Download Print this page
HANYOUNG NUX ML-D Series Instruction Manual

HANYOUNG NUX ML-D Series Instruction Manual

Module type temperature controller
Hide thumbs Also See for ML-D Series:

Advertisement

Quick Links

Module type temperature controller
ML-D
series
INSTRUCTION MANUAL
Thank you for purchasing HANYOUNG product.
Please check whether the product is exactly the same as you ordered.
Before using the product, please read this instruction manual carefully.
Please keep this manual where you can view at any time.
※ Please refer to the ML-D☐ Instruction Manual for the specific explanation about "Installation and wiring". Also, refer to ML-D☐'s
user Manual in the website for a detailed information.

Safety information

Alerts declared in the manual are classified to Danger, Warning and Caution by their criticality
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
WARNING
•If the user uses the product with methods other than specified by the manufacturer,
it may occur serious injuries or property damages.
• If you are concerned about serious accident due to the malfunction of products,
please install safety circuit outside.
•To prevent from the electric shock and the product's malfunction,
install and assemble it after turning off the power.
•To protect from electric shock and malfunction of the device, do not turn Power "ON" until all wiring
is finished. Also, check-out if the wiring is correct before turning power "ON" for this product.
CAUTION
Safety
•For the safety and protection of the product and the system connected to it, please follow the manual and use it.
•We do not have responsibility for all the damages caused by using the products
without following the introductions in the manual or careless use of it.
•For the safety and protection of the product and the system connected to it,
you must install a separate circuit outside the product when you are required.
•Do not dissemble, repair and remodel it as you pleases. It may cause electric shock, fire and malfunction.
•Do not give a shock to the product. It may cause damage and malfunction of the product.
•We do not have responsibility and guarantee about the product for any of the contents
other than the terms of our company's quality assurance.
•When a user or others are harmed by the defection which is unexpected by our company or natural
disaster while using the product, we do not have any responsibility for the loss or indirect damage.
Installation
• Use it after installing the product on panel since there is a risk of electric shock.
• Do not block radiators of the product. It may cause malfunction of the product.
• Do not install it in following places :
· The place for contacting the part while people are unconscious.
· A place where there is a direct electric vibration or shock.
· A place where there is a corrosive gas or a combustional gas.
· A place where there is a high temperature change.
· A place where the temperature is extremely high or low.
· A place where there is a direct sunlight.
· A place where there is a high impact of electromagnetic waves.
· A place where there is a high humidity.
· A place where there are products that are highly flammable in case of fire.
· A place where there is a lot of dust and salt.
Wiring
• Wire it after all the powers of the instruments are shut off.
•It works at 24 V DC. When using a power other than the rating, it may cause an electric shock and fire.
•When connecting many of ML Series to make one module, connect a power to only one unit.
• When connecting to 24 V DC power, use it in accordance with the rating after calculating total
consumption of electric power. Using a power supply of lower capacity than the total
consumption of electric power of the module may cause malfunction of the product.
• Do not work with wet hand. It may cause electric shock.
• For installation and way of use, use the manual and follow it.
• Refer to the installation method for the content and about the connection. Never connect to
gas pipe, telephone wire, and lighting rod. It may cause explosion and fire.
•Do not supply power before finishing the connections among the parts of this product.
• There is a possibility of electric shock while applying electric current. So, do not come in contacts with any parts.
• For I/O signal line, wire it after separating the instrument's power line and load line to
prevent the impact of induction noise.
•For instrument's power, wire it to avoid a noise impact from the power. We recommend
to use noise filter if it is easy to get impact of the noise.
•For connected module's power supply, supply it to only one module. Power is supplied
among all connected modules.
•For power, select the product in accordance with inrush current when the connected
module's consumption voltage and Power are ON.
█ Loder cable
•Be sure to use the cable supplied by the manufacture. Connecting another cable such as
a general USB cable may cause malfunction.
█ Customer Support
•The guarantee period is 1 year from the date of purchasing the product. When we would find
any malfunction of the product since you use it normally by the manual, we would repair it for free.
•The cost of repair after the guarantee period will be expensed according to our company's standard.
•The costs of the repair for malfunction during the guarantee period are expensed as follows :
· Malfunction by user's mistake.
· Malfunction by natural disasters.
· Malfunction by moving after the product is installed.
· Malfunction by a change of the product randomly or damage.
· Malfunction by disorder of power supply due to unstable power supply.
•Please contact our company's sales team or distributor when you need the A/S for malfunction or etc.
HEAD OFFICE
HANYOUNGNUX CO.,LTD
28, Gilpa-ro 71beon-gil, Nam-gu, Incheon, Korea
TEL : (82-32)876-4697
FAX : (82-32)876-4696
http://www.hynux.com
Suffix code
█ ML-D4
Model
Code
ML-D
4 Channles temperature controller
M
Relay output
Output type
S
SSR Output (12 V DC)
C
SCR Output (4 - 20 ㎃ DC)
█ ML-D2H
Model
Code
ML
D2H
2 Channels Heating/Cooling control
MM OUT1 : Relay / OUT2 : Relay
SM OUT1 : SSR / OUT2 : Relay
Output type
SS
OUT1 : SSR / OUT2 : SSR
CM OUT1 : 4 - 20 mA d.c. / OUT2 : Relay
CS
OUT1 : 4 - 20 mA d.c. / OUT2 : SSR
Checking products
Check the following items with the package.
Main body
4 parts for 6 pin terminal

Part names and functions

█ ML-D2H
NO
█ ML-D4
NO
* When unit expansion address switch is located at +16 and unit address switch
is located at 1 then, RS485 communication address is set up like 1+16=17.
3
MA0617KE161214
Information
Information
1 part for 5 pin terminal
Name
Function
Power, Communication, Event,
LED status display
Control output display LED
Loader Jack
RS232C communication input part
Unit address switch RS485 communication address setting switch (0~15)
Unit expansion
RS485 communication expansion address
address switch
setting switch (0/+16)*
Temperature input and CT input part
CH1 Part
OUT1: Heating control output part
OUT2: Cooling control output part
Temperature input and CT input part
OUT1: Heating control output part
CH2 Part
OUT2: Cooling control output part
Power and
communication part RS485 communication and 24V DC input part
Name
Function
Power, Communication, Event,
LED status display
Control output display LED
Loader Jack
RS232C communication input part
RS485 communication address
Unit address switch
setting switch (0 ~ 15)
Unit expansion
RS485 communication expansion address
address switch
setting switch (0 / +16)*
CH1 Part
CH2 Part
Temperature input and
contact output part
CH3 Part
CH4 Part
Power and
RS485 communication and
communication part
24 V DC input part

Advertisement

loading

Summary of Contents for HANYOUNG NUX ML-D Series

  • Page 1: Safety Information

    MA0617KE161214 Module type temperature controller ML-D series INSTRUCTION MANUAL HEAD OFFICE HANYOUNGNUX CO.,LTD Thank you for purchasing HANYOUNG product. Please check whether the product is exactly the same as you ordered. 28, Gilpa-ro 71beon-gil, Nam-gu, Incheon, Korea TEL : (82-32)876-4697 FAX : (82-32)876-4696 Before using the product, please read this instruction manual carefully.
  • Page 2 Dimension and connection diagram Specification ● Quality 96.90 87.00 9.90 6.00 30.00 Display range ±0.3% of Input range, ±1 Digit 13.75 1.50 Insulation resistance Over 500 V DC 20 MΩ (For Power and input part) ML-D4 Withstand voltage 750 V AC (For power and input part) ●...

This manual is also suitable for:

Ml-d2hMl-d4