Advertisement

Quick Links

www.pce-group-europe.com
Made in Europe
USER MANUAL
AB-SERIES 100 / 200
PCE-Group: ba-analysenwaage-pce-ab-100-GB
PCE Deutschland GmbH&Co.KG
Im Langel 4
Deutschland
D-59872 Meschede
Tel: 029 03 976 99-0
Fax: 029 03 976 99-29
info@warensortiment.de
www.pce-group-europe.com

Advertisement

Table of Contents
loading

Summary of Contents for PCE Group AB Series

  • Page 1 www.pce-group-europe.com PCE Deutschland GmbH&Co.KG Im Langel 4 Deutschland D-59872 Meschede Tel: 029 03 976 99-0 Fax: 029 03 976 99-29 info@warensortiment.de www.pce-group-europe.com Made in Europe USER MANUAL AB-SERIES 100 / 200 PCE-Group: ba-analysenwaage-pce-ab-100-GB...
  • Page 2: Table Of Contents

    USER MANUAL ____________________________________________________________________________________________________________________ www.pce-group-europe.com Contents: General description................3 Technical data..................4 Completeness ..................4 Security rules ..................5 Keys and indicators................6 Preparations – working environment ..........7 Preparation – the balance..............8 Operation principles ................9 Start-up and user menu ..............10 Pieces counting function ..............11 9.1.1. Counting with reference sample .............11 9.1.2.
  • Page 3: General Description

    ____________________________________________________________________________________________________________________ ww.pce-group-europe.com 1. General description AB series balances are destined for high accuracy weighing in laboratory practice.Balances are equipped with internal calibration system for proper accuracy control during operation. The user should also own weight standard of OIML E2 class for periodical control of the balance (weight value stated in Technical Data sheet) - available separatelly.
  • Page 4: Technical Data

    USER MANUAL ____________________________________________________________________________________________________________________ www.pce-group-europe.com 2. Technical data Type PCE-AB-100 PCE-AB-200 Capacity (Max) 100 g 200 g Min load (Min) 100 mg 100 mg Reading unit (d) 0,1mg 0,1mg Verification unit (e) Tare range -100 g -200 g Accuracy class +18 ÷ +33 °C Working temperature Weighing time...
  • Page 5: Security Rules

    USER MANUAL ____________________________________________________________________________________________________________________ ww.pce-group-europe.com 4. Security rules To avoid electrical shock or damage of the balance or connected peripheral devices, it is necessary to follow the security rules below. • All repairs and necessary regulations can be made by authorised personnel only.
  • Page 6: Keys And Indicators

    USER MANUAL ____________________________________________________________________________________________________________________ www.pce-group-europe.com 5. Keys and indicators 100% → ← keys tare (subtract package weight from weighed mass) switch-off (standby), ENTER confirm decimal point, 1/F1 ... 5/F5 - numeric / functional keys, → ← numeric key / zeroing (balances for direct sale use only), numeric key / data output (print / transmission), numeric key / internal calibration,...
  • Page 7: Preparations - Working Environment

    USER MANUAL ____________________________________________________________________________________________________________________ ww.pce-group-europe.com 6. Preparations – working environment +33°C +18°C When choosing a location to set up the balance, remember the following rules to ensure proper working conditions and user-friendly operating: setup the balance on an even, flat surface leaving neccesary room for easy acces, maintain proper working temperature, avoid strong air drafts, vibrations, dust, big temperature changes and humidity over 90%,...
  • Page 8: Preparation - The Balance

    USER MANUAL ____________________________________________________________________________________________________________________ www.pce-group-europe.com 7. Preparation – the balance 1. Take the balance and supplied accessories (a feeder, pan elements) out of the box. 2. Place the balance on a stable ground not affected by mechanical vibrations and airflows. 3. Level the balance with rotating rear legs so that the air bubble in water-level at the back of the balance is in the middle.
  • Page 9: Operation Principles

    USER MANUAL ____________________________________________________________________________________________________________________ ww.pce-group-europe.com 8. Operation principles 1. To ensure proper weighing accuracy the balance is equipped with internal calibaration system. The system automatically calibrates the balance every 2 hours and with temperature changes (more than 1°C) without user ingerence. Nevertheless, it is advised to check balance accuracy with weight standard (or other object with known weight) before and after each series of measurements.
  • Page 10: Start-Up And User Menu

