PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Page 2
Microsemi, a wholly owned subsidiary of Microchip Technology Inc. (Nasdaq: MCHP), offers a comprehensive portfolio of semiconductor and system solutions for aerospace & defense, communications, data center and industrial markets.
Does nothing. • Press button for 2-10 seconds and release: Reset switch by software (no configuration change). • Press button for more than 10 seconds and release: Restore unit to factory default. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Run the serial communication application as PuTTY https://www.putty.org/ • Select the serial COM index allocated for SiliconLabs CP210x USB to UART driver • Set Baud rate to 115200 • One Stop bit • No flow control Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
SFP interface – SFP interface supports the following type of SFP modules 100M/1000M fiber SFP transvers 100M/1000M Copper SFP transvers Single/Multi mode SFP fiber transvers NOTE: There is no support for SFP+ transvers Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
2. The Home icon at the top-right redirects to the main web page as shown in figure 2-1. 3. Pressing on the Refresh button will refresh the current page. Please note that the Refresh button will only be available on selected web pages. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Startup Configuration profile – Unit configuration to be used whenever power is applied to the unit, or after each unit software reset. • Default Configuration profile – Unit configuration as it was released from the factory before the user made any changes. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
From the Web - press on Save running config followed by pressing on Save Configuration. Figure 2-2: Save unit configuration • From CLI - type over the USB serial interface/Telnet/SSH: “copy running-config startup- config”. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
PoE power usage, overall PoE power consumption and unit temperature. Hovering with the mouse above the RJ45 connector will display the port network status. Left mouse click on the RJ45 connector will open a detailed port network traffic report page. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Table 3-3: SFP jack images of both Ethernet link and link status. NOTE: Some SFP modules may fail to report as being inserted whenever their Link is Down (applicable to state: SFP-Inserted, Link-Down/Disabled). Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Ethernet port is enabled, link is up, half duplex, 100Mbit/seconds 100Mbs FDX Ethernet port is enabled, link is up, full duplex, 100Mbit/seconds 1Gbps FDX Ethernet port is enabled, link is up, full duplex, 1000Mbit/seconds Table 3-4: network S Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Page 19
(PoE disabled) for around 5-8 seconds, followed by restoring POE power (PoE Enabled). NOTE: Pressing on Reset PoE will open a dialog box reporting that PoE power will be turned Off and back to On, allowing the user to cancel this action. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Figure 3-4: Port Statistics Overview 3.2.1 Port Statistics Overview Port Statistics Overview - displays incremental counters for the number of received, transmitted, errors, drops and filtered packets for each one of the eleven ports. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Linux packages that are part of the software making it all work. Figure 3-6: System Information Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Report static and dynamic MAC address learned by the Switch, and from which Ethernet port IP Status Summary of all the IPv4, IPv6 address in use Routing Info Summary of all route entries in use Table 4-2: network - View sub pages Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Maximum Set the maximum supported Ethernet frame size (including FCS). Frame Configure Possible values range from 1518-9600. Size Table 4-3: Ethernet port Configuration/View options Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
You only need to configure VLAN-ID, IPv4 address, and IPv4 mask length (for example 24 is equivalent to 255.255.255.0) NOTE: To delete an IP address raw, select the Delete checkbox and press Save Figure 4-2: Static IPv4 Address Configuration. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
The IP routes section controls which default gateway to use when an IP address should be sent by the unit management interface to another network outside of the unit local LAN. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Figure 4-5: NTP Server configuration Network - Configuration – Time Zone This page is used to configure the unit’s local time zone and daylight saving. 4.4.1 Time Zone Configuration Figure 4-6: Time Zone Configuration Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
VLAN inside the MAC learning table. If it is found, then the packet will be forwarded to the specified port; otherwise the packet is flooded to all ports on the same VLAN. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Set the maximum time in seconds in which a source MAC address may remain in the Switch MAC table without receiving another packet with the same source MAC address from the same port. 4.6.2 MAC Table Learning Figure 4-11: MAC Table Learning Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
MAC. The Switch MAC table will not update the source port from which the packet was received. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
This page displays the various dynamic addresses that can be used to manage the unit, the IPv6 routes and the neighbor cache (ARP cache) status. Figure 4-15: View unit in use IP address Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
