Cable Position Numbers; Ssb Identification - Philips 22PFT4031/12 Service Manual

Tpn16.3e la chassis
Table of Contents

Advertisement

Also the virgin bit is to be set. To set all this, you can use the
"NVM editor" and "Dealer options" items in SAM (do not forget
to "store").
After a repaired SSB has been mounted in the set (set repair
on board level), the type number (CTN) and production code of
the TV has to be set according to the type plate of the set. For
this, you can use the NVM editor in SAM.
In case of a display replacement, reset the "Operation hours
display" to "0", or to the operation hours of the replacement
display.
Remark:
- After the NVM has been replaced, go to SAM and scroll to the
<Reload MAC address> (see figure 1*).
- Select the item and press <OK> on the RC.
6.5.1
Reset of Repaired SSB
Instruction
After NVM replacement, reload MAC address via SAM
menu.This ensures the correct MAC address to be available in
CSM for future repair actions.
Way of working:
After the NVM has been replaced, go to SAM and scroll to
the <Reload MAC address> .
Select the item and press <OK> on the RC.
Notes:
Only applicable to all related models that are "Smart TV
level 0"enabled (only YouTube access). For models
without internet connection feature, no action is needed.
HDCP keys are located in the NVM.
New NVM EEPROMs are shipped with pre-loaded HDCP keys.
6.5.2

SSB Identification

SSB's of this chassis are identified by a "715" code on the SSB.
715Axxxx-Nnn-MMM-OOOO
715 main category, Printed Wiring Board
Axxxx sub category, sequential coding number
Nnn Version code
N Development number
nn Production number
MMM Mounting variation code
OOOO Optional variation code
Make sure when replacing an SSB the SSB identification codes
match the replacement panel.
6.6

Cable position numbers

In this chassis, the cable position numbers can be defined via
the rule that the number is always starting with an "E" followed
by the connector number of the current sourcing board. The
order is always seen from where the power initiates from. So
from PSU to SSB, from SSB to IR/LED panel, from IR/LED
panel to keyboard control panel. For example, a cable from the
PSU connector CN902 to the SSB connector CN701, will have
the position number ECN902.
Alignments
back to
div. table
TPN16.3E LA
6.
EN 31
2016-Oct-28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents