• SPECIAL FUNCTION CONTROL CODES
CODE MODE
ACTIVATES
• The card supplied with the R-2001D and the applique
Enables automatic
inside the front-panel cover show the special function
40
DVM
codes. Table 3-3 lists the special function control
.::.
DVM ranging
(default~._
codes grouped according to the first digit of the code
state)
and then grouped by function type.
41
DVM
Enables 1.0 V DVM range
• A master reset code
a
(zero) causes all function types
42
DVM
Enables 10 V DVM range
to revert to the default states listed in table 3-3.
• To obtain a CRT display of all activated special
43
DVM
Enables 100V DVM range
functions, simultaneously depress both keypad cur-
44
DVM
Enables 300V DVM range
sor keys twice. The screen will automatically return
50
Modulation Meter Enables automatic
to standard operation after 10 to 15 seconds.
modulation ranging
CODE MODE
ACTIVATES
(default state)
51
Modulation Meter Enables 10 KHz range
0
Master Reset
Clears all special functions
52
Modulation Meter Enables 100 KHz range
(default state)
10
Encode/ Decode
Clears all IX E/D special
60
Counter
Auto counter resolution
functions (default state)
(default state)
11
Encode/Decode
Baseband
61
Counter
0.1
Hz resolution
12
Encode/Decode
Decode only
62
Counter
1 Hz resolution
13
Encode/Decode
Encode Only
63
Counter
10 Hz resolution
64
Counter
100 Hz resolution
20
Monitor
Clears all 2X monitor
65
Counter
1 KHz resolution
special functions (default
70 . System Control
Sets factory control states
state)
(default state)
21
Monitor
Enables 300 Hz LPFL
71
System Control
Sets the current state
22
Monitor
Enables 3 KHz LPFL
as the power-on state
23
Monitor
Enables 20 KHz LPFL
72
System Control
Initiates a system self test
24
Monitor
Enables 5 Hz HPFL
73
System Control
Disables the automatic
25
Monitor
Enables 300 Hz HPFL
switching to monitor mode
if the input signal is over
26
Monitor
Enables 3 KHz HPFL
O.l.W.
30
Frequency
Clears all frequency 3X
74
System Control
Mutes speaker during GEN
special functions (default
77XY System Control
Sets the last XY in RF
state)
memory presets as duplex
31
Frequency
Enables direct frequency
7700
System Control
Resets from duplex to
readout (10 Hz resolution)
simplex (default state)
32
Frequency
Enables direct frequency
78XYZ System Control
Sets deviation audible
readout (l Hz resolution)
tAo
N,
7'i
50
alarm to XY.Z KHz
c
1:1
-I
33XY Frequency
Enables scan lock from
78000
System Control
Disables audible alarm
XOO MHz to YOO MHz
(default state)
3300
Frequency
Enables full-band
79
System Control
Resets nonvolatile memory
scan lock
34XY
Frequency
Enables scan latch from
99
Software Version Shows P /N of resident
XOO MHz to YOO MHz
software version
3400
Frequency
Enables full-band scan
TABLE 3-3. SPECIAL FUNCTION CONTROL CODES
latch
3-7