In the Calibration screen touch and release each target shown.
(Four calibration targets and two verification targets). Each must
be completed within 15 seconds or the Calibration Time out
message is shown. The unit returns to the main screen.
6.
If normal operation is desired cycle power to the unit or tap the
Reboot text on the main screen followed by tapping the Main App
> text to perform a warm startup.
7.
When in normal operation check that the touch screen accuracy
has improved. If the accuracy has not improved, try the calibration
procedure again. If the issue continues contact L-3 Avionics
Systems Field Service for help in resolving the issue prior to
removing the unit for repair.