Hydrotek H-8000C Series Operation & Maintenance Manual

Hydrotek H-8000C Series Operation & Maintenance Manual

Flush valve
Hide thumbs Also See for H-8000C Series:

Advertisement

HYDROTEK INTERNATIONAL, INC.
957 N. Pennsylvania Avenue, Winter Park, FL 32789 800-922-9883 Fax: 407-647-0471
OPERATION & MAINTENANCE MANUAL
HYDROTEK MODEL #H-8000C FLUSH VALVE
TECHNICAL SERVICES MANAGER: MICHAEL HU
EMAIL: mike@hydrotekintl.com
PHONE: 800-922-9883
FAX: 407-647-0400

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H-8000C Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Hydrotek H-8000C Series

  • Page 1 HYDROTEK INTERNATIONAL, INC. 957 N. Pennsylvania Avenue, Winter Park, FL 32789 800-922-9883 Fax: 407-647-0471 OPERATION & MAINTENANCE MANUAL HYDROTEK MODEL #H-8000C FLUSH VALVE TECHNICAL SERVICES MANAGER: MICHAEL HU EMAIL: mike@hydrotekintl.com PHONE: 800-922-9883 FAX: 407-647-0400...
  • Page 2 1-112" HB8RFKC Retrofit Flush Valve Models: STANDARD PACKAGE iNCLUDES: * HB8RFKC-C Hydrotek Retrofit battery-powered closet flush valve. Unit bolts to Sloan or Zurn stop valve and flush tube. * HB8RFK-U Same as above, but for urinals EXPOSED FLUSH VALVE MODELS * HB8RFKC-CD Hydrotek Retrofit battery-powered closet flush vavle.
  • Page 3 INSTALLATION ROUGH-IN TEMPLATE HYDROTEK Model # H-8000C Flush Valve 1-1/2" IMA. HOLE THROUGH WALL...
  • Page 4 8. TEST: Stand in front of the Valve and a red light should come on. After 4 seconds and steps away, the valve should flush automatically. If not, refer to the Trouble Shooting Guide. 9. Flush Valves are pre-adjusted at the Factory. If minor adjustment is needed, call Hydrotek for further details 1-800-922-9883.
  • Page 5: Optional Accessory

    HYDROTEK INTERNATIONAL, INC. 800-922-9883 Fax: 407-647-0471 HC-O1O Multi-Unit Power Adapter OPTIONAL ACCESSORY TOP VIEW WARNING: DO NOT TOUCH input: I2OVAC LEADS TOGETHER WHILE UNIT IS PLUGGED UNIT WILL FAIL AND WARRANTY W1LL BE VOIDED 24" IILLI 711111 -"4 20" Mounting Bracket...
  • Page 6 AC POWERED EXPOSED TYPE FLUSH VALVE H-8000C Closet or Urinal 1. Top cap cover. Vacuum breaker. 2. Control modulePCB. Lock nut. 3. Stop valve. Tailpiece. 4. Sensor eye. Top spud. 5. Retainer ring. Set screw. 0-Ring. DC power connector. 7. Slip joint nut. AC input tube.
  • Page 7 Manual push button is sticking. If water is leaking through, then the solenoid valve is dirty. Follow same procedures as above for remedies. IMPORTANT:1 Periodical maintenance is required for a smooth and trouble-free operation of the flush valve. For more detailed procedures for above remedies, call Hydrotek at I -800-922-9883. 100200...
  • Page 9: Switch Adjustments

    HYDROTEK AUTOMATIC FLUSH VALVE Dip Switch Settings Flushing Volume Time Closet or Urinal: Gallons Per Flush Sw I Sw 2 Sw 3 Sw 4 Flush Time I SEC Urinal 2SEC Closet 3 SEC 4 SEC 5 SEC 6 SEC 7 SEC...
  • Page 10: Control Module

    CONTROL MODULE Legend: (1) = Solenoid Pin Receptor (2) = Control Cable (Sensor Eye) Pin Receptor (3) = AC Input Pin Receptor (4) = DC Input Pin Receptor (5) = Electro-Mechanical Push Button Pin Receptor (6) = AC/DC Selector Switch (7) = DC Input Pin Receptor (8) = Dip Switches (9) = Reset Button...

This manual is also suitable for:

Hb-8000c series

Table of Contents