This page displays the routing option used by the unit for communicating with other IP-based network devices located on other networks. The routing information may be based on user static configuration, or by DHCP. Figure 4-16: View unit Routing Information Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Delete: Delete the certificate being used by the Web Server. Since HTTPS cannot operate without a certificate, this option can be executed only when the Web Server is configured as HTTP Web Server. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
2 authentication service will be used instead, and the same for 3 in case both the 1 and the 2 authentication services are unreachable. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
The user can configure that any login/logout or any command being typed will be reported to TACACS+ Accounting Server (the same used for remote user authentication). Same for any CLI command typed by the user. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Access Control List is enabled. This report may help, for example, to identify an external user trying to hack the unit by reporting the number of discarded packets, etc. Figure 5-7: View ACL Statistics Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
The VLAN configuration page consists of a global section and per port VLAN configuration. NOTE: NOTE – The next section contains several VLAN configuration examples which should make VLAN configuration understanding easier. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
VLAN-ID #0 used typically by VoIP system to mark VoIP priority packets Priority Tag Native VLAN Packet with no VLAN tagging C-Tag Customer VLAN-ID tag. Service provider encapsulation of original customer C-Tag VLAN-ID S-Tag with another VLAN-ID named S-Tag. Double Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Page 38
5, will be transmitted untagged. VLAN=5 Egress Tag configuration parameter = Tag All Rx native VLAN (untagged packets) is discarded. Rx VLAN priority tag (VLAN-0) is discarded. Tx all packets as VLAN tagged Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Page 39
If a frame is untagged or priority tagged, the frame gets classified. - Port Type= Rx path: C-Port Rx VLAN-2 (an example), Tx to another Trunk port as VLAN-2, also any - Port Access Port VLAN-2. VLAN=5 Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Ethertype for Custom S-ports – TPID value (specified in hexadecimal) used for Q-in-Q 802.1ad double VLAN tagging as described in the image bellow. The default value is 0x88A8, and it applies to all ports whose Port Type is set to S-Custom-Port. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Frames classified to the Port VLAN do not get C-tagged on egress. Egress tagging can be changed to tag all frames, in which case only tagged frames are accepted on ingress. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Page 42
Tagged and Untagged: Both tagged and untagged frames are accepted. • Tagged Only: Only tagged frames are accepted on ingress. Untagged frames are discarded. • Untagged Only: Only untagged frames are accepted on ingress. Tagged frames are discarded. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
VLANs. VLAN - View Members This page displays which VLAN-IDs are linked to which Switch Ethernet ports. Figure 6-6: VLAN Membership Status Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
VLAN VLAN – View Ports VLAN – View Ports This page displays a summary of all ports VLAN configuration Figure 6-7: VLAN Port Status for Combined users Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
PD and allocates Maximum-Power for each port accordingly. Poe-PD Maximum allocated PoE-BT PoE-AT PoE-AF Class Power [W] by the support Support Support Switch 15.4 (same as class-3) 15.4 Table 7-1: PoE maximum power[W] per PD advertised class Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Enable – Enable/Disable POE power. Please note that the Ethernet port will remain active even when PoE port is disabled. PoE Mode • 802.3BT: Powers only PoE-BT/PoE-AT/PoE-AF compliant PD (powered device) devices. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
PoE PD device was detected and power is delivered by the Switch to the PD device. (2Pair) However, the power is delivered on only two out of four Ethernet pairs of the RJ45 jack. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
PoE Priority – Displays the PoE priority as it was configured by the user. For a more detailed description please refer to the PoE Priority configuration description. PoE – Reports the PoE current [mA] consumed by the PoE PD device. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Transmit Hold Count - The number of BPDUs a bridge port can send per second. When exceeded, transmission of the next BPDU will be delayed. Valid values are in the range 1 to 10 BPDUs per second. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
The value of this flag is based on AdminEdge and AutoEdge fields. This flag is displayed as Edge in Monitor STP Detailed Bridge Status Spanning Tree. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
MSTI - The Bridge Instance. This is also a link to the STP Detailed Bridge Status as described below. Figure 8-4: View STP Detailed Bridge Status 8.4.1 STP Detailed Bridge Status • Bridge Instance - The Bridge instance - CIST, MST1, ... Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Uptime - The time since the bridge port was last initialized. Bridge ID -The Bridge ID of this Bridge instance. Root ID - The Bridge ID of the currently elected root bridge. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Port - The switch port number of the logical STP port. MSTP - The number of MSTP BPDUs received/transmitted on the port. RSTP - The number of RSTP BPDUs received/transmitted on the port. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Page 54
