7.0 INITIAL STARTUP

Press the Power Button on the Control Pendant until
'ON' appears on the display to enable loading.
IF a material demand exists, the loader will begin
loading.
NO LOAD ALARM FUNCTION
The NO LOAD ALARM is enabled through the control
pendant by entering a display value >0
when the No Load Alarm LED is illumi-
nated (see photo).
NO LOAD ALARM occurs when the
counter reaches the user selected Alarm
Set Point value.
• The Loader continues load attempts
after the 'Alarm' Output is energized.
• If 10 cycles pass without the alarm
counter being cleared, the Loader will
shut down and flash "OF" on the pen-
dant control.
CLEARNING AN ALARM CONDITION:
• Pressing the 'Select Button' will silence the 'alarm' out-
put. The alarm counter will continue.
• The alarm clears when the hopper is full.
• After Alarm Shutdown, press the power button to clear
the alarm and restart operation.
BLOWBACK FUNCTION
Blowback, when enabled for filter cleaning, pulses before
and after any load cycle designated for blowback by the
control settings.
Blowback also pulses briefly at the beginning of each
load cycle, just as the motor begins operating. This blow-
back pulse is intended to clear any material residue from
the discharge flapper and ensure a clean vacuum seal for
optimal loading.