Bandpass Cavity Tuning - Motorola R-2001D Operator's Manual

Communications system analyzers
Table of Contents

Advertisement

BANDPASS CAVITY TUNING
Use this procedure to peak-tune bandpass cavities, duplexers, crystal filters and other bandpass devices. Tune the band-
pass to center frequency. After tuning, use normal gain or loss measuring techniques to measure insertion loss.
1. Connect the Analyzer to the device under
test, as shown in figure 4-20. When tuning a single cavity, connect the RF
In/Out to the cavity's output connector. When tuning a bandpass duplexer, connect the RF In/Out
to
the duplexer's
antenna port.
2. Set DISPLAY to Duplex Gen, FUNCTION switch to Generate, and attenuator to -lOdb.
3. Change the FUNCTION switch to Monitor. Enter pass frequency on the display. Set the offset to 0 MHz.
4. Change DISPLAY to Spectrum Analyzer. Set Dispr/Sweep control fully clockwise to 10 MHz. Turn the Duplex
Generator on.
5. Tune the cavity, or both cavities in the duplexer leg, to a peak indication on the display's center graticule. The single
cavity is ready for service.
6. For duplexer tuning, move the output cable from the Duplex Oen Output connector to the duplexer's other end.
Repeat steps 2 through 4. Put the duplexer into service. Check the duplexer for insertion loss according to its
specifications.
4-36
"----"

Hide quick links: