Alpha-InnoTec WWS 121 Operating Manual
Alpha-InnoTec WWS 121 Operating Manual

Alpha-InnoTec WWS 121 Operating Manual

Accessories for heat pumps, domestic/solar domestic hot water tank
Hide thumbs Also See for WWS 121:

Advertisement

Accessories for
heat pumps
Operating Manual
Domestic hot water tank
Solar domestic hot water tank
UK
83018600hUK – Translation of the original operating manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WWS 121 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alpha-InnoTec WWS 121

  • Page 1 Accessories for heat pumps Operating Manual Domestic hot water tank Solar domestic hot water tank 83018600hUK – Translation of the original operating manual...
  • Page 2: Please Read First

    Please read first Symbols This operating manual provides important information The following symbols are used in the operating on handling the unit. It is an integral part of the product manual. They have the following meaning: and must be stored so that it is accessible in the immediate vicinity of the unit.
  • Page 3: Table Of Contents

    Draining ..............9 Maintenance of the unit ..........5 Technical Data Disposal ..............5 WWS 121 – WWS 202 ........10 WWSB 202 ............11 WWS 303.1 – WWS 303.2 ......... 12 WWS 405 – WWS 405.2........13 WWS 507 – WWS 507.2 ........14 WWS 806 –...
  • Page 4: Intended Use

    ● Water/water heat pumps person has already worked with such a unit or a similar unit or has been trained by the manufacturer. ● WWS 121 is only allowed with WWB 21 Personnel qualifications CAUTION The electrical conductivity of the domestic hot All instructions and information in this operating manu- water must be >...
  • Page 5: Customer Service

    Customer service Scope of delivery For technical information please contact your local Domestic hot water storage tank enamelled to DIN heating engineer or the manufacturer's local partner. 4753 with smooth tube heat exchanger designed especially for heat pumps, integrated corrosion protection anode and 1 sensor for the heating and ...
  • Page 6: Transport, Installation, Mounting

    Transport, Installation, Mounting Mounting CAUTION Observe the following when performing all work: With our domestic-hot-water tanks, the follow- ing plastic protective components can be de- ployed on and in the connections: CAUTION ● Plastic plugs for internal threads (Protect the The tank must be installed in a frostproof threads and must be removed during installation.
  • Page 7 Assembling the earth cable for the protective CAUTION! anodes Do not exceed the operating pressures (only WWS 806 – 1006, SWWS 806 – 1008) specified on the rating plate. If necessary, install a pressure reducer. CAUTION The protective anodes (included in the scope NOTE of delivery) must be installed by the customer Close off any connections not required with...
  • Page 8: Installation Of The Sensor For The Heating And The Heat Pump Regulator

    Commissioning Installation of the sensor for the heating and the heat pump regulator Flush and fill the domestic hot water circuit and Depending on the unit model, you must install the heat exchanger before commissioning. sensor included in the scope of supply for the heating and heat pump controller on site in of the sensor ...
  • Page 9: Insulation Of The Connections And The Storage Tank

    Insulation of the connections and the storage tank NOTE Insulate in accordance with applicable local standards and guidelines/directives. Check all hydraulic connections for leaks. Perform leak test. Insulate all connections and pipes. NOTE The function of the pressure relief device must be checked at regular intervals.
  • Page 10: Technical Data

    Technical Data Tank name WWS 121 WWS 202 Type Domestic hot water tank ı Solar domestic hot water tank • ı — • ı — Hot water tank Energy efficiency class according to ErP … Standing loss according to ErP (at 65°C)
  • Page 11: Wwsb 202

    Technical Data Tank name WWSB 202 Type Domestic hot water tank ı Solar domestic hot water tank • ı — Hot water tank Energy efficiency class according to ErP … Standing loss according to ErP (at 65°C) Tank volume according to ErP Nominal capacity Max.
  • Page 12: Wws 303.1 - Wws 303.2

    Technical Data Tank name WWS 303.1 WWS 303.2 Type Domestic hot water tank ı Solar domestic hot water tank • ı — • ı — Hot water tank Energy efficiency class according to ErP … Standing loss according to ErP (at 65°C) Tank volume according to ErP Nominal capacity Max.
  • Page 13: Wws 405 Wws 405.2

    Technical Data Tank name WWS 405 WWS 405.2 Type Domestic hot water tank ı Solar domestic hot water tank • ı — • ı — Hot water tank Energy efficiency class according to ErP … Standing loss according to ErP (at 65°C) Tank volume according to ErP Nominal capacity Max.
  • Page 14: Wws 507 Wws 507.2

    Technical Data Tank name WWS 507 WWS 507.2 Type Domestic hot water tank ı Solar domestic hot water tank • ı — • ı — Hot water tank Energy efficiency class according to ErP … Standing loss according to ErP (at 65°C) Tank volume according to ErP Nominal capacity Max.
  • Page 15: Wws 806 Wws 1006

    Technical Data Tank name WWS 806 WWS 1006 Type Domestic hot water tank ı Solar domestic hot water tank • ı — • ı — Hot water tank Energy efficiency class according to ErP … — — Standing loss according to ErP (at 65°C) Tank volume according to ErP Nominal capacity Max.
  • Page 16: Swws 404 Swws 404.2