Spanning Tree - STP Spanning Tree - View - STP Port Statistics STP - The number of legacy STP Configuration BPDUs received/transmitted on the port. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
System Location - The physical location of this unit. The allowed string length is 0 to 255, and the allowed content is the ASCII characters from 32 to 126. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Configures SNMP community table used as part of SNMP Group Configuration. Entry index key is Community name. Delete - Check to delete the entry. It will be deleted during the next save. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Read View Name - The name of the MIB view defining the MIB objects for which this request may potentially read OiD values. Write View Name - The name of the MIB view defining the MIB objects for which this request may potentially set OiD new values. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
No privacy protocol. • DES: An optional flag to indicate that this user uses DES authentication protocol. • AES: An optional flag to indicate that this user uses AES authentication protocol. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
The first character must be an alpha character, and the first and last characters must not be a dot or a dash. Destination port - Indicates the SNMP trap UDP destination port. The default value should be UDP port 162. Valid UDP port range is 1~65535. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Community name field is just a reference to the Community secondsret password field • Modify/create two groups using SNMPv2c security model and link them to the community name created in the previous step. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
• Add to “ANMP Access Configuration” the group name from previous stage, with security Level of SNMPv3, and assign to it the desired read/write options Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
26 with the mentioned string will assign user privilege level number 1 out of 15 with no ability to do any changes inside the unit. • Configuring Free-Radius users.conf configuration file: Change users.conf as follows: username Cleartext-Password := "pass" Cisco-AVPair += "priv-lvl=15" Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Timeout - This optional setting overrides the global timeout value. Leaving it blank will use the global timeout value. • Retransmit - This optional setting overrides the global retransmit value. Leaving it blank will use the global retransmit value. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Change secondsret Key - Specify to change the secret key or not. When the checkbox is checked you can change the setting overrides the global key. Leaving it blank will use the global key. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
(backup) Radius-Server. The Server will be re-enabled after dead-time expires. NOTE: Dead state is applicable only when there is more than one RADIUS-server, and dead-time time value is greater than 0 Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
RADIUS packets that were received with unknown types from the server Unknown Types radiusAuthClientExtUnknownTypes on the authentication port and dropped. Packets RADIUS packets that were received radiusAuthClientExtPacketsDropped Dropped from the server on the authentication Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Page 67
Time authentication server. The granularity of this measurement is 100 ms. A value of 0 ms indicates that round-trip communication hasn’t been established with the server yet. Table 10-1: Packet Counters Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
(backup) Radius-Server. The Server will be re-enabled after dead-time expires. NOTE: Dead state is applicable only when there is more than one RADIUS-server, and dead-time time value is greater than 0. Table 10-2: Other Info Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
(re-)calculation when links with higher priority become available. Max Bundle - This parameter only applies to LACP-enabled groups. It determines the maximum number of active bundled LACP ports allowed in an aggregation. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Type - Type of the Aggregation group (Static or LACP). • Speed - Speed of the Aggregation group. • Configured ports - Configured member ports of the Aggregation group. • Aggregated ports - Aggregated member ports of the Aggregation group. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Lower number means greater priority. 11.5 Aggregation/LACP – LACP – View – System Status This Page provides a status overview for the system-level LACP information. Figure 11-4: View LACP System Status Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Aggregator, and the identity of the LAG is consistent with the System ID and operational Key information transmitted. • Collecting - Shows if collection of incoming frames on this link is enabled. • Distributing - Shows if distribution of outgoing frames on this link is enabled. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Distributing - Shows if distribution of outgoing frames on this link is enabled. • Defaulted - Shows if the partners Receive machine is using Defaulted Operational Partner information. • Expired - Shows if that the partners Receive machine is in the EXPIRED state. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
LACP Transmitted - Shows how many LACP frames have been sent from each port. • Discarded - Shows how many unknown or illegal LACP frames have been discarded at each port. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Interface - The name of the switch’s logical LLDP interface. • Mode - Select LLDP mode. Rx only: The switch will not send out LLDP information, but LLDP information from neighbor units is analyzed. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Page 76