    USER MANUAL ____________________________________________________________________________________________________________________ www.pce-group-europe.com 9. Start-up and user menu INICJALIZATION program version After switching-on, the balance performs Processor automatic self-test. Each test must be EEPROM accepted and confirmed with mark. AUTOMATIC CALIBRATION After self-test the balance proceeds with internal calibration mode as described in Internal calibration chapter 10.
  • Page 11: Pieces Counting Function

    USER MANUAL ____________________________________________________________________________________________________________________ ww.pce-group-europe.com Pieces counting function 9.1.1. Counting with reference sample Max ... Min ... e= ... d= .. Place a reference sample with known number of pieces on the pan. 2.000 100% Press Menu key to enter the user function USER FUNCTIONS menu, chose Counting with the cursor and press ENTER key.
  • Page 12: Counting With Unit Weight

    USER MANUAL ____________________________________________________________________________________________________________________ www.pce-group-europe.com 9.1.2. Counting with unit weight USER FUNCTIONS Press Menu key to enter the user function Auto-tare menu, chose Counting and press ENTER Counting key. Calibration USER FUNCTIONS / Pcs Chose Unit weight option and press 1. Activate ENTER key.
  • Page 13: Auto-Tare Function

    USER MANUAL ____________________________________________________________________________________________________________________ ww.pce-group-europe.com Auto-tare function USER FUNCTIONS Press Menu key to enter the user function menu, chose Auto-tare and Autotaring press ENTER key. Counting Calibration USER FUNCTIONS / AUTO-TARE Chose Correction range and press ENTER key. 1. Activate Enter maximum zero flow...
  • Page 14: External Calibration / Calibration Options

    USER MANUAL ____________________________________________________________________________________________________________________ www.pce-group-europe.com 9.3 External calibration / calibration options External calibration in verified balance should be performed in authorised PCE-Group services, as it is possible only after removing protective seals. In this case the validity of the verification is void and the balance must be re-verified by the nearest Notified Body or at the place of installation.
  • Page 15 USER MANUAL ____________________________________________________________________________________________________________________ ww.pce-group-europe.com Calibration options: USER FUNCTIONS Press Menu key to enter the user function menu, chose Calibration with Auto-tare the cursor and press ENTER key. Counting Calibration USER FUNCTIONS / CALIBRATION Report printout enables to print current 1. Report printout calibration data.
  • Page 16: Internal Calibration

    USER MANUAL ____________________________________________________________________________________________________________________ www.pce-group-europe.com Internal calibration Internal calibration is performed automatically after each start-up, also every 2 hours and with temperature changes more than 1°C. To calibrate the balance with internal weight, simply empty the pan and press key. CALIBRATION Internal calibration in progress: Press key.
  • Page 17: Connecting The Balance With A Computer Or A Printer

    USER MANUAL ____________________________________________________________________________________________________________________ ww.pce-group-europe.com 11. Connecting the balance with a computer or a printer The balance may send data to a computer or a printer via RS232C interface. When cooperating with a computer, the balance sends weighing result after initialising signal from a computer or after pressing RxD (receiving) key.
  • Page 18: Troubleshooting And Maintenance

    USER MANUAL ____________________________________________________________________________________________________________________ www.pce-group-europe.com 12. Troubleshooting and maintenance Display indication Possible cause Remedy "Test ..." Auto-tests are being performed wait for 1 minute / electronic unit damage " - - - - " The balance is during zeroing wait for 1 minute / mechanical damage check if the balance is placed on stable ground, not affected...
  • Page 19 USER MANUAL ____________________________________________________________________________________________________________________ ww.pce-group-euro pe.com Declaration of conformity PCE Deutschland APPROVAL NO. of EC TCM 128/07-4512 (cz) Im Langel 4 Tel: 0049-[0]2903- 976 99-0 D – 59872 Meschede Fax: 0049-[0]2903-976 99-29 E-Mail: info@warensortiment.de Internet: www.pce-group-europe.com Declaration of conformity for apparatus with CE mark Konformitätserklärung für Geräte mit CE-Zeichen Déclaration de conformité...

This manual is also suitable for:

Pce-ab-100Pce-ab-200

Table of Contents