Measurements And Adjustments; Voltage Chart Of A-Board; Voltage Chart Of P-Board - Panasonic TX-LR32B6 Service Manual

Table of Contents

Advertisement

TX-LR32B6

8 Measurements and Adjustments

8.1.

Voltage chart of A-board

Set A-Board to a dummy set and check the satisfaction with the specified voltage as following table.
8.2.

Voltage chart of P-board

Set P-Board to a dummy load and check the satisfaction with the specified voltage as following table.
Power Supply Name
STB5.3V
P15V
GND
P_STMGP103
Output
Test Point
5.3V
TP7501
16V
TP7410/ TP7411/ TP7412
24V
TP7511/ TP7512
TP No.
Voltage (V)
TP2017
5.3V ± 2%
TP2013
16V ± 2%
TP2015
0V
TP8924
0V
Specification
Operate
5.3 ± 0.20V
15.5 ± 0.8 V
24V ± 1.2 V
24
STBY
5.3 ± 0.20V
-
-

Hide quick links: