Page 1
Operati ng Manual DOMESTIC HOT WATER TANK SOLAR DOMESTIC HOT WATER TANK Accessories for heat pumps We reserve the right to modify technical specifications without prior notice. 83018600gUK – translation of the operating manual...
Please read first Symbols This operating manual provides important information The following symbols are used in the operating manual. on handling the unit. It is an integral part of the product They have the following meaning: and must be stored so that it is accessible in the immediate vicinity of the unit.
Use of electric heating elements is only allowed up to CAUTION! 14°dH Have the magnesium anode checked and if necessary renewed by the customer service B 202 303.1 for the first time after 2 years and then at EHZI 45 n.g.
TRANSPORT TO INSTALLATION LOCATION • Plastic plugs for internal threads (Protect the threads and must be removed during installation. To avoid damage during transport, transport the For connections which are not required, they storage tank (secured on the wooden pallet) to its final must be replaced with pressure-resistant plugs): installation location using a lifting truck.
CAUTION! NOTE Do not exceed the operating pressures In case of installation of the solar circuit with si- specified on the rating plate. If necessary, multaneously installed electric heating element the install a pressure reducer. maximum storage tank temperature must be set so that the safety temperature limiter (overheat cut-off device) does not trip.
Technical Data Manufacturer: ait-deutschland GmbH Tank name Type Domestic hot water tank ı Solar domestic hot water tank Hot water tank: Energy efficiency class according to ErP … Standing loss according to ErP (at 65°C) Tank volume according to ErP Nominal capacity Max.
Technical Data WWS, SWWS Manufacturer: ait-deutschland GmbH Tank name Type Domestic hot water tank ı Solar domestic hot water tank Hot water tank: Energy efficiency class according to ErP … Standing loss according to ErP (at 65°C) Tank volume according to ErP Nominal capacity Max.
Page 11
WWS 806 WWS 1006 SWWS 404 SWWS 506 SWWS 806 SWWS 1008 • ı — • ı — • ı • • ı • • ı • • ı • — — — — DIN 4753 DIN 4753 DIN 4753 DIN 4753 DIN 4753 DIN 4753...
Page 12
Installation plan WWS 121 > 20 > 740 > 200 Legende: DE819423 Legende: DE819423 All dimensions in mm. Technische Änderungen vorbehalten. We reserve the right to modify technical specifications without Alle Maße in mm. prior notice OKF Oberkante Fertigfussboden > 20 Finished floor level Freiraum für Servicezwecke...
Dimensioned drawings WWS 121 Legende: DE819422b Technische Änderungen vorbehalten. Alle Maße in mm. Vorderansicht Legende: DE819422b Seitenansicht von rechts Draufsicht Front view Rückansicht Side view from right Plan view Rear view Item Name Dim. Nominal volume Net weight Hot water G3/4"...
Dimensioned drawings WWS 202 / WWSB 202 1260 1194 1017 Legende: DE819394b Legend: EN819394 Technische Änderungen vorbehalten. We reserve the right to modify technical specifications without prior notice. Alle Maße in mm. Dimensions in mm Item Designation Dim. Cold water / draining R 1"...
WWS 806 – WWS 1006 Dimensioned drawings 819338c Item Name Dim. Domestic hot water R 2" IG Circulation R 1" IG Heating water inlet R 1 1/4" IG Heating water outlet R 1 1/4" IG WWS 806 WWS 1006 Cold water R 2"...
SWWS 404 Dimensioned drawings 1628 1593 1525 1240 1035 Legend: EN819305b All dimensions in mm. Item Designation Dim. Cold water / draining R 1 1/4" AG Solar, return R 1 1/4" IG Sensor pocket for solar sensor Ø i 14 Solar, flow R 1 1/4"...
Dimensioned drawings SWWS 506 Legend: EN819065d All dimensions in mm. Item Designation Dim. Cold water / draining R 1 1/4" AG Solar, return R 1 1/4" IG Sensor pocket for solar sensor Ø i 14 Solar, flow R 1 1/4" IG Heating water, return R 1 1/4"...
Connection instructions Solar domestic hot water tank Legend: EN830032b Designation Shut-off valve Pressure reducing valve Test valve Backflow preventer Pressure gauge connection socket Drain valve Safety valve Ventilation Shut-off valve with draining Kaltwasseranschluss nach Check valve DIN 1988 Storage tank charge pump Solar charge pump 830032b Circulation pump...
Page 22
We reserve the right to modify technical specifications without prior notice. 83018600gUK – translation of the operating manual...
EC directives, the EC safety standards and the product-specific EC standards. In the event of modification of the device(s) without our approval, this declaration shall become invalid. Designation of the device(s) Unit model Number Unit model Number WWS 121 15077201 SBWS 300 15032901 WWS 202 15069801 SBWS 400 15033001...