Sys Capa - Optional TLV: When checked the "system capability" is included in LLDP information transmitted. • Mgmt Addr - Optional TLV: When checked the "management address" is included in LLDP information transmitted. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
• Management Address - The neighbor units address that is used for higher layer entities to assist discovery by the network management. This could for instance hold the neighbors IP address. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
LLDP frame is counted and discarded. This situation is known as "Too Many Neighbors" in the LLDP standard. LLDP frames require a new entry in the table when the Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Page 79
(age-out time). If no new LLDP frame is received within the age out time, the LLDP information is removed, and the Age-Out counter is incremented. • Clear - If checked, the counters for the specific interface are cleared when is pressed. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Example - Marking ports 1,2 will block any traffic from port 1 to reach to port 2 and vice versa. However, each one of them can communicate normally with ports 3-11 Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Port Isolation – Configure Port Isolation Figure 13-2: Port Isolation Configuration 13.2.2 Port Isolation - configuration parameters • Port Members - Select the ports that are not allowed to communicate with each other (isolated). Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Shutdown Port, Shutdown Port and Log or Log Only. • Tx Mode - Controls whether the port is actively generating loop protection PDUs, or whether it is just passively looking for looped PDUs. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
• Proxy Enabled - Enable IGMP Proxy. This feature can be used to avoid forwarding unnecessary join and leave messages to the router side. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
0.0.0.0 (not set) and no VLAN IPv4 management address – uses the first available IPv4 management address, and if there is no such IPv4 address, then uses 192.0.2.1 as default IPv4 source IP address. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
15.4.1 IGMP Snooping Group Information • VLAN ID - VLAN ID of the group. • Groups - Group address of the group displayed. • Port Members - Ports under this group. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Host Version - Current Working Host version. • Querier Status - Shows the Querier status as "ACTIVE" or "IDLE". "DISABLE" denotes the specific interface, which is administratively disabled. • Queries Transmitted - The number of Transmitted Queries. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Dynamic means the specific port is learnt to be a router port. Both denote the specific configured or learnt port as a router port. • Port - Switch port number. • Status - Indicates whether a specific port is a router port or not. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Multiple source ports can be mirrored to a single destination mirroring port • Destination - The destination port will receive a copy of the traffic from the all selected source ports. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Page 89
Port Mirroring Port Mirroring - General NOTE: MAC Table learning under network > Configuration > MAC - Table learning needs to be disabled on the destination port. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Figure 17-2: Maintenance – Download unit configuration This page allows you to download the unit configuration to your own laptop, desktop, etc. Before downloading the unit configuration, you must select which configuration should be downloaded. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Select the file to activate and click Activate Configuration. This will initiate the process of completely replacing the existing configuration with that of the selected file. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
For example, my-switch-software.mfi. After the software image is uploaded, a message is displayed that the firmware update is initiated. After about a minute or so, the software is updated and the switch restarts. Figure 17-4: Software Update – in progress indication Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
3 - The firmware version and date information may be empty for older firmware releases. This does not constitute an error. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
3. Type fis swap linux linux.bk to revert the Switch to the older software version. 4. Type reset to restart the Switch using the reverted software version. Figure 17-7: Recovering from endless reboot after software update Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Start from ID – the input field allows you to change the starting point in the SysLog table report. Clicking the button will update the displayed table starting from that or the closest next entry match. Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Packet Count - Determines the number of PING requests sent. The default value is 5. The valid range is 1-60. Pressing the Start button will initiate a series of pings as shown in the figure bellow. Figure 18-4: Ping in action Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Cross C - Abnormal cross-pair coupling with pair C Cross D - Abnormal cross-pair coupling with pair D Length: The length (in meters) of the cable pair. The resolution is 3 meters Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...
Diagnostics Diagnostics – View CPU Load 18.4 Diagnostics – View CPU Load This page shows the Switch CPU load. Figure 18-6: Switch CPU load Microsemi PDS-408G Web Management User Guide Ver. 1.0.1, 03-2019...