Problem
The swing angle
is set or normal
operation starts
after a certain period
when the
swing
button is pressed.
The indicator does
not fl ash and the fan
does not work even if
the button is pressed.
Remote Control not
working.
Fans not used for a long time should be carefully
inspected
Power cord or AC adapter heats
up abnormally.
The power turns on and off
repeatedly.
Burning smell.
Cause
This is not a failure (in
order to confi rm the
positional relationship of
the internal circuit, there
may be cases where
the operation can't be
performed immediately
or the operation exceeds
the specifi ed angle when
the swing function is
fi rst turned on.).
On timer is enabled.
The battery voltage is
low.
The battery is loaded
incorrectly.
The remote control is
installed in the storage
area during operation.
The remote control
is not pointed at the
receiver.
Too far away from the
receiver.
21
Solution
Please wait for the swing to
resume normal.
Press the timer button repeatedly
to disable the timer.
Replace the battery (page 6).
Install the battery properly (page
6).
Point at the receiver and operate in
effective range (page 6).
Please turn off the power, unplug
the AC adapter and contact
the dealer or customer service
department of OBJECTO