Control panel

y u
e o w q
t
r
y u
t r
e o w q

1 Overload warning lamp

2 Output indicator lamp
3 Oil warning lamp
4 Choke knob
5 Fuel petcock
6 Key switch (starter switch)
7 Economy control switch
8 DC output
9 DC breaker (NFB)
0 AC receptacles

Indicators

1
Overload warning lamp
During power generation, if a problem occurs with a connected device, there is an overload, or the inverter
control unit overheats, the electronic breaker will be activated and interrupt power output to protect the gen-
erator and/or connected devices.
➢ When the electronic breaker operates:
The engine continues to run, but the control unit stops output
The output indicator (green) turns off
The overload indicator (red) turns on
I When the overload warning light turns on:
➢ Stop the engine.
Verify the required load of the connected device, and reduce to the rated load of the generator if necessary.
Verify whether or not there is a problem with a connected device. (A possible cause of excessive current
drain.)
Check for foreign matter in the cooling air inlet and areas around the control unit which could block incom-
ing air.
➢ To return the generator to normal output operation:
Temporarily stopping the engine and re-starting automatically resets the system to its original state.
(The system cannot be reset unless power to the control unit is interrupted by stopping the engine.)
i
! 0
120 V 60 Hz (USA)
i
! 0
230 V 50 Hz (Australia)
y u
t r e
y u
t r
e ow q
y u
t r
e ow q
– 8 –
! 0
o
i
w q
120 V 60 Hz (Canada)
i
! 0
230 V 50 Hz (Europe)
i
! 0
230 V 50Hz

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ef3000iseb

Table of Contents