KDP TIMER SEQUENCE CHART
KDP RINSE/HOLD CYCLE PROGRAM
PL
-
·~322
I
Tim
e
lg
"
0
NQ
~
-
0
"
~
~
c
~~
-
0
0
-
-
~
~~
_..,
P
e
r
To
tal
Elapse
d
:.
0
.
-=-
.5
~
"
Ev
e
nt
a
t End of
E<
0.
~
~
~
§
a
g..:i
..:i
..:i
Ev
e
nt
Eve
nt
~~
H
f=ci
0. ..
iri~O::O
Min
.
Sec
.
Mi n.
Sec.
RAPID ADVA
NC
E
XX
X
X
0
30
0
30
PU
MP
X
X
X
0
15
0
45
FILL
X
X X
X
1
30
2
15
PUMP
X
X
X
0
32
2
47
RAPID ADVA
NCE
X X X
X
0
3
2
50
P UMP
X
X
X
0
15
3
5
DRAI
N
X
X
X
X
0
55
4
0
P UMP
X
X
X
0
20
4
20
PUMP OFF
X
X
0
52
5
12
P UMP
X
X
X
0
30
5
42
DRAIN
SCAVE
NG
ER
X
X
X
X
0
30
6
12
P UMP
X
X
X
0
18
6
30
PUMP OFF
X
X
0
15
6
45
RAPID ADVA NCE
X X
X
0
25
7
10
DWELL
X
0
23
7
33
RESET
X
0
3'
*Whe
n
Door
Unlatc
hed
KDP SHORT WASH CYCLE PROGRAM
P
L
-1~
32,
J
Time
ci.
"
B
!l
~~
"
-
N"'
0
"
"'"'
-
]
:3
o.s
g
g.~
P
e
r
Total
Elapsed
:.
0
-=-
=
Q
c
~
"
Eve
nt
at E
nd
of
0.
~
Event
Event
E<
e-
~~
.;
~
~...:i
..;i
,j
~0::
0
:;:
~=
lii
;i.:o
....
Min.
Sec.
Mi n.
Sec
.
PU MP
X
X
X
0
13
0
13
F1LL, 1ST
PREWASH
X
X
X
X
1
18
1
31
PUMP
X
X
X
0
23
1
54
RAPID ADVANCE
X
X
X
X
0
3
1
57
DET. D!SP.
HI
X
X
X
PUMP
X
X
X
1
1
4
3
RAPID ADVA NCE
XX
X
X
0
15
4
47
PUMP
X
X
X
0
15
5
2
DRAIN
X
PUMP
X
X
X
0
38
6
40
F1
LL MAI
N
WASH
X
XX
X
1
30
8
10
DET. D!SP.
12
X
X
X
X
1
30
8
56
PUMP
X
X
X
0
2
1
9
17
RAPID ADVANCE
XXX
X
0
3
9
20
P
UMP
X
X
X
0
4
44
DRA IN
X
X
X
X
1
0
10
44
PUMP
X
X
X
0
40
11
24
FILL
1ST AFTER RINSE
X
XX
X
1
30
12
54
PUMP
X
X
X
0
34
13
28
RAPID ADVANCE
X
XX
X
0
3
13
31
UMP
X
X
0
15
13
46
DRAIN
X
X
X
X
1
0
14
46
PUMP
X
X
X
0
39
15
F1LL
,
2ND
AFT ER
RINSE
X
XX
X
1
18
16
43
RINSE
GENT DISP
.
X
X
X
X
1
30
17
4
P
UM
P
X
X
X
0
46
18
33
DRAI
N
X
X
X
X
0
55
19
28
PUMP
X
X
X
0
20
19
48
PUMP OFF
X
X
0
52
20
40
UMP
X
X
0
30
21
10
DRAIN SCAVENGE
R
X
X
X
X
0
30
21
40
PUM
P
X
X
0
18
21
58
P
UMP OFF
X
X
0
51
22
49
BLOWER ON
X
X
X
0
11
23
0
AI
R HEAT
&
BLOWE
R
X
XX
22
1
45
1
BLOWER
X
13
21
58
22
DWELL
X
0
43
59
5
R
ESET
X
0
3'
*Whe
n
Door
Unlatc he
d
-
41 -
p
R
0
G
R
E
s
s
!
!
l
p
R
0
G
R
E
s
s
j
j
j
These charts sho
w which com-
ponents are
energized and should
be
fun
ctioning during
each period
o
f
the
program
cy
cle.
REMEMBER:
In addition
to the
timer,
certain other
switches also
control
the
electri cal
po
wer sup
ply.
These are:
(1)
the
door
interlock
switch
, (2) the
over fill control
switch,
(3)
the
program switch
and, ( 4) the
various
thermostats
and
thermal
protectors.
NOTE:
On
the
KDP
model,
the
timer
should
be manually
advanced
ONLY
by removing the
dial from the tool
(TL-72
139) and
placing the
pointer-
like
hub on the
timer
shaft
,
then
rotating
the
hub
slowly clockwise
to
the
desired
position.
The
pointer on
the
hub will
indicate the cycle phase
in which
the
timer is
operating by
pointing to that portion of the dial
which is
already