Chapter 3. Detailed Description Of Screens/Functions; Boiler; Set Target Temperature And Operating Mode; Settings - Estyma IGNEO Touch User Manual

Eg-pellet
Hide thumbs Also See for IGNEO Touch:
Table of Contents

Advertisement

IGNEO
touch user manual
Chapter 3.
3.1
B
OILER
3.1.1

SET TARGET TEMPERATURE AND OPERATING MODE

The following table presents available boiler operating modes.
SYMBOL
NAME
manual
automatic
time- manual
time- automatic
3.1.2

SETTINGS

NAME
Set temperature [°C]
Switching hysteresis [°C]
Hysteresis exemption [°C]
10
Detailed description of screens/functions
The boiler temperature is set directly by the user. The boiler works to maintain the
set target temperature.
The boiler temperature is set automatically on the basis of the current need of the
heating circuits, hot water circuits or the buffer.
When there's no need to heat the water, the temperature will be set to minimum
of 7°C (antifreeze mode), and the boiler will turn on only when needed.
The boiler temperature is set as in the manual mode, but the boiler can work only
in set time limits.
The boiler temperature is set as in the automatic mode, but the boiler can work
only in set time limits.
The set temperature in manual or time manual mode.
The burner is turned on when the temperature in the boiler is lower than the set
temperature, minus the switching hysteresis.
The burner is turned off if the temperature in the boiler is higher than the set
temperature plus hysteriesis exemption.
EGP -EN 20171024
Boiler target set temperature and operating mode can be
regulated after pressing number ''6'' on the main screen.
DESCRIPTION
DESCRIPTION
www.estyma.pl