User Manual PLUS+1® Compliant IX012-010 Function Block Contents IX012-010 Function Block Configure CAN....................................4 Inputs – Power Supply..................................5 Inputs – CAN Shield..................................5 Inputs – Sensor Power ................................... 6 Inputs – Multifunction Inputs..............................6 Inputs – Analog Inputs................................... 7 Inputs – CAN.......................................7 Connections and Signal Overview.............................
User Manual PLUS+1® Compliant IX012-010 Function Block IX012-010 Function Block The IO_Module function block enables communication with the IX012-010 expansion module so the module's additional inputs and outputs can be used. Configure CAN Set up CAN so that CAN messages can be transmitted to and from the I/O module.
User Manual PLUS+1® Compliant IX012-010 Function Block IX012-010 Function Block Input Type Range Description Enbl_RecheckCRC BOOL —— Determines if the I/O module CRC is periodically checked to ensure the device’s configuration matches the function block’s configuration. T: The CRC is requested from the I/O module and compared every 5 seconds.
User Manual PLUS+1® Compliant IX012-010 Function Block IX012-010 Function Block Inputs – Sensor Power The status of sensor power input on the connector and pin C1p06 is described. Signal Type Direction Range Description C1p06_SnsrPwr —— —— AnIn U16 Input 0 – 32767 Analog input AD count.
User Manual PLUS+1® Compliant IX012-010 Function Block IX012-010 Function Block Signal Type Direction Range Description AnIn_Updated BOOL Input —— True when the DigIn, AnIn and Volt signals are refreshed. Freq_Updated BOOL Input —— True when the Freq signal is refreshed.
User Manual PLUS+1® Compliant IX012-010 Function Block IX012-010 Function Block Signal Type Direction Range Description Incompat_Protocl BOOL Input —— The responding hardware uses an incompatible version of the I/O protocol. Update the firmware running on the hardware, or use a newer version of the function block for proper communication.
User Manual PLUS+1® Compliant IX012-010 Function Block IX012-010 Function Block Configuring Communications The parameters that control the communication between a controller and an I/O module are described. Variable Addressing Mode Variable addressing mode is the default addressing mode of the I/O module, but it is not the default mode for the function block.
User Manual PLUS+1® Compliant IX012-010 Function Block IX012-010 Function Block Non-Volatile Parameters After volatile parameters are configured, the function block sends a request for the configuration CRC to the I/O module. If this number matches the locally calculated value, then the configurations stored on the I/O module match those set in the function block.
User Manual PLUS+1® Compliant IX012-010 Function Block IX012-010 Function Block Troubleshooting Find out how to ensure the outputs of the I/O module function properly, and make sure your changes to parameters are saved. Problem Cause Solution Outputs of I/O module do not...
Page 12
Phone: +86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed.