 Formed floor seam cover plate 41-514-013 Side wall frame assembly 41-514-014 Rear wall frame assembly 41-514-012 Door frame assembly 41-514-015 Door 41-537-001 Lock/latch bar assembly ¼...
  • Page 20 How long is the warranty period? The warranty period is 90 days, and the period begins on the date when Vestil ships the product to the warrantee. If the product was purchased from an authorized distributor, the period began when the distributor shipped the product. Vestil may extend the warranty period for products shipped from authorized distributors by up to 30 days to account for shipping time.

This manual is also suitable for:

Stor-912-g-w-1rh