Error Messages - Baumuller BUS 6 VC Manual

Digital control buc v-controller
Table of Contents

Advertisement

Maintenance
8.2

Error Messages

In the event of an error, parameter M error code (P124) indicates the appropriate error code. This error
is acknowledged when bit Reset disturbance in M control word (P120) is set from 0 to 1. If there is more
than one error, the system shows the next one immediately after acknowledgement.
!
Drive Manager Function Module (Error ID 00xx)
Error ID
Error Text
0001
BASS protocol timeout
hex
0003
Dual-Port RAM time-
hex
out (cyclical data)
0004
Dual-Port RAM time-
hex
out (working data)
0005
System boot procedure
hex
0010
Error switch (program
hex
error)
92
Meaning
The communications source set in
P124 has not responded for longer
than the timeout set in P128.
An error was determined while
reading the boot data set from the
EEPROM. You can get more infor-
mation about the type of error by
referring to parameter DSM Mes-
sage (P192).
This disturbance usually occurs if
you replaced the controller firm-
ware with firmware that is incom-
patible.
Only for software development
5.03047.01
Error reaction
Error reaction can be
set in P189
Inhibit pulses imme-
diately
Inhibit pulses imme-
diately
Baumüller Nürnberg Electronic GmbH & Co. KG
Remedy
Check communications
(cables, daughterboard,
etc.)
You should carefully
check the data set in the
controller's RAM and then
program it in the EE-
PROM as the boot data
set.
V-Controller (BUS 6 VC)