    Technical Data Tank name SWWS 404 SWWS 404.2 Type Domestic hot water tank ı Solar domestic hot water tank • ı • • ı • Hot water tank Energy efficiency class according to ErP … Standing loss according to ErP (at 65°C) Tank volume according to ErP Nominal capacity Max.
  • Page 17: Swws 506 Swws 506.2

    Technical Data Tank name SWWS 506 SWWS 506.2 Type Domestic hot water tank ı Solar domestic hot water tank • ı • • ı • Hot water tank Energy efficiency class according to ErP … Standing loss according to ErP (at 65°C) Tank volume according to ErP Nominal capacity Max.
  • Page 18: Swws 806 Swws 1008

    Technical Data Tank name SWWS 806 SWWS 1008 Type Domestic hot water tank ı Solar domestic hot water tank • ı • • ı • Hot water tank Energy efficiency class according to ErP … — — Standing loss according to ErP (at 65°C) Tank volume according to ErP Nominal capacity Max.
  • Page 19 Subject to change without notice | 83018600hUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 20: Installation Plans

    WWS 121 Installation plan > 20 > 740 > 200 Legende: DE819423 Keys: UK819423 Technische Änderungen vorbehalten. All dimensions in mm. Alle Maße in mm. Pos. Name OKF Oberkante Fertigfussboden > 20 Free space for service purposes Freiraum für Servicezwecke...
  • Page 21: Dimensonal Drawings Wws 121

    Dimensonal drawings WWS 121 Keys: UK819422b Legende: DE819422b All dimensions in mm. Technische Änderungen vorbehalten. Pos. Name Nominal volume Net weight Alle Maße in mm. Front view 115 litres 69 kg Side view from right Vorderansicht Top view Seitenansicht von rechts...
  • Page 22: Wws 202, Wwsb 202

    WWS 202, WWSB 202 Dimensonal drawings 1260 1194 1017 Legende: DE819394b Keys: UK819394 Technische Änderungen vorbehalten. All dimensions in mm. Alle Maße in mm. Smooth tube heat exchanger Name Nominal volume Net weight Tilted height Hot water circuit WWS 202 184 litres 80 kg 1380...
  • Page 23: Wws 303.1, Wws 303.2

    Dimensonal drawings WWS 303.1, WWS 303.2, WWS 405, WWS 405.2, WWS 507, WWS 507.2 Keys: UK819291d All dimensions in mm. Nominal Tilted Smooth tube heat exchanger Name volume Net weight height Hot water circuit Ø D WWS 303.1 276 litres 135 kg 1440 3.50 m²...
  • Page 24: Wws 806, Wws 1006

    WWS 806, WWS 1006 Dimensonal drawings Keys: UK819394 All dimensions in mm. Smooth tube heat exchanger 819338c Name Nominal volume Net weight Tilted height (without insulation) Hot water circuit Technische Änderungen vorbehalten Alle Maße in mm WWS 806 790 litres 290 kg 2020 5.6 m²...
  • Page 25: Swws 404, Swws 404.2

    Dimensonal drawings SWWS 404, SWWS 404.2 Keys: UK819305c All dimensions in mm. Smooth tube heat exchanger Name Nominal volume Net weight Tilted height Hot water circuit Solar circuit SWWS 404 344 litres 185 kg 1710 3.50 m² 1.62 m² SWWS 404.2 344 litres 190 kg 1720...
  • Page 26: Swws 506, Swws 506.2

    SWWS 506, SWWS 506.2 Dimensonal drawings Keys: UK819305c All dimensions in mm. Smooth tube heat exchanger Name Nominal volume Net weight Tilted height Hot water circuit Solar circuit SWWS 506 425 litres 210 kg 2020 4.30 m² 1.85 m² SWWS 506.2 425 litres 215 kg 2030...
  • Page 27: Swws 806 Swws 1008

    Dimensonal drawings SWWS 806, SWWS 1008 819339c Keys: UK819339c Technische Änderungen vorbehalten All dimensions in mm. Alle Maße in mm Smooth tube heat exchanger Name Nominal volume Net weight Tilted height (without insulation) Hot water circuit Solar circuit SWWS SWWS Pos.
  • Page 28: Connection Instructions

    Domestic hot water tank Connection instruction Keys: UK830032b Pos. Name Shut-off valve Pressure reducing valve Test valve Backflow preventer Pressure gauge connection socket Drain valve Safety valve Ventilation Shut-off valve with draining Check valve Storage tank charge pump Solar charge pump NOTE Circulation pump The positions of the individual connections...
  • Page 29: Solar Domestic Hot Water Tank

    Connection instruction Solar domestic hot water tank Keys: UK830032b Pos. Name Shut-off valve Pressure reducing valve Test valve Backflow preventer Pressure gauge connection socket Drain valve Safety valve Ventilation Shut-off valve with draining Check valve Storage tank charge pump Solar charge pump Circulation pump Cold water connection (to DIN 1988) Scald protection...
  • Page 30 Subject to change without notice | 83018600hUK – Translation of the original operating manual | ait-deutschland GmbH...
  • Page 31: Ec Declaration Of Conformity

    In the event of modification of the device(s) without our approval, this declaration shall become invalid. Designation of the device(s) Buffer storage tank / Domestic hot water tank Unit model Number Unit model Number WWS 121 15077201 WPS 61 15085501 WWS 202 15069801 WTPSK 100...
  • Page 32 ait-deutschland GmbH Industriestraße 3 D-95359 Kasendorf www.ait-deutschland.eu...

Table of Contents